{"product_id":"new-1pcs-keyence-sj-l005f-sjl005f-compact-fan-static-eliminator","title":"KEYENCE SJ-L005F Compact Fan Static Eliminator","description":"\u003ch1 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:28px; line-height:36px; margin:0 0 8px 0;\"\u003e\n  Keyence SJ-L005F Compact Fan Static Eliminator — Wide-Area Ioniser with Alarm Output\n\u003c\/h1\u003e\n\u003cp style=\"color:#0056B3; font-family:Arial, Helvetica, sans-serif; font-size:13px; letter-spacing:0.6px; text-transform:uppercase; margin:0 0 24px 0;\"\u003e\n  Keyence SJ-L Series · AC-Pulse Ioniser · Static Discharge for Assembly Lines\n\u003c\/p\u003e\n\n\u003cp style=\"color:#333333; font-family:Arial, Helvetica, sans-serif; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  The \u003cstrong\u003eKeyence SJ-L005F\u003c\/strong\u003e is a compact fan-type static eliminator (ioniser) from Keyence's \u003cstrong\u003eSJ-L series\u003c\/strong\u003e. The unit combines a built-in cross-flow fan with an AC-pulse corona discharge electrode to neutralise static charge on parts, films, and trays passing under the airflow. The \"F\" suffix denotes the alarm-output variant: an NPN \/ PNP alarm signal is asserted when ion emission drops below a healthy threshold, which the line PLC reads as a predictive-maintenance input — typically a Mitsubishi MELSEC, Keyence KV, or Allen-Bradley MicroLogix.\n\u003c\/p\u003e\n\n\u003cp style=\"color:#333333; font-family:Arial, Helvetica, sans-serif; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  At \u003cstrong\u003e\u003ca href=\"https:\/\/koeed.com\" style=\"color:#0056B3; text-decoration:none;\"\u003ekoeed.com\u003c\/a\u003e\u003c\/strong\u003e we list the SJ-L005F as an \u003cstrong\u003eESD-control consumable\u003c\/strong\u003e for electronics assembly, plastic-parts handling, film \/ sheet converting, and pharmaceutical packaging. The emitter pin and the air filter are the wear parts; the body itself is usually replaced only when the alarm output flags a failure, or when a keyence-SJ legacy line is being refreshed.\n\u003c\/p\u003e\n\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:28px 0 12px 0;\"\u003eKey Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #eeeeee; font-family:Arial, Helvetica, sans-serif; font-size:14px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; width:32%; color:#111111; font-weight:bold;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eKeyence Corporation (Japan)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eModel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eSJ-L005F (also written SJL005F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eKeyence SJ-L series static eliminators\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eFunction\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eWide-area static elimination (ioniser) with built-in fan and AC-pulse corona discharge\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eIonisation Method\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eAC-pulse corona discharge (tungsten \/ alloy emitter pins)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eAir-Flow Source\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eBuilt-in cross-flow fan (no external compressed-air supply)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eEffective Range (typical)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003e100 – 600 mm from the discharge face (model-class typical; verify by datasheet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eDecay Time (typical)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003e±1000 V → ±100 V in ≤ 1.5 s (at 200 mm, model-class typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eAlarm Output\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eNPN \/ PNP transistor output (variant dependent) — high when ion emission drops below threshold\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSupply Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003e24 VDC (typical SJ-L class)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003ePower Consumption\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eModel-class typical ~5 W (verify on the side label)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eConnector\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eM8 \/ M12 connector lead (variant dependent) for power and alarm output\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eMounting\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eBracket \/ stand-off mount over the conveyor or workstation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003e0 °C to +40 °C (verify by datasheet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eCompliance\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eCE \/ UL listed — see Keyence datasheet\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eCondition\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eBrand-new, factory-sealed Keyence SJ-L unit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eUnit\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003e1 piece (1 pcs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:28px 0 12px 0;\"\u003eDatasheet Highlights\u003c\/h2\u003e\n\u003cul style=\"color:#333333; font-family:Arial, Helvetica, sans-serif; font-size:15px; line-height:24px; padding-left:20px;\"\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003eBuilt-in cross-flow fan means the unit can be installed with no compressed-air supply — ideal for cell-side or conveyor-side installation where an air line is not available.