{"product_id":"one-danfoss-195n1041-vlt2815pt4b20str0dbf10a00-inverter-qw","title":"ONE Danfoss 195N1041 VLT2815PT4B20STR0DBF10A00 inverter#QW","description":"\u003c!-- ============ Hero \/ Intro ============ --\u003e\n\u003ch1 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:28px; line-height:36px; margin:0 0 8px 0;\"\u003e\n  Danfoss 195N1041 VLT2815PT4B20STR0DBF10A00 — VLT 2800 Series 1.5 kW Compact AC Drive\n\u003c\/h1\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#0056B3; font-size:14px; line-height:22px; letter-spacing:1px; text-transform:uppercase; margin:0 0 24px 0;\"\u003e\n  Danfoss · VLT 2800 · VFD \/ Inverter · 1.5 kW · 3-Phase 380–480 V\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:0 0 16px 0;\"\u003e\n  The \u003cstrong\u003eDanfoss 195N1041 (VLT2815PT4B20STR0DBF10A00)\u003c\/strong\u003e is a 1.5 kW compact\n  \u003ca href=\"\/ar\/collections\/factory-automation\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAC drive\u003c\/a\u003e\n  from the \u003ca href=\"\/ar\/collections\/danfoss\" style=\"color:#0056B3; text-decoration:underline;\"\u003eDanfoss\u003c\/a\u003e\n  VLT 2800 family, designed for 3-phase 380–480 V industrial mains. It integrates a\n  built-in RFI filter, an integrated brake chopper, RS-485 Modbus RTU communication\n  and a removable \u003ca href=\"\/ar\/products\/danfoss-lcp-2-control-panel\" style=\"color:#0056B3; text-decoration:underline;\"\u003eLCP local control panel\u003c\/a\u003e,\n  making it a workhorse for brownfield retrofits, MRO replacement and OEM machine\n  builds where compactness, reliability and easy commissioning matter more than\n  fieldbus breadth. KOEED sources the full VLT 2800 family alongside\n  \u003ca href=\"\/ar\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley PowerFlex\u003c\/a\u003e,\n  \u003ca href=\"\/ar\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens Sinamics\u003c\/a\u003e,\n  \u003ca href=\"\/ar\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi FREQROL\u003c\/a\u003e,\n  \u003ca href=\"\/ar\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron MX2 \/ RX\u003c\/a\u003e,\n  \u003ca href=\"\/ar\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc spindle drives\u003c\/a\u003e,\n  \u003ca href=\"\/ar\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider Altivar\u003c\/a\u003e,\n  \u003ca href=\"\/ar\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa V1000 \/ A1000\u003c\/a\u003e,\n  \u003ca href=\"\/ar\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic Minas\u003c\/a\u003e\n  and \u003ca href=\"\/ar\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE servo platforms\u003c\/a\u003e,\n  so multi-brand bills of materials can be quoted in one email.\n\u003c\/p\u003e\n\n\u003c!-- ============ 1. Key Technical Specifications \/ Overview ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  1. Key Technical Specifications \u0026amp; Overview\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  The full ordering code \u003cstrong\u003eVLT2815PT4B20STR0DBF10A00\u003c\/strong\u003e decodes the\n  VLT 2800 series naming convention. VLT2815 places the unit in the 1.5 kW power\n  class; the trailing “PT” denotes the \u003cem\u003ePC Tool\u003c\/em\u003e programming\n  option (VLT Motion Control Tool MCT-10). The “4” declares a\n  3-phase 380–480 V AC input, B20 adds a brake chopper and built-in RFI\n  filter, ST indicates the standard control variant, R0 means no integrated\n  display (LCP is supplied separately or shared across drives), and DBF10A00\n  packages the options suffix used by Danfoss configurators. The drive is\n  housed in a compact IP20 \/ NEMA 1 frame size A2 chassis suitable for\n  cabinet mounting, with side-by-side and book-style installation supported\n  to save panel space on dense machine layouts.\n\u003c\/p\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #eeeeee; font-family:Arial, Helvetica, sans-serif; font-size:14px; margin:0 0 24px 0;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eDanfoss (Danfoss Drives)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003ePart Number\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e195N1041\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eFull Ordering Code\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eVLT2815PT4B20STR0DBF10A00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eVLT 2800 (compact AC drive)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eModule Type\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eVFD \/ Frequency Inverter — 1.5 kW class\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eMains \/ Input\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e3-phase 