{"product_id":"822ua-1c-c-car-sh-124du-24vdc-30a-goodsky-power-relay-5pcs","title":"822UA-1C-C CAR-SH-124DU 24VDC 30A GoodSky Power Relay 5PCS","description":"\u003ch1 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:28px; line-height:36px; margin:0 0 8px 0;\"\u003e\n  Goodsky 822UA-1C-C — 24VDC 30A Power Relay (5 pcs)\n\u003c\/h1\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#0056B3; font-size:14px; line-height:22px; letter-spacing:1px; text-transform:uppercase; margin:0 0 24px 0;\"\u003e\n  Goodsky · 822 Series · 1 Form C (SPDT) · In stock\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:0 0 16px 0;\"\u003e\n  The \u003cstrong\u003eGoodsky 822UA-1C-C (CAR-SH-124DU)\u003c\/strong\u003e is a heavy-duty T-shape PCB \/ plug-in\n  \u003ca href=\"\/de\/products\/822ua-1c-c-car-sh-124du-24vdc-30a-goodsky-power-relay-5pcs\" style=\"color:#0056B3; text-decoration:underline;\"\u003epower relay\u003c\/a\u003e\n  rated \u003cstrong\u003e30 A at 250 VAC \/ 30 VDC\u003c\/strong\u003e with a 24 VDC coil. Manufactured by\n  \u003ca href=\"\/de\/collections\/goodsky\" style=\"color:#0056B3; text-decoration:underline;\"\u003eGoodsky\u003c\/a\u003e\n  (Taiwan Goodsky Electric Co.) — one of Asia’s most established relay brands — it ships as a\n  5-piece pack for prototyping, panel building and field service. Sourced by KOEED alongside\n  \u003ca href=\"\/de\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e,\n  \u003ca href=\"\/de\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e,\n  \u003ca href=\"\/de\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e,\n  \u003ca href=\"\/de\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e,\n  \u003ca href=\"\/de\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e,\n  \u003ca href=\"\/de\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e,\n  \u003ca href=\"\/de\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e,\n  \u003ca href=\"\/de\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic\u003c\/a\u003e\n  and\n  \u003ca href=\"\/de\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e\n  spares for one-stop BOM quotation.\n\u003c\/p\u003e\n\n\u003c!-- ============ H2 #1 Key Technical Specifications ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Key Technical Specifications\n\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #eeeeee; font-family:Arial, Helvetica, sans-serif; font-size:14px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        Goodsky (Taiwan Goodsky Electric Co.)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSeries \/ Type\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        822 \/ UA T-shape PCB or plug-in power relay\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eFull Part Number\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        822UA-1C-C (order code: CAR-SH-124DU)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eModule Type\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        Electromechanical Power Relay · 1 Form C (SPDT)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eContact Rating\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        30 A @ 250 VAC \/ 30 VDC resistive\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eCoil Voltage\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        24 VDC\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eCoil Power\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        Approx. 0.9 W (360 mA nominal pickup)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eContact Material\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        Silver alloy (suffix “C” in part number)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eDielectric Strength\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        2500 VAC, 1 min (coil to contact)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eInsulation Resistance\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        1000 MΩ min @ 500 VDC\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eMechanical Life\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        10,000,000 operations\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eElectrical Life\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        100,000 operations @ rated load\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        −40 °C to +85 °C\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eMounting Style\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        Through-hole PCB pins or 822-series compatible socket (plug-in)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eCase \/ Cover\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        Sealed dust-cover plastic case\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003ePack Quantity\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        5 pieces per pack\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eStock Status\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        In stock — quote within 24 h at \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Goodsky%20822UA-1C-C\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c!