{"product_id":"new-one-eaton-apr48-es-1800w-rectifier-module","title":"Eaton APR48-ES 1800W Rectifier Module","description":"\u003ch1 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:28px; line-height:36px; margin:0 0 8px 0;\"\u003e\n  Eaton APR48-ES 1800W Rectifier Module — -48V DC Telecom-Grade Power Conversion\n\u003c\/h1\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#0056B3; font-size:14px; line-height:22px;\n          letter-spacing:1px; text-transform:uppercase; margin:0 0 24px 0;\"\u003e\n  Eaton (US) · APR48-ES Series · 1800W Hot-Pluggable Rectifier · 1PC\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:0 0 16px 0;\"\u003e\n  The \u003cstrong\u003eEaton APR48-ES\u003c\/strong\u003e is a 1800W hot-pluggable rectifier module designed for -48V DC telecom power\n  plants (also available in +24V variants for legacy sites). Built by Eaton’s\n  \u003ca href=\"\/cs\/collections\/eaton\" style=\"color:#0056B3; text-decoration:underline;\"\u003eEaton\u003c\/a\u003e power-quality\n  division (successor to Marconi, Lineage Power, and GE Critical Power), the APR48-ES slots into a 1U\n  subrack with a 295mm mounting depth and delivers clean, regulated -48V DC from a universal\n  90–275VAC input. It is the workhorse module behind thousands of -48V plants powering\n  \u003ca href=\"\/cs\/collections\/factory-automation\" style=\"color:#0056B3; text-decoration:underline;\"\u003efactory automation\u003c\/a\u003e,\n  telecom base stations, and enterprise DC bus rooms.\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  For sourcing teams maintaining multi-vendor sites, KOEED keeps APR48-ES modules alongside matching controllers,\n  subracks, and DC distribution panels, and can quote a full \u003ca href=\"\/cs\/pages\/request-for-quote\" style=\"color:#0056B3; text-decoration:underline;\"\u003eBOM\u003c\/a\u003e\n  that bundles the Eaton rectifier with adjacent components from\n  \u003ca href=\"\/cs\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e,\n  \u003ca href=\"\/cs\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e,\n  \u003ca href=\"\/cs\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e,\n  \u003ca href=\"\/cs\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e,\n  \u003ca href=\"\/cs\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e,\n  \u003ca href=\"\/cs\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e,\n  \u003ca href=\"\/cs\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e,\n  \u003ca href=\"\/cs\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic\u003c\/a\u003e, and\n  \u003ca href=\"\/cs\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e.\n\u003c\/p\u003e\n\n\u003c!-- ============ H2 #1: Key Technical Specifications \/ Overview ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Key Technical Specifications \u0026amp; Overview\n\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #eeeeee;\n              font-family:Arial, Helvetica, sans-serif; font-size:14px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee;\n                 color:#111111; font-weight:bold;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        Eaton (formerly Marconi \/ Lineage Power \/ GE Critical Power)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee;\n                 color:#111111; font-weight:bold;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        APR48-ES (48V DC telecom rectifier family)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee;\n                 color:#111111; font-weight:bold;\"\u003ePart Number\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        APR48-ES (1800W variant)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee;\n                 color:#111111; font-weight:bold;\"\u003eModule Type\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        Hot-pluggable rectifier module for -48V DC power plant\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee;\n                 color:#111111; font-weight:bold;\"\u003eOutput Power\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        1800 W continuous (~37.5 A at -48 VDC)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee;\n                 color:#111111; font-weight:bold;\"\u003eAC Input\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        90–275 VAC universal, single-phase, 45–66 Hz\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee;\n                 color:#111111; font-weight:bold;\"\u003eDC Output\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        -48 VDC nominal (also available in +24 V variants for legacy sites)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee;\n                 color:#111111; font-weight:bold;\"\u003eEfficiency\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        \u0026gt; 92% peak, typical telecom-grade curve\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee;\n                 color:#111111; font-weight:bold;\"\u003eCooling\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        Front-to-back forced airflow, integrated variable-speed fan\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee;\n                 color:#111111; font-weight:bold;\"\u003eForm Factor\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        1U height, 295 mm mounting depth, blind-mate rear connectors\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee;\n                 color:#111111; font-weight:bold;\"\u003eController Interface\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        