{"product_id":"1pcs-abb-inverter-acs310-03u-34a1-4","title":"1PCS ABB inverter ACS310-03U-34A1-4","description":"\u003c!-- ============ H1 + Subtitle + Intro ============ --\u003e\n\u003ch1 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:28px; line-height:36px; margin:0 0 8px 0;\"\u003e\n  ABB ACS310-03U-34A1-4 Inverter — 3-Phase 380-480V AC Drive, 34A \/ 15 kW\n\u003c\/h1\u003e\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#0056B3; font-size:14px; line-height:22px; letter-spacing:1px; text-transform:uppercase; margin:0 0 24px 0;\"\u003e\n  ABB · ACS310 · VFD \/ AC Drive · In stock for MRO\n\u003c\/p\u003e\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:0 0 16px 0;\"\u003e\n  The \u003cstrong\u003eABB ACS310-03U-34A1-4\u003c\/strong\u003e is a 3-phase 380-480 V general-purpose AC drive (VFD)\n  from the ABB ACS310 pump-and-fan family, rated 34 A continuous output (about 15 kW \/ 20 HP at\n  400 V) in an IP21 \/ NEMA 1 wall-mount enclosure. It is widely used in water-treatment, HVAC,\n  irrigation and industrial-fan retrofits where built-in PID, sensorless vector control and a\n  Modbus RTU fieldbus matter more than high-end programming features. KOEED keeps the\n  \u003ca href=\"\/es\/products\/abb-acs310-03u-34a1-4\" style=\"color:#0056B3; text-decoration:underline;\"\u003eACS310-03U-34A1-4\u003c\/a\u003e\n  in active stock for fast MRO turn-around, and is the same one-stop multi-brand source used for\n  \u003ca href=\"\/es\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e\n  PowerFlex 525 \/ 70 drives,\n  \u003ca href=\"\/es\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e\n  Sinamics V20 \/ G120,\n  \u003ca href=\"\/es\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e\n  Altivar 320 \/ 630 and\n  \u003ca href=\"\/es\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e\n  V1000 \/ A1000 platforms.\n\u003c\/p\u003e\n\n\u003c!-- ============ H2 #1: Key Technical Specifications \/ Overview ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Key Technical Specifications \u0026amp; Overview\n\u003c\/h2\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #eeeeee; font-family:Arial, Helvetica, sans-serif; font-size:14px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eABB (now ABB Motion \/ Drives)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eACS310 — dedicated pump \/ fan drive\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003ePart Number\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eACS310-03U-34A1-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eModule Type\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eGeneral-purpose AC drive \/ VFD (3-phase input, 3-phase output)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eInput Voltage\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e3-phase 380-480 V AC (suffix 03U)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eNominal Output Current\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e34 A continuous (code 34A1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eTypical Motor Power\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e~15 kW \/ 20 HP at 400 V (heavy-duty); up to 18.5 kW \/ 25 HP (light-duty \/ fan)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eInput Frequency\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e50 \/ 60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eEnclosure (suffix 4)\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eIP21 \/ NEMA 1 wall-mount, indoor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eControl Modes\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eV\/f, sensorless vector, built-in PID, pump \u0026amp; fan macros\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eAnalog I\/O\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e2 analog inputs (4-20 mA \/ 0-10 V selectable), 1 analog output\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eDigital I\/O\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e5 digital inputs, 2 relay outputs, 1 digital output\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eFieldbus\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eModbus RTU (RS-485) standard; fieldbus adapters optional\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eOperator Panel\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eIntegral basic panel; optional Assistant panel with start-up wizard\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eCooling\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eInternal fan, top- or side-mount depending on frame size\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eLifecycle\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eLegacy \/ mature — functionally replaced by\n        \u003ca href=\"\/es\/products\/abb-acs580-01-03a3-4\" style=\"color:#0056B3; text-decoration:underline;\"\u003eACS580-01\u003c\/a\u003e,\n        \u003ca href=\"\/es\/products\/abb-ach580-01-03a3-4\" style=\"color:#0056B3; text-decoration:underline;\"\u003eACH580-01\u003c\/a\u003e (HVAC) and\n        \u003ca href=\"\/es\/products\/abb-acq580-01-03a3-4\" style=\"color:#0056B3; text-decoration:underline;\"\u003eACQ580-01\u003c\/a\u003e (water)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eTypical Application\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eWater-supply pumps, booster stations, sewage treatment, HVAC supply \/ return fans, blowers, irrigation pumps\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eStock Status\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eIn stock — quote within 24 hours at\n        \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20ABB%20ACS310-03U-34A1-4\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:16px 0 0 0;\"\u003e\n  The type-code breakdown is worth memorising on the floor: \u003cstrong\u003eACS310\u003c\/strong\u003e = the pump \/\n  fan drive family; \u003cstrong\u003e03U\u003c\/strong\u003e = 3-phase 380-480 V input; \u003cstrong\u003e34A1\u003c\/strong\u003e = 34 A\n  nominal current; \u003cstrong\u003e4\u003c\/strong\u003e = IP21 \/ NEMA 1 enclosure. So if you ever see an\n  ACS310-03U-25A1-4 or ACS310-03U-46A1-4 in the same cabinet, the family and frame are identical\n  and you can wire them up the same way — a useful detail when a spare drive has to come out\n  of a different cubicle.\n\u003c\/p\u003e\n\n\u003c!-- ============ H2 #2: Application Scenarios \/ Where It Fits ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Application Scenarios \u0026amp; Where It Fits\n\u003c\/h2\u003e\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  The ACS310 was designed specifically for variable-torque loads (pumps, fans, blowers) and\n  constant-torque loads that don't need a high-performance servo loop. Typical deployments\n  include:\n\u003c\/p\u003e\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater and wastewater\u003c\/strong\u003e — raw-water intake pumps, transfer pumps in\n    \u003ca href=\"\/es\/collections\/factory-automation\" style=\"color:#0056B3; text-decoration:underline;\"\u003efactory automation\u003c\/a\u003e\n    booster stations, dosing pumps, and sewage-treatment aerators.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHVAC\u003c\/strong\u003e — chilled-water pumps, condenser-water pumps, supply \/ return\n    fans, cooling-tower fans in commercial and light-industrial HVAC plants.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIrrigation\u003c\/strong\u003e — centre-pivot and drip-irrigation pumps where 4-20 mA\n    pressure feedback modulates speed.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProcess fans and blowers\u003c\/strong\u003e — combustion-air blowers, drying-line fans,\n    bag-house exhaust fans in\n    \u003ca href=\"\/es\/collections\/process-control\" style=\"color:#0056B3; text-decoration:underline;\"\u003eprocess control\u003c\/a\u003e\n    cells.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConstant-torque retrofit\u003c\/strong\u003e — replacing across-the-line started\n    conveyors or mixers where soft-start and adjustable speed are both wanted.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  MRO teams that run mixed-brand cabinets are the typical buyer. The same plant might have\n  \u003ca href=\"\/es\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e\n  ControlLogix supervising the line, a\n  \u003ca href=\"\/es\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e\n  S7-1200 next to a Schneider Magelis HMI, and a few ACS310 drives on the pump skid. A\n  \u003ca href=\"\/es\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e\n  FX \/ iQ-R PLC, an\n  \u003ca href=\"\/es\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e\n  CP1 \/ CJ2, and a Yaskawa MP controller can all sit on the same RS-485 Modbus trunk — so\n  the ACS310 doesn't lock you into any particular PLC brand.\n\u003c\/p\u003e\n\n\u003c!-- ============ H2 #3: Integration \u0026 Wiring Notes ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Integration \u0026amp; Wiring Notes\n\u003c\/h2\u003e\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  \u003cstrong\u003ePower terminals.\u003c\/strong\u003e 3-phase L1 \/ L2 \/ L3 in, U \/ V \/ W out to the motor. Earth \/\n  PE must be landed on the dedicated PE terminal before power-up, and the chassis must be bonded\n  to the cabinet protective earth. Output side: do not add a contactor or a sine filter between\n  the drive and the motor unless your cable run exceeds the manufacturer limit — extra\n  capacitance on the output will trip over-current on the first ramp.\n\u003c\/p\u003e\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  \u003cstrong\u003eControl terminals.\u003c\/strong\u003e The default ACS310 macro exposes AI1 (4-20 mA or 0-10 V,\n  jumper-selectable) as the speed reference, AI2 as the PID feedback, DI1 as start \/ stop, DI2\n  as run-reverse (or constant-torque direction), and RO1 \/ RO2 as fault and run relays. The\n  Modbus RTU port is on terminals 29-30 (RS-485 A \/ B) and uses the standard 06 \/ 03 \/ 10 \/ 04\n  function codes. A typical poll cycle from a\n  \u003ca href=\"\/es\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e\n  S7-1200 or a\n  \u003ca href=\"\/es\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e\n  FX5 is a few hundred milliseconds for 6-8 drive parameters — well within what a SCADA\n  refresh needs. For deeper Modbus register mapping, the\n  \u003ca href=\"\/es\/pages\/modbus-crc-calculator\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKOEED Modbus CRC Calculator\u003c\/a\u003e\n  helps you double-check the CRC byte order for the field.\n\u003c\/p\u003e\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  \u003cstrong\u003eProgramming.