{"product_id":"new-inductotherm-1473176w-ip-147-3176-w-thyristor-module","title":"Induction Thermistor Module 1473176W IP#147-3176-W","description":"\u003ch1 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:28px; line-height:36px; margin:0 0 8px 0;\"\u003e\n  Inductotherm 1473176W (IP 147-3176-W) Water-Cooled Thyristor Module — 1PC\n\u003c\/h1\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#0056B3; font-size:14px; line-height:22px; letter-spacing:1px; text-transform:uppercase; margin:0 0 24px 0;\"\u003e\n  Inductotherm · IP 147 Series · Water-Cooled Phase-Controlled SCR · Specialty \/ OEM Sourcing\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:0 0 16px 0;\"\u003e\n  The \u003cstrong\u003eInductotherm IP 147-3176-W\u003c\/strong\u003e (often written \u003cstrong\u003e1473176W\u003c\/strong\u003e) is a water-cooled, phase-controlled thyristor (SCR) module drawn from Inductotherm's IP 147 series of high-power, phase-leg semiconductor assemblies. It is built for the harsh electrical and thermal environment inside Inductotherm induction melting and heating power supplies — VIP, Dual-Trak and Mainline families — and ships as a single ready-to-bolt module. Inductotherm is a U.S. leader in induction melting, holding, forging and heat-treat equipment, and the IP 147 platform is the workhorse power-conversion building block for those furnaces.\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:0 0 16px 0;\"\u003e\n  KOEED is best known as your \u003ca href=\"\/da\/collections\" style=\"color:#0056B3; text-decoration:underline;\"\u003emulti-brand industrial automation supplier\u003c\/a\u003e for the nine core PLC \/ drive \/ HMI brands — Allen-Bradley, Siemens, Mitsubishi, Omron, Fanuc, Schneider, Yaskawa, Panasonic and KEYENCE. We list the \u003cstrong\u003e1473176W\u003c\/strong\u003e here as an \u003cem\u003eadjacent specialty line\u003c\/em\u003e: when the same foundry or forge plant needs a power-electronics module to keep an Inductotherm power supply running, we treat it the same way we treat a hard-to-find PLC CPU — \u003ca href=\"\/da\/pages\/about-china-sourcing-company\" style=\"color:#0056B3; text-decoration:underline;\"\u003esourced through our China sourcing network\u003c\/a\u003e, datasheet-checked, and quoted within 24 hours at \u003ca href=\"mailto:Moritta@KOEED.COM\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e.\n\u003c\/p\u003e\n\n\u003c!-- ============ 1. Key Technical Specifications \/ Overview ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Key Technical Specifications \/ Overview\n\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #eeeeee; font-family:Arial, Helvetica, sans-serif; font-size:14px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eInductotherm (U.S. induction heating leader)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eManufacturer Part Number\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e1473176W \/ IP 147-3176-W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSeries \/ Platform\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eInductotherm IP 147 series — water-cooled phase-controlled SCR module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eDevice Class\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003ePhase-controlled thyristor \/ SCR power module (single \/ dual \/ three-phase arm configurations available on the IP 147 platform)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eApprox. Current Class\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e~1500 A class (per-arm rating, IP 147 series envelope)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eApprox. Voltage Class\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e~1200 V class V\u003csub\u003eRRM\u003c\/sub\u003e \/ V\u003csub\u003eDRM\u003c\/sub\u003e envelope (verify against Inductotherm nameplate)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eCooling Method\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eWater-cooled (suffix \"W\" in the P\/N indicates water-cooled base)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eHousing \/ Mounting\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eStack-style industrial module, bus-bar power terminals, gate \u0026amp; auxiliary signal terminals; cabinet-mount via clamp or stud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eCompatible Inductotherm Power Supplies\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eVIP, Dual-Trak and Mainline induction melting \/ heating converters (always cross-check model \u0026amp; schematic before order)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eTriggering\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003ePhase-angle \/ firing-angle control via Inductotherm control board; gate pulse per