{"product_id":"omron-e5ewl-r1tc-temperature-controller-one-free-shipping-e5ewlr1tc","title":"Omron E5EWL-R1TC Temperature Controller  One Free Shipping E5EWLR1TC","description":"\u003cdiv class=\"product-description-container\" style=\"font-family: 'Segoe UI', Arial, sans-serif; line-height: 1.6; color: #333;\"\u003e\n\n    \u003cp\u003eThe \u003cstrong\u003eOmron E5EWL-R1TC\u003c\/strong\u003e is a professional-grade \u003cstrong\u003edigital temperature controller\u003c\/strong\u003e designed for easy operation and precise thermal management. Featuring a bright, high-contrast display, this \u003cstrong\u003eE5EWL-R1TC PID controller\u003c\/strong\u003e is ideal for standard industrial heating applications. Whether you are looking for an \u003cstrong\u003eE5EWL-R1TC replacement\u003c\/strong\u003e for a packaging machine or an \u003cstrong\u003eequivalent to basic 1\/8 DIN controllers\u003c\/strong\u003e, this genuine Omron unit provides the reliability required for continuous 24\/7 operation.\u003c\/p\u003e\n\n    \u003chr style=\"border: 0; height: 1px; background: #eee; margin: 20px 0;\"\u003e\n\n    \u003ch3 style=\"color: #0053a0; border-left: 4px solid #0053a0; padding-left: 12px; margin-top: 25px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto;\"\u003e\n        \u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 15px; border: 1px solid #e1e1e1;\"\u003e\n            \u003cthead\u003e\n                \u003ctr style=\"background-color: #f5f9ff;\"\u003e\n                    \u003cth style=\"padding: 12px; border: 1px solid #e1e1e1; text-align: left;\"\u003eParameter\u003c\/th\u003e\n                    \u003cth style=\"padding: 12px; border: 1px solid #e1e1e1; text-align: left;\"\u003eDetails\u003c\/th\u003e\n                \u003c\/tr\u003e\n            \u003c\/thead\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1;\"\u003eE5EWL-R1TC (E5EWLR1TC)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #fafafa;\"\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1; font-weight: bold;\"\u003eDimensions\u003c\/td\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1;\"\u003e48 x 96 mm (1\/8 DIN Size)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1; font-weight: bold;\"\u003eControl Output\u003c\/td\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1;\"\u003eRelay Output (SPST-NO, 250 VAC, 3A)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #fafafa;\"\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1; font-weight: bold;\"\u003eInput Type\u003c\/td\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1;\"\u003eThermocouple (K, J, T, R, or S type)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1; font-weight: bold;\"\u003ePower Supply\u003c\/td\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1;\"\u003e100 to 240 VAC, 50\/60 Hz\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #fafafa;\"\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1; font-weight: bold;\"\u003eAlarm Output\u003c\/td\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1;\"\u003e1 Auxiliary Relay Output\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1; font-weight: bold;\"\u003eControl Method\u003c\/td\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1;\"\u003eON\/OFF or 2-PID Control (with Auto-tuning)\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\n    \u003ch3 style=\"color: #0053a0; border-left: 4px solid #0053a0; padding-left: 12px; margin-top: 30px;\"\u003eReliable Temperature Regulation\u003c\/h3\u003e\n    \u003cp\u003eThe \u003cstrong\u003eE5EWL series\u003c\/strong\u003e is part of Omron's essential line of controllers, optimized for high-speed sampling (250ms) and simple setup. This specific \u003cstrong\u003eE5EWL-R1TC model\u003c\/strong\u003e features a large, easy-to-read character height of 16.2mm, allowing operators to monitor the status from a distance. Its rugged housing and industrial-grade internals make it a dependable \u003cstrong\u003eOmron repair part\u003c\/strong\u003e for global manufacturing environments requiring cost-effective yet precise temperature regulation.\u003c\/p\u003e\n\n    \u003ch3 style=\"color: #0053a0; border-left: 4px solid #0053a0; padding-left: 12px; margin-top: 30px;\"\u003eE5EWL-R1TC Troubleshooting FAQ\u003c\/h3\u003e\n    \u003cul style=\"padding-left: 20px;\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eDisplaying \"s.err\"?\u003c\/strong\u003e This indicates an input sensor error. Verify that your thermocouple is connected to the correct terminals and that the \u003cstrong\u003eE5EWL-R1TC\u003c\/strong\u003e input type setting (CN-t) matches the physical sensor type (e.g., K-type).\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eOutput not switching?\u003c\/strong\u003e Check the \"OUT\" indicator on the front panel. If the indicator is ON but the heater isn't heating, check the \u003cstrong\u003eE5EWL-R1TC relay contact\u003c\/strong\u003e wiring and the external contactor.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eUnstable PV reading?\u003c\/strong\u003e Ensure that the thermocouple wire is not running parallel to high-voltage power lines, which can cause electromagnetic interference. Refer to standard \u003cstrong\u003eOmron wiring diagrams\u003c\/strong\u003e for proper shielding techniques.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"OMRON","offers":[{"title":"Default Title","offer_id":45468151087289,"sku":"364608395007","price":81.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0268\/8476\/7929\/files\/s-l500_28f9201c-030a-44ad-a2ea-0d43122e5da3.jpg?v=1761270281","url":"https:\/\/koeed.com\/bn\/products\/omron-e5ewl-r1tc-temperature-controller-one-free-shipping-e5ewlr1tc","provider":"KOEED","version":"1.0","type":"link"}