380–480 V AC, 50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eContinuous Output\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e1.5 kW (2 HP) at 400 V, 3.7 A nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eOutput Frequency\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e0 – 1000 Hz (V\/f + sensorless vector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eControl Modes\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eV\/f, sensorless flux vector (open loop), process PID\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eBuilt-in Brake Chopper\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eYes (B20 option) — external brake resistor required\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eRFI \/ EMC Filter\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eIntegrated Class A1\/A2 (B20) — residential \/ industrial\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eCommunication\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eRS-485 Modbus RTU (standard); Profibus DP via option card\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eLocal Control Panel\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eLCP 2 removable (R0 = no panel bundled)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eEnclosure \/ Frame\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eIP20 \/ NEMA 1, frame size A2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eMounting\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eSide-by-side, book-style, DIN-rail adapter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eTypical Application\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003ePumps, fans, conveyors, mixers, simple hoist positioning\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eStock Status\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eIn stock — quote within 24 hours at \u003ca href=\"mailto:Moritta@KOEED.COM\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c!-- ============ 2. Application Scenarios \/ Where It Fits ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  2. Application Scenarios \u0026amp; Where It Fits\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003e\n  The VLT 2815 1.5 kW is the classic “general purpose” drive for\n  the 0.37–1.5 kW power band. It is the right pick when the load is a\n  standard induction motor in the 1–2 HP range and the user does not need\n  safety-rated STO or high-speed fieldbus. Typical deployments include:\n\u003c\/p\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  \u003cli\u003e\n\u003ca href=\"\/ar\/collections\/pumps-fans\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePumps and fans\u003c\/a\u003e — HVAC air handling units, chilled water pumps, exhaust fans; the integrated PID and skip-frequency bands suit constant-air-volume boxes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/ar\/collections\/conveyors\" style=\"color:#0056B3; text-decoration:underline;\"\u003eConveyors and material handling\u003c\/a\u003e — packaging lines, sortation, palletizers running a few hours per shift.\u003c\/li\u003e\n  \u003cli\u003eMixers, agitators and small extruder screws in food, chemical and plastics plants.\u003c\/li\u003e\n  \u003cli\u003eSimple hoist and winch positioning where the integrated brake chopper dissipates regenerative energy.\u003c\/li\u003e\n  \u003cli\u003eOEM machine builds — textile machines, washing systems, small woodworking CNCs feeding a \u003ca href=\"\/ar\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e or \u003ca href=\"\/ar\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e controller, or a \u003ca href=\"\/ar\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens SIMATIC S7\u003c\/a\u003e cell.\u003c\/li\u003e\n  \u003cli\u003eBrownfield MRO — replacing 20-year-old \u003ca href=\"\/ar\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley 1336\u003c\/a\u003e or \u003ca href=\"\/ar\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa VS mini\u003c\/a\u003e units on existing conveyors where a direct-fit compact form factor is preferred.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  The VLT 2800 family has been in continuous production for roughly a decade,\n  so it is well supported in the field, well documented, and widely understood\n  by maintenance technicians — an important consideration for plants that\n  standardise on Danfoss and need fast MRO turnaround rather than the latest\n  iC2 \/ iC7 platform.\n\u003c\/p\u003e\n\n\u003c!