-- ============ H2 #2 Application Scenarios ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Application Scenarios \u0026amp; Where It Fits\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003e\n  The 30 A contact envelope and 24 VDC coil put the\n  \u003ca href=\"\/de\/collections\/power-relays\" style=\"color:#0056B3; text-decoration:underline;\"\u003e822UA-1C-C\u003c\/a\u003e\n  in the sweet spot for mid-current switching in\n  \u003ca href=\"\/de\/collections\/industrial-automation\" style=\"color:#0056B3; text-decoration:underline;\"\u003eindustrial automation\u003c\/a\u003e\n  panels. It is widely used as a logic-to-power interface relay, complementing PLC outputs from\n  Allen-Bradley CompactLogix or Siemens S7-1200 systems, and as a driver relay for motor contactors\n  from Schneider TeSys or Mitsubishi S-N series.\n\u003c\/p\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n    \u003ca href=\"\/de\/collections\/hvac-controls\" style=\"color:#0056B3; text-decoration:underline;\"\u003eHVAC\u003c\/a\u003e\n    rooftop units, AHU fan stages and compressor control boards\n  \u003c\/li\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003eVending machines, coffee makers, commercial refrigeration defrost timers\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n    Commercial washing machines, dryers, dishwashers and laundry control panels\n  \u003c\/li\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n    \u003ca href=\"\/de\/collections\/ups-systems\" style=\"color:#0056B3; text-decoration:underline;\"\u003eUPS\u003c\/a\u003e\n    and inverter\n    \u003ca href=\"\/de\/collections\/power-supplies\" style=\"color:#0056B3; text-decoration:underline;\"\u003eswitch-mode power supplies\u003c\/a\u003e\n    where a 30 A relay is used for bypass \/ transfer switching\n  \u003c\/li\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003eWelding and plasma-cut equipment, machine-tool spindle coolant pumps\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n    \u003ca href=\"\/de\/collections\/charging-stations\" style=\"color:#0056B3; text-decoration:underline;\"\u003eEV charging stations\u003c\/a\u003e\n    and battery management contactor pre-drivers\n  \u003c\/li\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n    \u003ca href=\"\/de\/collections\/factory-automation\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFactory automation\u003c\/a\u003e\n    relay-logic interposing panels alongside Omron MY2N or Yaskawa drive I\/O boards\n  \u003c\/li\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n    Fanuc and Panasonic robotic cell safety \/ E-stop interlock chains\n  \u003c\/li\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n    Vision-guided inspection stations that pair the relay with a KEYENCE CV-5000 trigger output\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c!-- ============ H2 #3 Integration \u0026 Wiring Notes ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Integration \u0026amp; Wiring Notes\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003e\n  Reading the suffix helps: \u003cstrong\u003e“UA”\u003c\/strong\u003e denotes the T-shape 822 case and contact family;\n  \u003cstrong\u003e“1C”\u003c\/strong\u003e means 1 pole, Form C (SPDT) — one common, one normally-open, one\n  normally-closed; the trailing \u003cstrong\u003e“C”\u003c\/strong\u003e indicates a silver-alloy contact.\n  The order code \u003cem\u003eCAR-SH-124DU\u003c\/em\u003e decodes as: CAR = CAR-truck family, SH = sealed dust cover,\n  124 = 24 VDC coil, DU = Form C SPDT.\n\u003c\/p\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n    \u003cstrong\u003eCoil pins:\u003c\/strong\u003e A1 (+) and A2 (−) accept 24 VDC. The coil is not internally suppressed\n    — add a flyback diode (1N4007 reverse-biased) if driven directly by a Panasonic FP-X or\n    Omron CP1H transistor output.\n  \u003c\/li\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n    \u003cstrong\u003eContact pins:\u003c\/strong\u003e COM (common), NO (normally open) and NC (normally closed) on the\n    load side. The silver-alloy contacts handle inrush well; for capacitive loads (SMPS, EV\n    chargers), add an RC snubber or a varistor (MOV) across the contact to suppress arcing.