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003eAC-pulse corona discharge gives balanced positive \/ negative ion emission, which is the right method for high-decay-rate, low-residual-voltage applications on plastic parts and films.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\"F\" alarm-output variant asserts a digital signal when the emitter pin wears past a healthy threshold — that signal can be tied into a PLC input for predictive maintenance, which is the right way to manage a fleet of ionisers on a long line.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003eEmission-balance calibration at the factory means out-of-the-box performance matches the published decay-time spec — important when the cell is in a regulated ESD-control program (ANSI\/ESD S20.20, IEC 61340-5-1).\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003eRemovable emitter-pin cartridge and air-filter element can be replaced as a PM, extending the life of the body well past the typical 2-3 year maintenance cycle.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e24 VDC supply is shared with the rest of the cell — the SJ-L005F drops onto the same Phoenix Contact or Meanwell 24 VDC bus that feeds the PLC and the I\/O.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:28px 0 12px 0;\"\u003eTypical Applications\u003c\/h2\u003e\n\u003cul style=\"color:#333333; font-family:Arial, Helvetica, sans-serif; font-size:15px; line-height:24px; padding-left:20px;\"\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003eElectronics assembly:\u003c\/strong\u003e PCB and component-handling cells where static-discharge damage is the leading cause of latent field failures.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003ePlastic-parts feeding:\u003c\/strong\u003e pick-and-place cells handling moulded parts, where static causes parts to stick to the gripper or fly off the conveyor.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003eFilm \u0026amp; sheet converting:\u003c\/strong\u003e unwinding and slitting lines where static attracts dust and causes the web to wander.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003ePharmaceutical packaging:\u003c\/strong\u003e blister-pack and bottle-filling lines where the regulatory ESD-control program requires a documented decay-time target.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003eCleanroom cells:\u003c\/strong\u003e semiconductor and display fabs where the SJ-L005F provides balanced ionisation without a particle-generating compressed-air supply.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003eVision-system stations:\u003c\/strong\u003e Keyence CV-X \/ IV3 inspection cells where a static charge on the part can deflect a laser-line profile and cause false rejects.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:28px 0 12px 0;\"\u003eRelated Modules \u0026amp; Cross-Reference\u003c\/h2\u003e\n\u003cp style=\"color:#333333; font-family:Arial, Helvetica, sans-serif; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003e\n  Static-control is a cell-level concern, so the SJ-L005F is normally purchased alongside the PLC that reads the alarm output and the vision system that depends on the static-free environment. KOEED can ship the SJ-L005F with that wider cell kit:\n\u003c\/p\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #eeeeee; font-family:Arial, Helvetica, sans-serif; font-size:14px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; width:32%; color:#111111; font-weight:bold;\"\u003eAllen-Bradley \/ Rockwell\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eMicroLogix 1400 \/ CompactLogix 5380 reading the alarm output, 1734 IB8 digital input module, 1606-XL 24 VDC supply\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSiemens\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eLOGO! 