-- ============ 3. Integration \u0026 Wiring Notes ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  3. Integration \u0026amp; Wiring Notes\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003e\n  Power terminals follow the standard Danfoss VLT 2800 layout for the A2\n  frame: L1 \/ L2 \/ L3 for the incoming 3-phase 380–480 V mains, U \/ V \/ W\n  for the motor output, and DC+ \/ BR for the external brake resistor. Control\n  terminals include 6 digital inputs, 2 analog inputs (0–10 V or\n  0\/4–20 mA, switchable), 1 analog output, 2 relay outputs, and the\n  RS-485 Modbus RTU pair (terminals 68 \/ 69). The factory default for the\n  analog input is voltage; for current-loop setpoints from a PLC, parameter\n  group 3 must be reconfigured.\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003e\n  When tying the VLT 2815 into a multi-brand cell — for example a\n  \u003ca href=\"\/ar\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e S7-1200,\n  a \u003ca href=\"\/ar\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron CP1H\u003c\/a\u003e,\n  a \u003ca href=\"\/ar\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider Modicon M340\u003c\/a\u003e\n  or a \u003ca href=\"\/ar\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic FP-X\u003c\/a\u003e —\n  Modbus RTU on terminals 68\/69 is the simplest path. For higher-level\n  \u003ca href=\"\/ar\/pages\/modbus-crc-calculator\" style=\"color:#0056B3; text-decoration:underline;\"\u003eModbus frame generation and CRC validation\u003c\/a\u003e,\n  KOEED’s free calculator helps pre-build request frames. The drive\n  also accepts a hardware STO-style safe-stop input via the digital terminals\n  when wired per Danfoss application note MN.20.A1.01; for category 3\/PL d\n  machinery safety, an external safety relay is normally added.\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; line-height:24px; font-size:15px; margin:0 0 16px 0;\"\u003e\n  The integrated RFI filter (B20 option) makes the drive compliant with\n  EN 61800-3 Class A1, so cabinet installation does not require an external\n  line filter in most industrial environments. For machine builders exporting\n  into residential or light-commercial environments where EN 55011 Class B\n  applies, the B20 filter still helps, but a short motor cable (under 5 m)\n  and proper grounding of the motor housing are mandatory to keep emissions\n  inside the limit. Earth the drive chassis to the cabinet PE bus with a\n  short, large-gauge strap — not through the mounting bolts alone.\n\u003c\/p\u003e\n\n\u003c!-- ============ 4. Installation \u0026 Commissioning Tips ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  4. Installation \u0026amp; Commissioning Tips\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003e\n  Plan for at least 100 mm of clearance above and below the drive for vertical\n  cooling airflow. The VLT 2800 frame A2 supports side-by-side mounting with\n  no derating, which is useful when packing several drives into a single\n  cabinet. The book-style (flat-mount) option requires the optional mounting\n  bracket. Ambient temperature must stay between −10 °C and\n  +40 °C without derating; up to +50 °C requires either a derate or\n  forced cabinet ventilation.\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003e\n  On first power-up, run the Quick Menu for motor data (parameter 1-20\/1-22\n  \/1-23) and confirm ramp times in 3-4x (accel) and 3-8x (decel). For a\n  1.5 kW pump or fan, a 5–10 second accel\/decel ramp is a safe starting\n  point. If the load is a brake-controlled hoist, drop decel to 1–2 s\n  and verify the brake resistor ohm value against the drive’s minimum\n  permitted R\u003csub\u003emin\u003c\/sub\u003e (printed on the label) — never go below it.\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003e\n  Most field issues with the VLT 2815 trace to three root causes: (1) the\n  analog input configured for voltage while the PLC outputs current, giving\n  full-scale-at-zero behaviour, (2) the STO \/ safe-stop terminal left open,\n  preventing the start command, and (3) the brake resistor undersized for\n  the duty cycle, which trips warning “W19”. Use the LCP 2 to\n  read the active alarm number, then cross-check the code in the\n  \u003ca href=\"\/ar\/pages\/plc-error-code-lookup\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePLC Error Code Database\u003c\/a\u003e\n  or feed the photo of the rating plate into the\n  \u003ca href=\"\/ar\/pages\/ai-tool\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAI Diagnostic Tool\u003c\/a\u003e\n  for a faster cross-reference.