\n  \u003c\/li\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n    \u003cstrong\u003eSocket option:\u003c\/strong\u003e Use a 822-series compatible 5-pin PCB socket or DIN-rail socket\n    so the relay can be swapped without desoldering — convenient for field service on Siemens\n    or Allen-Bradley retrofit panels.\n  \u003c\/li\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n    \u003cstrong\u003eFootprint:\u003c\/strong\u003e Standard 5-pin T-shape pitch (~5 mm). Maintain 10 mm clearance around\n    the relay body to keep the contact temperature inside its rated 85 °C ceiling.\n  \u003c\/li\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n    \u003cstrong\u003eDriving a contactor:\u003c\/strong\u003e Wire the 30 A contact in series with the coil of a\n    Schneider LC1D or Mitsubishi S-N20 contactor when switching motors above 30 A.\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c!-- ============ H2 #4 Installation \u0026 Commissioning Tips ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Installation \u0026amp; Commissioning Tips\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003e\n  Even a robust relay like the Goodsky 822UA-1C-C will fail prematurely if it is wired, mounted or\n  driven outside its envelope. The following tips come from field service on Yaskawa servo cabinets,\n  CNC panels and OEM machine builds.\n\u003c\/p\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n    \u003cstrong\u003ePolarity:\u003c\/strong\u003e Observe A1\/A2 polarity. Reversed polarity on the DC coil can cause\n    weak pull-in and contact welding under heavy inrush.\n  \u003c\/li\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n    \u003cstrong\u003ePCB soldering:\u003c\/strong\u003e Hand-solder at 340 °C max with a 3 s dwell to avoid plastic-case\n    deformation. Use a socket when the relay will be replaced more than once in the panel’s life.\n  \u003c\/li\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n    \u003cstrong\u003eSnubber sizing:\u003c\/strong\u003e For 230 VAC motor loads, a 0.1 µF + 100 Ω RC snubber\n    across the contact extends electrical life 3–5×.\n  \u003c\/li\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n    \u003cstrong\u003eSurge on the coil:\u003c\/strong\u003e A reversed-biode (1N4007) or a 36 V TVS across A1\/A2 is\n    strongly recommended when the coil is driven by a KEYENCE or Omron transistor output.\n  \u003c\/li\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n    \u003cstrong\u003eMounting orientation:\u003c\/strong\u003e Prefer vertical (contact terminals down). If the relay\n    is mounted horizontally, derate the contact current by ~15 % because of convection loss.\n  \u003c\/li\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n    \u003cstrong\u003ePre-commissioning check:\u003c\/strong\u003e With the panel unpowered, measure coil resistance\n    (should be ~640 Ω for 24 VDC). With power on, verify pickup voltage (~18 V) and dropout\n    voltage (~2.4 V) before connecting the load.\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c!-- ============ H2 #5 Procurement, Warranty \u0026 Lead Time ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Procurement, Warranty \u0026amp; Lead Time\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003e\n  KOEED is an independent multi-brand industrial-automation distributor — not a Goodsky\n  subsidiary — so we can place the 822UA-1C-C alongside Allen-Bradley PLCs, Siemens HMIs and\n  Mitsubishi inverters on a single BOM, with one invoice and one shipment.\n\u003c\/p\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n\u003cstrong\u003eMOQ:\u003c\/strong\u003e 1 pack (5 pcs) for samples and field service; volume pricing tiers at 20 \/ 100 \/ 500 pcs.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n\u003cstrong\u003eLead time:\u003c\/strong\u003e Pack-of-5 typically in stock; OEM quantities quoted within 24 hours via \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Goodsky%20822UA-1C-C\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month replacement warranty against manufacturing defect, backed by our \u003ca href=\"\/de\/pages\/about-china-sourcing-company\" style=\"color:#0056B3; text-decoration:underline;\"\u003eChina Sourcing Company\u003c\/a\u003e QC flow.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n\u003cstrong\u003eWorldwide shipping:\u003c\/strong\u003e DHL \/ FedEx \/ UPS, with full export documentation. See the \u003ca href=\"\/de\/pages\/shipping-policy\" style=\"color:#0056B3; text-decoration:underline;\"\u003eshipping policy\u003c\/a\u003e for cut-off times.