8 \/ S7-1200 reading the alarm, SIMATIC SM1221 digital input module, SITOP 24 VDC supply\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eMitsubishi\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eMELSEC iQ-F FX5U reading the alarm, FX5-16EX digital input, S8VK 24 VDC supply\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eOmron\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eCP2E \/ NX102 reading the alarm, NX-ID digital input, S8VK 24 VDC supply\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSchneider Electric\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eModicon M221 \/ M241 reading the alarm, TM3DI8 digital input, ABL8 24 VDC supply\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eFANUC\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eFANUC robot cell controller receiving the alarm over PROFINET \/ EtherNet\/IP, FANUC iRVision cells paired with the SJ-L005F\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eYaskawa\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eYaskawa MPiec \/ MP3300iec reading the alarm, GA500 drive on the cell conveyor, Sigma-7 on the pick-and-place axis\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003ePanasonic \/ Keyence\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003ePanasonic FP7 reading the alarm + GT32 HMI; Keyence CV-X \/ IV3 \/ LJ-X vision systems that benefit from the static-free environment\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"color:#333333; font-family:Arial, Helvetica, sans-serif; font-size:14px; line-height:22px; margin:12px 0 0 0;\"\u003e\n  Browse the \u003ca href=\"https:\/\/koeed.com\/collections\/static-control\" style=\"color:#0056B3; text-decoration:none;\"\u003eKOEED static-control \u0026amp; ESD\u003c\/a\u003e and \u003ca href=\"https:\/\/koeed.com\/collections\/keyence\" style=\"color:#0056B3; text-decoration:none;\"\u003eKeyence\u003c\/a\u003e collections to bundle a full cell-ESD kit.\n\u003c\/p\u003e\n\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:28px 0 12px 0;\"\u003eWarranty \u0026amp; Authenticity\u003c\/h2\u003e\n\u003cp style=\"color:#333333; font-family:Arial, Helvetica, sans-serif; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003e\n  Each SJ-L005F is supplied as a brand-new, factory-sealed Keyence SJ-L unit with lot code and date code recorded for full traceability. KOEED sources from authorised Japanese and EU distribution; counterfeits and pulled units are rejected at incoming inspection. A 12-month limited warranty covers manufacturing defects; KOEED handles return shipping and replacement from EU\/US stock at no charge.\n\u003c\/p\u003e\n\n\u003cdiv style=\"background-color:#16c8c8; border-radius:6px; padding:24px 28px; margin:32px 0; font-family:Arial, Helvetica, sans-serif;\"\u003e\n  \u003ch3 style=\"color:#ffffff; font-size:20px; line-height:28px; margin:0 0 8px 0;\"\u003eNeed this ioniser or a full ESD-control kit?\u003c\/h3\u003e\n  \u003cp style=\"color:#ffffff; font-size:15px; line-height:22px; margin:0 0 16px 0; opacity:0.95;\"\u003e\n    Send us your existing SJ-L model, the cell PLC family, and the operating distance to the part. We'll match the SJ-L005F (or a closer SJ-L variant) and bundle emitter cartridges, 24 VDC supply, and the alarm-input module in the same shipment.\n  \u003c\/p\u003e\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Keyence%20SJ-L005F%20Static%20Eliminator\" style=\"display:inline-block; background-color:#ffffff; color:#0056B3; padding:12px 24px; text-decoration:none; font-weight:bold; border-radius:4px; font-size:15px;\"\u003eRequest a Quote →\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"border:1px solid #0056B3; border-radius:6px; padding:20px 24px; margin:24px 0; font-family:Arial, Helvetica, sans-serif;\"\u003e\n  \u003ch3 style=\"color:#0056B3; font-size:18px; line-height:26px; margin:0 0 8px 0;\"\u003eLooking for more ionisers, ESD-control, or Keyence spares?\u003c\/h3\u003e\n  \u003cp style=\"color:#333333; font-size:14px; line-height:22px; margin:0 0 12px 0;\"\u003e\n    Browse the KOEED B2B automation portfolio for related static-control and assembly-cell components.\n  \u003c\/p\u003e\n  \u003ca href=\"https:\/\/koeed.com\/collections\/static-control\" style=\"display:inline-block; background-color:#0056B3; color:#ffffff; padding:10px 20px; text-decoration:none; font-weight:bold; border-radius:4px; font-size:14px;\"\u003eBrowse Static Control \u0026amp; ESD →\u003c\/a\u003e\n    \n  \u003ca href=\"https:\/\/koeed.com\/collections\/keyence\" style=\"display:inline-block; background-color:#ffffff; color:#0056B3; padding:10px 20px; text-decoration:none; font-weight:bold; border-radius:4px; font-size:14px; border:1px solid #0056B3;\"\u003eBrowse Keyence →\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"color:#999999; font-family:Arial, Helvetica, sans-serif; font-size:12px; line-height:18px; margin:24px 0 0 0;\"\u003e\n  Cross-reference: SJ-L005F · SJL005F · Keyence SJ-L series · fan static eliminator with alarm output · AC-pulse ioniser · B2B industrial automation spares. KOEED Automation — independent distributor of industrial automation spare parts, including Allen-Bradley, Siemens, Mitsubishi, Omron, Schneider Electric, FANUC, Yaskawa, Panasonic, and Keyence.\n\u003c\/p\u003e\n","brand":"KEYENCE","offers":[{"title":"Default Title","offer_id":44567912186041,"sku":"355443527920","price":504.58,"currency_code":"USD","in_stock":true}],"url":"https:\/\/koeed.com\/el\/products\/new-1pcs-keyence-sj-l005f-sjl005f-compact-fan-static-eliminator","provider":"KOEED","version":"1.0","type":"link"}