Inductotherm IP 147 datasheet\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eQuantity Per Order\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e1PC (single module; pair \/ stack pricing available for full-bridge builds)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eTypical Industries\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eFoundry, forge, heat-treat, vacuum induction melting, semi-solid metal forming, process heating\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eStock Status\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eSourced on RFQ — confirm availability and lead time at \u003ca href=\"mailto:Moritta@KOEED.COM\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#555555; font-size:13px; line-height:20px; margin:12px 0 0 0;\"\u003e\n  Specifications above describe the published envelope of the Inductotherm IP 147 series. Always reconcile the exact 147-3176-W rating with the Inductotherm nameplate, schematic and revision of your power supply before substituting.\n\u003c\/p\u003e\n\n\u003c!-- ============ 2. Application Scenarios \/ Where It Fits ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Application Scenarios \/ Where It Fits\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:0 0 16px 0;\"\u003e\n  The \u003cstrong\u003e1473176W\u003c\/strong\u003e is a building block inside Inductotherm's medium-to-large induction power-conversion systems. KOEED typically sees enquiries from the following plants and lines, all of which pair the SCR module with the standard PLC \/ drive stack we keep in stock under our nine core brands — including \u003ca href=\"\/da\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley ControlLogix\u003c\/a\u003e, \u003ca href=\"\/da\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens SIMATIC S7-1500\u003c\/a\u003e, \u003ca href=\"\/da\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi MELSEC iQ-R\u003c\/a\u003e and \u003ca href=\"\/da\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider Modicon M580\u003c\/a\u003e as the cell-level controller.\n\u003c\/p\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFoundry coreless furnaces\u003c\/strong\u003e — VIP \/ Dual-Trak power supplies melting steel, iron, copper and aluminum alloys where the SCR arm is the controlled rectifier stage before the DC bus.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChannel and holding furnaces\u003c\/strong\u003e — duplex \/ holding furnaces in iron and non-ferrous foundries for melt temperature stability between pour cycles.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eForge billet, bar, slab and plate heating\u003c\/strong\u003e — Inductotherm billet heaters and bar-end heaters feeding forging presses; the IP 147 platform delivers the fast firing-angle response needed for slug temperature control.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeat treat — gears, shafts, axles\u003c\/strong\u003e — dual-frequency and single-frequency heat-treat lines used by automotive tier-1 and tier-2 suppliers for case hardening and through-hardening.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVacuum induction melting (VIM)\u003c\/strong\u003e — specialty alloy melting where the IP 147 converter drives the induction coil inside the vacuum chamber.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSemi-solid metal forming (SSM \/ thixoforging)\u003c\/strong\u003e — controlled billet reheating to the semi-solid range before forging.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpare-module replacement on aging Inductotherm cabinets\u003c\/strong\u003e — the IP 147 platform has been in service for two decades, so replacement of a single failed arm is a common, high-impact repair on legacy cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:16px 0 0 0;\"\u003e\n  If the line is PLC-driven elsewhere, you can browse the same-day automation stack that typically sits in front of an Inductotherm cabinet: \u003ca href=\"\/da\/products\/1756-L73\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley 1756-L73\u003c\/a\u003e processors, \u003ca href=\"\/da\/products\/6ES7-315-2EH14\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens 6ES7 315-2EH14\u003c\/a\u003e CPUs, \u003ca href=\"\/da\/products\/MR-J4-100A\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi MR-J4-100A\u003c\/a\u003e servo amplifiers, \u003ca href=\"\/da\/products\/CP1E-N40DR-A\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron CP1E-N40DR-A\u003c\/a\u003e small PLCs, \u003ca href=\"\/da\/products\/A06B-6089-H106\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc A06B-6089-H106\u003c\/a\u003e servo amplifiers, and \u003ca href=\"\/da\/products\/CV-5000\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE CV-5000\u003c\/a\u003e vision for billet-end inspection. Browse the full \u003ca href=\"\/da\/collections\" style=\"color:#0056B3; text-decoration:underline;\"\u003eindustrial automation parts catalog\u003c\/a\u003e for the rest of the line.