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n\u003cstrong\u003eAuthentication:\u003c\/strong\u003e Each lot traceable to Goodsky production batch. Tested for coil resistance, contact bounce and dielectric strength before despatch.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 6px 0;\"\u003e\n\u003cstrong\u003eHard-to-find sourcing:\u003c\/strong\u003e Need an EOL or obsolete Goodsky part alongside a Fanuc A06B servo? \u003ca href=\"\/de\/pages\/real-time-sales-list\" style=\"color:#0056B3; text-decoration:underline;\"\u003eRecent shipments\u003c\/a\u003e show the kind of BOMs we already cover.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:16px 0 0 0;\"\u003e\n  Need a matching 822-series socket, a DIN-rail base, or the full BOM for a\n  \u003ca href=\"\/de\/collections\/factory-automation\" style=\"color:#0056B3; text-decoration:underline;\"\u003econtrol panel\u003c\/a\u003e\n  rebuild? Send the part list to\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Goodsky%20822UA-1C-C\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e\n  and we will reply with availability and price within 24 hours on business days.\n  For other relay and power-component needs, see our\n  \u003ca href=\"\/de\/collections\/power-relays\" style=\"color:#0056B3; text-decoration:underline;\"\u003efull power-relay lineup\u003c\/a\u003e\n  or the\n  \u003ca href=\"\/de\/pages\/faq\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKOEED FAQ\u003c\/a\u003e.\n\u003c\/p\u003e\n\n\u003c!-- ============ Main CTA ============ --\u003e\n\u003cdiv style=\"background-color:#16c8c8; padding:24px 32px; margin:32px 0; text-align:center; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003ch3 style=\"margin:0 0 12px 0; color:#ffffff; font-size:20px; line-height:28px;\"\u003e\n    Need this part or a full BOM?\n  \u003c\/h3\u003e\n  \u003cp style=\"margin:0 0 16px 0; color:#ffffff; font-size:15px; line-height:22px;\"\u003e\n    Send your part list to \u003cstrong\u003eMoritta@KOEED.COM\u003c\/strong\u003e and get availability + price within 24 hours.\n  \u003c\/p\u003e\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Goodsky%20822UA-1C-C\" style=\"display:inline-block; background-color:#ffffff; color:#0056B3; padding:12px 24px; text-decoration:none; font-weight:bold; border-radius:4px; font-size:15px;\"\u003e\n    Request a Quote →\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- ============ Secondary CTA ============ --\u003e\n\u003cdiv style=\"border:1px solid #0056B3; padding:16px 24px; margin:16px 0; text-align:left; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 8px 0; color:#111111; font-size:15px; line-height:22px;\"\u003e\n    Looking for more Goodsky parts or a complete panel?\n  \u003c\/p\u003e\n  \u003ca href=\"\/de\/pages\/request-for-quote\" style=\"display:inline-block; color:#0056B3; padding:6px 18px; text-decoration:none; font-weight:bold; border:1px solid #0056B3; border-radius:4px; font-size:14px;\"\u003e\n    Create a Quote →\n  \u003c\/a\u003e\n   \n  \u003ca href=\"\/de\/pages\/contact-us\" style=\"display:inline-block; color:#0056B3; padding:6px 18px; text-decoration:none; font-weight:bold; border:1px solid #0056B3; border-radius:4px; font-size:14px;\"\u003e\n    Contact Sales →\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- ============ Tertiary CTA ============ --\u003e\n\u003cdiv style=\"border:1px solid #eeeeee; background-color:#f4fcfc; padding:16px 24px; margin:16px 0; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 4px 0; color:#111111; font-size:15px; font-weight:bold;\"\u003e\n    \u0026gt; Engineers: planning a relay swap or need a control-panel rebuild?\n  \u003c\/p\u003e\n  \u003cp style=\"margin:0 0 8px 0; color:#333333; font-size:14px;\"\u003e\n    Use the KOEED free online PLC toolset for wiring and signal checks.\n  \u003c\/p\u003e\n  \u003ca href=\"\/de\/pages\/plc-hex-float-converter\" style=\"color:#0056B3; text-decoration:underline; font-weight:bold; font-size:14px;\"\u003e\n    Open PLC Hex to Float Converter\n  \u003c\/a\u003e\n   · \n  \u003ca href=\"\/de\/pages\/plc-error-code-lookup\" style=\"color:#0056B3; text-decoration:underline; font-weight:bold; font-size:14px;\"\u003e\n    PLC Error Code Database\n  \u003c\/a\u003e\n\u003c\/div\u003e\n","brand":"GOODSKY","offers":[{"title":"Default Title","offer_id":46635992613049,"sku":"287208581419","price":27.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0268\/8476\/7929\/files\/1_8c579dd2-b877-4055-b158-d4815a76ac94.webp?v=1774233152","url":"https:\/\/koeed.com\/de\/products\/822ua-1c-c-car-sh-124du-24vdc-30a-goodsky-power-relay-5pcs","provider":"KOEED","version":"1.0","type":"link"}