CAN bus \/ RS-485 to plant controller (Eaton SC200 \/ equivalent)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee;\n                 color:#111111; font-weight:bold;\"\u003eHot-Swap\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        Yes — live insertion \/ removal while plant is energized\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee;\n                 color:#111111; font-weight:bold;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        -20 °C to +55 °C (de-rating above 45 °C)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee;\n                 color:#111111; font-weight:bold;\"\u003eCondition\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        New — factory sealed, individually boxed\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee;\n                 color:#111111; font-weight:bold;\"\u003eStock Status\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        In stock — quote within 24 hours at\n        \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Eaton%20APR48-ES%201800W%20Rectifier\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#555555; font-size:14px; line-height:22px; margin:16px 0 0 0;\"\u003e\n  Notes: The APR48-ES shares its 1U \/ 295mm mechanical envelope with the earlier APR48-3G and\n  APR24-ES variants, which is why it is often subbed into legacy Marconi and Lineage Power\n  power shelves. Confirm shelf backplane keying (48V vs 24V) before replacing a module in place.\n\u003c\/p\u003e\n\n\u003c!-- ============ H2 #2: Application Scenarios \/ Where It Fits ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Application Scenarios — Where the APR48-ES Fits\n\u003c\/h2\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTelecom base stations \u0026amp; mobile switching centers.\u003c\/strong\u003e 4G \/ 5G macro cells, BSC \/ RNC sites, and microwave backhaul nodes that need a compact, hot-swappable -48V plant.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnterprise \u0026amp; data center DC bus.\u003c\/strong\u003e Distributed -48V DC distribution to network switches, optical transport, and edge compute racks in hybrid AC\/DC rooms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial process control \u0026amp; PLC backplane power.\u003c\/strong\u003e Stable -48V supply for\n    \u003ca href=\"\/cs\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e,\n    \u003ca href=\"\/cs\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e,\n    \u003ca href=\"\/cs\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e, and\n    \u003ca href=\"\/cs\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e PLC cabinets that require negative-rail DC.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobotics \u0026amp; CNC machine cells.\u003c\/strong\u003e -48V aux supply for\n    \u003ca href=\"\/cs\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e and\n    \u003ca href=\"\/cs\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e servo amplifiers where the controller cabinet is factory-DC, not AC.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVision inspection \u0026amp; sensor stations.\u003c\/strong\u003e Low-noise DC feed for\n    \u003ca href=\"\/cs\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e vision systems and\n    \u003ca href=\"\/cs\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e photoelectric networks sharing a common -48V bus.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRailway signaling \u0026amp; SCADA RTUs.\u003c\/strong\u003e Trackside -48V plants where the rectifier must run from wide-range AC, tolerate temperature swing, and survive live swap.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePanasonic \u0026amp; HMI-heavy workcells.\u003c\/strong\u003e Auxiliary DC rail for\n    \u003ca href=\"\/cs\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic\u003c\/a\u003e FP-series PLCs and operator HMI stacks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:16px 0 0 0;\"\u003e\n  Compared with general-purpose AC-to-DC bricks, the APR48-ES adds plant-grade supervision: current\n  sharing across paralleled modules, float \/ equalize charge control via the system controller, and\n  graceful fan-failure de-rating. That is what makes it the right drop-in for telecom, rail, and\n  industrial -48V rooms — not the cheapest brick, but the one with the right management\n  protocol stack.\n\u003c\/p\u003e\n\n\u003c!-- ============ H2 #3: Integration \u0026 Wiring Notes ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Integration \u0026amp; Wiring Notes\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003e\n  The APR48-ES is a blind-mate module: AC input, -48V return \/ live, and signal backplane all\n  land on the rear connector of the host shelf. Field wiring therefore happens at the subrack,\n  not the module itself. A few integration points that consistently come up on integration\n  calls:\n\u003c\/p\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShelf compatibility.\u003c\/strong\u003e Designed for the APR48-ES subrack family. Mechanical and keying-compatible with legacy APR48-3G shelves, but firmware handshake may differ — check controller firmware notes before mixing generations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAC feed.\u003c\/strong\u003e One dedicated breaker per module, sized for the worst-case 275 VAC input current. Do not daisy-chain the AC feed across multiple rectifiers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDC return.