\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  For firmware programming, MCT-10 (Danfoss PC Tool) connects via the drive’s\n  RS-485 port using the traditional 9-pin to terminal adapter. Parameter sets\n  can be backed up to the LCP 2 and cloned across a fleet, which is convenient\n  for OEM builds with multiple identical lines. Always lock parameter group 0\n  (parameter 0-60 = [1] Locked) once commissioning is complete to prevent\n  field operators from changing critical setpoints.\n\u003c\/p\u003e\n\n\u003c!-- ============ 5. Procurement, Warranty \u0026 Lead Time ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  5. Procurement, Warranty \u0026amp; Lead Time\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003e\n  The 195N1041 is part of the VLT 2800 long-running catalog, with broad\n  aftermarket availability through the channel. KOEED typically keeps both\n  new-surplus and tested pull units on the shelf for fast MRO. Each drive is\n  inspected for visible damage, power-on smoke-test (no-load), and parameter\n  reset to factory defaults before shipment.\n\u003c\/p\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #eeeeee; font-family:Arial, Helvetica, sans-serif; font-size:14px; margin:0 0 24px 0;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eCondition\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eNew-surplus and tested pull units available\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003ePre-shipment Test\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003ePower-on smoke test, parameter reset, terminal inspection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eWarranty\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e12 months limited warranty (terms per KOEED policy)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eLead Time\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eIn stock: ships within 2–5 business days; backorders quoted per email\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eShipping\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eWorldwide shipping via DHL \/ FedEx \/ UPS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eCompatible Resistors\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eDanfoss brake resistor sized per VLT 2800 design guide\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSiblings in same family\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        \u003ca href=\"\/ar\/products\/danfoss-vlt-2805\" style=\"color:#0056B3; text-decoration:underline;\"\u003eVLT 2805 (0.55 kW)\u003c\/a\u003e ·\n        \u003ca href=\"\/ar\/products\/danfoss-vlt-2811\" style=\"color:#0056B3; text-decoration:underline;\"\u003eVLT 2811 (1.1 kW)\u003c\/a\u003e ·\n        \u003ca href=\"\/ar\/products\/danfoss-vlt-2822\" style=\"color:#0056B3; text-decoration:underline;\"\u003eVLT 2822 (2.2 kW)\u003c\/a\u003e ·\n        \u003ca href=\"\/ar\/products\/danfoss-vlt-2830\" style=\"color:#0056B3; text-decoration:underline;\"\u003eVLT 2830 (3.0 kW)\u003c\/a\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eRFQ Channel\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        Email \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Danfoss%20VLT2815PT4B20STR0DBF10A00\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e or use the\n        \u003ca href=\"\/ar\/pages\/request-for-quote\" style=\"color:#0056B3; text-decoration:underline;\"\u003eCreate a Quote\u003c\/a\u003e form\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  Need a full multi-brand bill of materials — Danfoss drives, an\n  \u003ca href=\"\/ar\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley ControlLogix\u003c\/a\u003e\n  PLC, a \u003ca href=\"\/ar\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e HMI, an\n  \u003ca href=\"\/ar\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e servo, a\n  \u003ca href=\"\/ar\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e vision system —\n  send the full list to \u003cstrong\u003eMoritta@KOEED.COM\u003c\/strong\u003e and KOEED will reply\n  with availability and price within 24 hours on business days. KOEED is an\n  independent multi-brand distributor and sourcing partner for\n  \u003ca href=\"\/ar\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e,\n  \u003ca href=\"\/ar\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e,\n  \u003ca href=\"\/ar\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e,\n  \u003ca href=\"\/ar\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e,\n  \u003ca href=\"\/ar\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e,\n  \u003ca href=\"\/ar\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e,\n  \u003ca href=\"\/ar\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e,\n  \u003ca href=\"\/ar\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic\u003c\/a\u003e\n  and \u003ca href=\"\/ar\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e\n  industrial automation spare parts, and is not affiliated with the original\n  manufacturers.