\n\u003c\/p\u003e\n\n\u003c!-- ============ 3. Integration \u0026 Wiring Notes ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Integration \u0026amp; Wiring Notes\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:0 0 16px 0;\"\u003e\n  The \u003cstrong\u003eIP 147-3176-W\u003c\/strong\u003e is a phase-arm module, not a stand-alone inverter. Treat it as a sub-assembly inside the original Inductotherm cabinet and follow these integration rules when you install or replace it on a live furnace line.\n\u003c\/p\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBus-bar torque \u0026amp; contact surface.\u003c\/strong\u003e Use the Inductoderm-specified torque values on the power terminals. The copper bus-bars must be flat, deburred and lightly lubricated with the contact grease the OEM calls out; any high-resistance joint will show up as localized heating long before the SCR itself fails.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCooling-water circuit integrity.\u003c\/strong\u003e Confirm inlet temperature, flow rate and water conductivity (typically de-ionized) match the Inductotherm IP 147 datasheet before energising. A blocked or un-degassed water circuit is the most common root cause of a failed SCR module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGate-drive and firing-board compatibility.\u003c\/strong\u003e Use only the Inductotherm IP 147 firing board \/ control board revision listed in your power-supply schematic. Mixing an IP 147 arm with a non-OEM firing board will void the OEM gate-drive protection and the snubber network.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSnubber and dv\/dt protection.\u003c\/strong\u003e Do not run an IP 147 module without its RC snubber network. The module is designed to switch inside a tuned snubber, and removing the snubber will dramatically shorten device life.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding and shielding.\u003c\/strong\u003e The cabinet ground loop, water-pipe grounding and signal-cable shielding must follow the Inductotherm drawing. We see noisy gate-drive faults traced back to a single missing shield termination.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCoordination with downstream PLC.\u003c\/strong\u003e Wire the Inductotherm status outputs (over-temperature, water flow, DC-link fault) into a discrete input module on the line PLC — for example an \u003ca href=\"\/da\/products\/1756-IB16IF\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley 1756-IB16IF\u003c\/a\u003e or a \u003ca href=\"\/da\/products\/6ES7-321-1BL00\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens SM 321\u003c\/a\u003e — so a trip on the power supply is logged, not just indicated locally.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhase-rotation and line-sync check.\u003c\/strong\u003e After any replacement, verify phase rotation, line-sync reference and firing-angle zero-cross calibration before re-melting. This is a documented step in every Inductotherm commissioning manual.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:16px 0 0 0;\"\u003e\n  For cell-level wiring help on the PLC side of the cabinet, the \u003ca href=\"\/da\/pages\/modbus-crc-calculator\" style=\"color:#0056B3; text-decoration:underline;\"\u003eModbus CRC Calculator\u003c\/a\u003e and the \u003ca href=\"\/da\/pages\/plc-hex-float-converter\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePLC Hex to Float Converter\u003c\/a\u003e are useful when commissioning the data link between the Inductotherm controller and the line PLC.\n\u003c\/p\u003e\n\n\u003c!-- ============ 4. Installation \u0026 Commissioning Tips ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Installation \u0026amp; Commissioning Tips\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:0 0 16px 0;\"\u003e\n  A water-cooled SCR module in a foundry or forge cabinet has a very different service profile from a control-cabinet PLC, so the installation discipline is closer to a power-electronics swap than a card-edge replacement. The points below reflect what we hear from maintenance teams running Inductotherm VIP, Dual-Trak and Mainline supplies.\n\u003c\/p\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLock-out \/ tag-out the DC bus, not just the AC feed.\u003c\/strong\u003e The DC-link capacitor bank in an IP 147 cabinet will hold charge for several minutes after the AC is opened. Follow the OEM discharge time and verify with a known-good meter before touching the bus.