\u003c\/strong\u003e Use a single-point ground for -48V return per TIA \/ ETSI grounding practice to avoid ground-loop noise reaching downstream\n    \u003ca href=\"\/cs\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e or\n    \u003ca href=\"\/cs\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e analog front ends.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBattery bus.\u003c\/strong\u003e When the APR48-ES feeds a battery-backed -48V string, size the DC cabling for the full battery discharge current, not just the rectifier-rated load.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eController link.\u003c\/strong\u003e The CAN \/ RS-485 bus to the plant controller (SC200 or successor) carries load share, alarm, and on\/off commands. Terminate the bus at both ends; never star the controller mid-run.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLoad sharing.\u003c\/strong\u003e Parallel APR48-ES modules auto-balance via the backplane, but only if each module sees the same firmware revision. A mixed-firmware shelf can current-oscillate under step load.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVentilation clearance.\u003c\/strong\u003e Keep the front intake and rear exhaust clear by at least 100 mm — this is the most common cause of premature fan failure we see in the field.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:16px 0 0 0;\"\u003e\n  Cross-vendor note: the APR48-ES uses the same -48V rail as\n  \u003ca href=\"\/cs\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e SITOP and\n  \u003ca href=\"\/cs\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e Galaxy\n  plants at the bus level, but the controller protocol is proprietary. If you are migrating\n  from a third-party plant, the rectifier will parallel cleanly, but the SCADA \/ alarm mapping\n  will not — budget time for controller-side point re-mapping.\n\u003c\/p\u003e\n\n\u003c!-- ============ H2 #4: Installation \u0026 Commissioning Tips ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Installation \u0026amp; Commissioning Tips\n\u003c\/h2\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePre-power checks.\u003c\/strong\u003e Verify shelf AC feed is off and locked-out \/ tagged-out (LOTO) before inserting a new module. Confirm the slot keying matches the variant (48V vs 24V) before sliding the unit in.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeating.\u003c\/strong\u003e Push the module in until the front faceplate is flush with the shelf — the blind-mate connector is on a floating plate, so partial seating can give intermittent output under vibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFirst power-up.\u003c\/strong\u003e With the AC breaker closed, the module should ramp to -54.5 V float within 5–10 seconds. The green “DC OK” LED and the absence of an audible fan alarm are the two go\/no-go signals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eController handshake.\u003c\/strong\u003e On a fresh shelf, run the controller’s rectifier auto-discovery. The APR48-ES will report serial, firmware, output voltage, and current — confirm the controller log shows all expected modules.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLoad step test.\u003c\/strong\u003e Apply a 50% step load and watch the controller current-share graph. Modules should re-balance within 1–2 seconds; a slow re-balance usually means a backplane pin issue, not a module fault.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal soak.\u003c\/strong\u003e After 4 hours at full load, scan the front grille with a thermal camera. Hot spots above 60 °C typically point to blocked intake, not a defective module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFirmware alignment.\u003c\/strong\u003e If you are topping up a shelf that already has APR48-ES modules, match the firmware revision. Mixed revisions on the same CAN bus can throw false current-share alarms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpare strategy.\u003c\/strong\u003e For unmanned sites, keep one hot-standby module per shelf in the same firmware batch. The APR48-ES supports N+1 redundancy by design — but only if the standby module is online and pre-shared.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDocument the row.\u003c\/strong\u003e After commissioning, log the slot position, serial, and firmware of every module in the plant register. This is the single biggest time-saver when a module fails two years later and you need a like-for-like replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:16px 0 0 0;\"\u003e\n  If you are integrating the APR48-ES into a larger cell that also runs\n  \u003ca href=\"\/cs\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e,\n  \u003ca href=\"\/cs\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e, or\n  \u003ca href=\"\/cs\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic\u003c\/a\u003e controls on\n  the same cabinet, segregate the -48V return path from any 24V I\/O returns to avoid ground\n  interaction on fault events.\n\u003c\/p\u003e\n\n\u003c!-- ============ H2 #5: Procurement, Warranty \u0026 Lead Time ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Procurement, Warranty \u0026amp; Lead Time\n\u003c\/h2\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuotation.\u003c\/strong\u003e KOEED quotes the APR48-ES on a per-piece or full-shelf basis. Send the quantity, target firmware revision, and any controller \/ shelf cross-reference to\n    \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Eaton%20APR48-ES%201800W%20Rectifier\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e for a written quote.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLead time.\u003c\/strong\u003e In-stock units ship within 1–3 business days from our Shenzhen \/ Hong Kong warehouses. Large or firmware-locked builds typically ship within 2–4 weeks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMulti-brand BOM.\u003c\/strong\u003e If the APR48-ES is being installed alongside\n    \u003ca href=\"\/cs\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e,\n    \u003ca href=\"\/cs\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e, or\n    \u003ca href=\"\/cs\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e components,\n    bundle them in one\n    \u003ca href=\"\/cs\/pages\/request-for-quote\" style=\"color:#0056B3; text-decoration:underline;\"\u003eBOM request\u003c\/a\u003e\n    to consolidate shipping and documentation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty.\u003c\/strong\u003e New units ship with a 12-month limited warranty covering manufacturing defects under normal operating conditions. Warranty excludes damage from improper AC wiring, liquid ingress, or operation above the de-rated temperature envelope.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAuthenticity.\u003c\/strong\u003e Every module is sourced through vetted channels and visually inspected (label integrity, connector pins, firmware label match) before dispatch. Photo evidence is available on request.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWorldwide shipping.\u003c\/strong\u003e DHL \/ FedEx \/ UPS door-to-door, with export documentation prepared for North America, EU, MENA, LATAM, and Southeast Asia. Hazmat does not apply to -48V rectifier modules under IATA \/ IMDG, which keeps cross-border logistics simple.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eObsolete \u0026amp; legacy.\u003c\/strong\u003e Need a cross-reference for an APR48-3G, APR24-ES, or older Marconi \/ Lineage Power rectifier? Send the existing part number and we will propose a verified migration path.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:16px 0 0 0;\"\u003e\n  Pricing is by quote — send the part list, target quantity, and delivery window to\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Eaton%20APR48-ES%201800W%20Rectifier\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e and you\n  will get a written response within 24 hours on business days.\n\u003c\/p\u003e\n\n\u003c!-- ============ Primary CTA ============ --\u003e\n\u003cdiv style=\"background-color:#16c8c8; padding:24px 32px; margin:32px 0; text-align:center;\n            font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003ch3 style=\"margin:0 0 12px 0; color:#ffffff; font-size:20px; line-height:28px;\"\u003e\n    Need this rectifier or a full -48V plant BOM?\n  \u003c\/h3\u003e\n  \u003cp style=\"margin:0 0 16px 0; color:#ffffff; font-size:15px; line-height:22px;\"\u003e\n    Send your part list to \u003cstrong\u003eMoritta@KOEED.COM\u003c\/strong\u003e and get availability + price within 24 hours.\n  \u003c\/p\u003e\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Eaton%20APR48-ES%201800W%20Rectifier\" style=\"display:inline-block; background-color:#ffffff; color:#0056B3; padding:12px 24px;\n            text-decoration:none; font-weight:bold; border-radius:4px; font-size:15px;\"\u003e\n    Request a Quote →\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- ============ Secondary CTA ============ --\u003e\n\u003cdiv style=\"border:1px solid #0056B3; padding:16px 24px; margin:16px 0; text-align:left;\n            font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 8px 0; color:#111111; font-size:15px; line-height:22px;\"\u003e\n    Looking for the rest of the Eaton APR48 family or adjacent DC power components?\n  \u003c\/p\u003e\n  \u003ca href=\"\/cs\/collections\/eaton\" style=\"display:inline-block; color:#0056B3; padding:6px 18px;\n            text-decoration:none; font-weight:bold; border:1px solid #0056B3;\n            border-radius:4px; font-size:14px;\"\u003e\n    Browse Eaton Power Modules →\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- ============ Tool CTA ============ --\u003e\n\u003cdiv style=\"border:1px solid #eeeeee; background-color:#f4fcfc; padding:16px 24px; margin:16px 0;\n            font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 4px 0; color:#111111; font-size:15px; font-weight:bold;\"\u003e\n    \u0026gt; Sizing a -48V plant or checking controller load-share math?\n  \u003c\/p\u003e\n  \u003cp style=\"margin:0 0 8px 0; color:#333333; font-size:14px;\"\u003e\n    Use the KOEED free online PLC \/ DC engineering toolset.\n  \u003c\/p\u003e\n  \u003ca href=\"\/cs\/pages\/plc-analog-calculator\" style=\"color:#0056B3; text-decoration:underline; font-weight:bold; font-size:14px;\"\u003e\n    Open PLC Analog Calculator\n  \u003c\/a\u003e\n\u003c\/div\u003e\n","brand":"EATON","offers":[{"title":"Default Title","offer_id":44406183297209,"sku":"314186466089","price":506.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0268\/8476\/7929\/files\/s-l1600_82109b04-6c93-4608-88cd-630962f9bc53.jpg?v=1723240981","url":"https:\/\/koeed.com\/cs\/products\/new-one-eaton-apr48-es-1800w-rectifier-module","provider":"KOEED","version":"1.0","type":"link"}