\n\u003c\/p\u003e\n\n\u003c!-- ============ Main Inquiry CTA ============ --\u003e\n\u003cdiv style=\"background-color:#16c8c8; padding:24px 32px; margin:32px 0; text-align:center; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003ch3 style=\"margin:0 0 12px 0; color:#ffffff; font-size:20px; line-height:28px;\"\u003e\n    Need this VLT 2815 or a full drive bill of materials?\n  \u003c\/h3\u003e\n  \u003cp style=\"margin:0 0 16px 0; color:#ffffff; font-size:15px; line-height:22px;\"\u003e\n    Send your part list to \u003cstrong\u003eMoritta@KOEED.COM\u003c\/strong\u003e and get availability + price within 24 hours.\n  \u003c\/p\u003e\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Danfoss%20VLT2815PT4B20STR0DBF10A00\" style=\"display:inline-block; background-color:#ffffff; color:#0056B3; padding:12px 24px; text-decoration:none; font-weight:bold; border-radius:4px; font-size:15px;\"\u003e\n    Request a Quote →\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- ============ Secondary CTA ============ --\u003e\n\u003cdiv style=\"border:1px solid #0056B3; padding:16px 24px; margin:16px 0; text-align:left; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 8px 0; color:#111111; font-size:15px; line-height:22px;\"\u003e\n    Looking for more in the same VLT 2800 family or alternative VFD brands?\n  \u003c\/p\u003e\n  \u003ca href=\"\/ar\/collections\/danfoss\" style=\"display:inline-block; color:#0056B3; padding:6px 18px; text-decoration:none; font-weight:bold; border:1px solid #0056B3; border-radius:4px; font-size:14px; margin-right:8px;\"\u003e\n    Browse Danfoss Drives →\n  \u003c\/a\u003e\n  \u003ca href=\"\/ar\/collections\/factory-automation\" style=\"display:inline-block; color:#0056B3; padding:6px 18px; text-decoration:none; font-weight:bold; border:1px solid #0056B3; border-radius:4px; font-size:14px;\"\u003e\n    Browse VFDs \u0026amp; Inverters →\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- ============ Tertiary CTA \/ Tools ============ --\u003e\n\u003cdiv style=\"border:1px solid #eeeeee; background-color:#f4fcfc; padding:16px 24px; margin:16px 0; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 4px 0; color:#111111; font-size:15px; font-weight:bold;\"\u003e\n    \u0026gt; Need help sizing the brake resistor or commissioning the VLT 2815?\n  \u003c\/p\u003e\n  \u003cp style=\"margin:0 0 8px 0; color:#333333; font-size:14px;\"\u003e\n    Try the KOEED free online PLC and drive toolset, or contact Moritta@KOEED.COM directly.\n  \u003c\/p\u003e\n  \u003ca href=\"\/ar\/pages\/modbus-crc-calculator\" style=\"color:#0056B3; text-decoration:underline; font-weight:bold; font-size:14px; margin-right:16px;\"\u003e\n    Open Modbus CRC Calculator\n  \u003c\/a\u003e\n  \u003ca href=\"\/ar\/pages\/ai-tool\" style=\"color:#0056B3; text-decoration:underline; font-weight:bold; font-size:14px;\"\u003e\n    Open AI Diagnostic Tool\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- ============ Footer Mini-Links ============ --\u003e\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#555555; font-size:13px; line-height:20px; margin:24px 0 0 0;\"\u003e\n  Related brands: \u003ca href=\"\/ar\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e ·\n  \u003ca href=\"\/ar\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e ·\n  \u003ca href=\"\/ar\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e ·\n  \u003ca href=\"\/ar\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e ·\n  \u003ca href=\"\/ar\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e ·\n  \u003ca href=\"\/ar\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e ·\n  \u003ca href=\"\/ar\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e ·\n  \u003ca href=\"\/ar\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic\u003c\/a\u003e ·\n  \u003ca href=\"\/ar\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e ·\n  \u003ca href=\"\/ar\/pages\/about-china-sourcing-company\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAbout China Sourcing\u003c\/a\u003e ·\n  \u003ca href=\"\/ar\/pages\/contact-us\" style=\"color:#0056B3; text-decoration:underline;\"\u003eContact Us\u003c\/a\u003e\n\u003c\/p\u003e\n","brand":"DANFOSS","offers":[{"title":"Default Title","offer_id":46634376659129,"sku":"157759268472","price":395.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0268\/8476\/7929\/files\/1_2c6b4928-f0bc-4870-89ad-dc891e144183.webp?v=1774230732","url":"https:\/\/koeed.com\/ar\/products\/one-danfoss-195n1041-vlt2815pt4b20str0dbf10a00-inverter-qw","provider":"KOEED","version":"1.0","type":"link"}