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInspect the cooling-water strainer and O-rings.\u003c\/strong\u003e On a re-install after a water-side leak, replace the O-rings on every water fitting you disturb. A slow seep at a re-used O-ring is the most common cause of a repeat failure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal-cycling test before load.\u003c\/strong\u003e After re-energising, run the cabinet at low firing angle for at least one full thermal cycle and inspect each water joint for weeps and each bus-bar joint with a thermal camera. Do not pour the first heat until the thermal profile is flat.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFirst-load ramp.\u003c\/strong\u003e Bring the furnace up on a low-melt-point, low-value charge (e.g. aluminum sow) for the first heat after a module change. Only move to the production alloy once the firing-angle response and water temperature delta look nominal.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLog baseline parameters.\u003c\/strong\u003e Capture DC-link voltage, firing angle, water-in \/ water-out temperature and DC current at the end of the first full heat, and store them with the work order. Drift on any of these is the earliest indicator of a developing fault.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDocument the IP 147 revision.\u003c\/strong\u003e Inductotherm revises the IP 147 family over time. Stamp the module's revision letter and the cabinet schematic revision on every work order — this is the single biggest time-saver the next time the line trips.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:16px 0 0 0;\"\u003e\n  If you want a second opinion on the line's PLC \/ HMI side while the cabinet is open, the \u003ca href=\"\/da\/pages\/ai-tool\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKOEED AI Diagnostic Tool\u003c\/a\u003e accepts a nameplate photo and will suggest cross-references and known issues for the major PLC brands — useful when the Inductotherm cabinet is controlled by an older \u003ca href=\"\/da\/products\/1747-L542\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley SLC 500\u003c\/a\u003e or \u003ca href=\"\/da\/products\/A1SJCPU\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi A1S\u003c\/a\u003e CPU that you are trying to keep alive.\n\u003c\/p\u003e\n\n\u003c!-- ============ 5. Procurement, Warranty \u0026 Lead Time ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Procurement, Warranty \u0026amp; Lead Time\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:0 0 16px 0;\"\u003e\n  The \u003cstrong\u003eInductotherm 1473176W\u003c\/strong\u003e is a specialty industrial power-electronics part, not a stocked shelf item. KOEED treats procurement the same way we treat any hard-to-find PLC module in our nine core brands — a clean RFQ flow, datasheet reconciliation, and a single email thread from enquiry to delivery.\n\u003c\/p\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRFQ-driven quotation.\u003c\/strong\u003e Pricing is supplied on request. Send the P\/N, the Inductotherm power-supply model, the schematic revision and the quantity to \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Inductotherm%20IP%20147-3176-W%20Thyristor\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e — you will get availability and a quote within 24 hours on business days.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBOM quotation welcome.\u003c\/strong\u003e If you are re-building a full Inductotherm cabinet or a full plant PLC \/ drive list, attach the whole BOM to one email. We quote the lot, not the line.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLead time.\u003c\/strong\u003e Single-piece orders for the 1473176W are typically filled from our China sourcing pipeline in 5–15 business days depending on the cabinet revision and the country of destination. We will confirm an actual lead time on the quote email.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWorldwide shipping.\u003c\/strong\u003e DHL, FedEx, UPS and standard air-freight are available. Shipments are insured and tracked; export documents (commercial invoice, packing list, COO where applicable) are provided.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty.\u003c\/strong\u003e New Inductotherm-sourced modules are covered against manufacturing defect on the terms printed on the quote. Warranty does not cover damage from incorrect installation, missing cooling water, lost snubber networks or use of a non-OEM firing board.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReturns \u0026amp; RMA.\u003c\/strong\u003e Returns follow the published KOEED \u003ca href=\"\/da\/pages\/return-policy\" style=\"color:#0056B3; text-decoration:underline;\"\u003ereturn policy\u003c\/a\u003e. For a specialty power-electronics part we ask that the part be returned in the original Inductotherm packaging where possible.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCross-reference \u0026amp; substitutes.\u003c\/strong\u003e If the 1473176W is end-of-life on your specific cabinet revision, send the schematic — we will propose either an Inductotherm IP 147 family equivalent or a third-party water-cooled SCR module of equivalent V\u003csub\u003eRRM\u003c\/sub\u003e \/ I\u003csub\u003eT(AV)\u003c\/sub\u003e rating, after a technical check.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDon't see it in the catalog?\u003c\/strong\u003e If the part number you actually need is not the 1473176W but a related IP 147 variant or a different Inductotherm spare, follow the rule printed on our home page: \u003cem\u003e\"If you can't find what you need in this website, please contact and send us the instruments list.\"\u003c\/em\u003e Email \u003ca href=\"mailto:Moritta@KOEED.COM\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e or open a \u003ca href=\"\/da\/pages\/request-for-quote\" style=\"color:#0056B3; text-decoration:underline;\"\u003eCreate a Quote\u003c\/a\u003e request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:16px 0 0 0;\"\u003e\n  KOEED is a multi-brand industrial automation distributor focused on Allen-Bradley, Siemens, Mitsubishi, Omron, Fanuc, Schneider, Yaskawa, Panasonic and KEYENCE, with a sourcing extension into specialty industrial power electronics like the Inductotherm IP 147 family. For every quote, the workflow is the same: datasheet → quote within 24 hours → tracked worldwide delivery. If you would like a same-day response, send the P\/N, the cabinet model and the quantity straight to \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Inductotherm%20IP%20147-3176-W%20Thyristor\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e.\n\u003c\/p\u003e\n\n\u003c!-- ============ Inquiry CTA ============ --\u003e\n\u003cdiv style=\"background-color:#16c8c8; padding:24px 32px; margin:32px 0; text-align:center; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003ch3 style=\"margin:0 0 12px 0; color:#ffffff; font-size:20px; line-height:28px;\"\u003eNeed this part or a full Inductotherm cabinet BOM?\u003c\/h3\u003e\n  \u003cp style=\"margin:0 0 16px 0; color:#ffffff; font-size:15px; line-height:22px;\"\u003eSend your part list to \u003cstrong\u003eMoritta@KOEED.COM\u003c\/strong\u003e and get availability \u0026amp; price within 24 hours.\u003c\/p\u003e\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Inductotherm%20IP%20147-3176-W%20Thyristor\" style=\"display:inline-block; background-color:#ffffff; color:#0056B3; padding:12px 24px; text-decoration:none; font-weight:bold; border-radius:4px; font-size:15px;\"\u003eRequest a Quote →\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"border:1px solid #0056B3; padding:16px 24px; margin:16px 0; text-align:left; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 8px 0; color:#111111; font-size:15px; line-height:22px;\"\u003eLooking for the rest of the foundry \/ forge PLC \u0026amp; drive stack?\u003c\/p\u003e\n  \u003ca href=\"\/da\/collections\" style=\"display:inline-block; color:#0056B3; padding:6px 18px; text-decoration:none; font-weight:bold; border:1px solid #0056B3; border-radius:4px; font-size:14px;\"\u003eBrowse all 9 brands →\u003c\/a\u003e\n   \n  \u003ca href=\"\/da\/pages\/about-china-sourcing-company\" style=\"display:inline-block; color:#0056B3; padding:6px 18px; text-decoration:none; font-weight:bold; border:1px solid #0056B3; border-radius:4px; font-size:14px;\"\u003eAbout our China sourcing →\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"border:1px solid #eeeeee; background-color:#f4fcfc; padding:16px 24px; margin:16px 0; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 4px 0; color:#111111; font-size:15px; font-weight:bold;\"\u003e\u0026gt; Need to identify an Inductotherm or PLC nameplate quickly?\u003c\/p\u003e\n  \u003cp style=\"margin:0 0 8px 0; color:#333333; font-size:14px;\"\u003eTry the KOEED free online AI toolset — photo nameplate, get cross-references.\u003c\/p\u003e\n  \u003ca href=\"\/da\/pages\/ai-tool\" style=\"color:#0056B3; text-decoration:underline; font-weight:bold; font-size:14px;\"\u003eOpen the AI Diagnostic Tool\u003c\/a\u003e\n\u003c\/div\u003e\n","brand":"INDUCTION","offers":[{"title":"Default Title","offer_id":44260668702905,"sku":"166363234952","price":570.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0268\/8476\/7929\/files\/s-l1600_a2656f99-2887-4adc-87a8-3e7b5a4e17b5.jpg?v=1723765990","url":"https:\/\/koeed.com\/da\/products\/new-inductotherm-1473176w-ip-147-3176-w-thyristor-module","provider":"KOEED","version":"1.0","type":"link"}