\u003c\/strong\u003e ABB's Drive Composer entry tool (or the older DriveStudio) talks\n  to the drive over the mini-USB on the Assistant panel, or over Modbus. Parameter sets for\n  typical pump and fan applications are pre-loaded as macros, so most start-ups just pick a macro,\n  enter motor nameplate data, run the ID-run, and you're done. For projects that also pull in\n  \u003ca href=\"\/es\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e\n  CP1H PLCs, a\n  \u003ca href=\"\/es\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e\n  CNC interface, a\n  \u003ca href=\"\/es\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic\u003c\/a\u003e\n  FP-X PLC, or a\n  \u003ca href=\"\/es\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e\n  Sigma-7 servo, the Modbus trunk can be shared — just keep each drive on its own node ID\n  and terminate the bus with 120 Ω at both ends. For PID setpoint scaling, the\n  \u003ca href=\"\/es\/pages\/plc-hex-float-converter\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKOEED PLC Hex to Float Converter\u003c\/a\u003e\n  is handy when you want to read floating-point feedback values from the drive.\n\u003c\/p\u003e\n\n\u003c!-- ============ H2 #4: Installation \u0026 Commissioning Tips ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Installation \u0026amp; Commissioning Tips\n\u003c\/h2\u003e\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  \u003cstrong\u003eMounting.\u003c\/strong\u003e Keep at least 100 mm clearance above and below the drive for\n  airflow, and avoid putting other heat-generating devices (transformers, line reactors) directly\n  underneath. The IP21 rating is good for indoor wall-mount in a control room, but it is not\n  drip-proof — in a wet plant, drop it into a NEMA 3R or IP54 cabinet.\n\u003c\/p\u003e\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  \u003cstrong\u003eCable practice.\u003c\/strong\u003e Use shielded symmetrical VFD cable (or 4-core + overall shield)\n  on the motor side, ground the shield at both ends with 360° bonding, and keep motor cable\n  runs short (under ~50 m is the practical limit on the 34 A frame). For longer runs, an output\n  reactor or dU\/dt filter is recommended. The control wiring should be routed in a separate\n  trough from the power wiring to avoid noise on the analog signals.\n\u003c\/p\u003e\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  \u003cstrong\u003eCommissioning flow.\u003c\/strong\u003e Confirm the wiring is right, power up with the motor\n  uncoupled (or with the load locked-out), enter motor nameplate data, run the ID-run, then\n  reconnect the load. For pump applications, set the PID feedback source to AI2, set the PID\n  setpoint source to a digital reference or a 4-20 mA master, and tune the PID with a\n  step-response test on the actual piping. For fan applications, set a skip-frequency band to\n  avoid resonant duct acoustics. Most field issues with the ACS310 come down to mis-sized input\n  protection, missing PE bonds, or a sensorless-vector ID-run that wasn't completed — the\n  \u003ca href=\"\/es\/pages\/ai-tool\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKOEED AI Diagnostic Tool\u003c\/a\u003e\n  can read a fault code off the panel and suggest a fix path in a few seconds.\n\u003c\/p\u003e\n\n\u003c!-- ============ H2 #5: Procurement, Warranty \u0026 Lead Time ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Procurement, Warranty \u0026amp; Lead Time\n\u003c\/h2\u003e\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  Because the ACS310 is now a legacy \/ mature platform, pricing and lead time on the\n  ACS310-03U-34A1-4 are best confirmed by email. KOEED's standard flow is: send the part number\n  (or a full BOM) to\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20ABB%20ACS310-03U-34A1-4\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e,\n  get a quote back within 24 hours on business days, confirm the build, and ship worldwide via\n  DHL \/ FedEx \/ UPS. For project buys, a\n  \u003ca href=\"\/es\/pages\/request-for-quote\" style=\"color:#0056B3; text-decoration:underline;\"\u003emulti-line Create a Quote form\u003c\/a\u003e\n  lets you bundle the ACS310 with the rest of the cabinet (PLCs, HMIs, breakers, contactors)\n  into a single shipment.\n\u003c\/p\u003e\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  \u003cstrong\u003eWarranty.\u003c\/strong\u003e KOEED sources the ACS310-03U-34A1-4 through qualified channels\n  — each unit is inspected, parameter-tested, and visually verified before it leaves the\n  Shenzhen \/ Hong Kong warehouse, and ships with a standard 12-month warranty. We also handle the\n  \u003ca href=\"\/es\/pages\/acs310-to-acs580-migration\" style=\"color:#0056B3; text-decoration:underline;\"\u003eACS310 to ACS580 \/ ACH580 \/ ACQ580 migration\u003c\/a\u003e\n  for new builds, so if you are upgrading a fleet of drives you can phase the old and new stock\n  side by side. Cross-brand spares (a\n  \u003ca href=\"\/es\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e\n  Altivar 320 next to an ACS310, or a\n  \u003ca href=\"\/es\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic\u003c\/a\u003e\n  FP-X PLC in the same panel) can ride on the same BOM.\n\u003c\/p\u003e\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  \u003cstrong\u003eLead time.\u003c\/strong\u003e For in-stock items the typical lead time is 3-5 business days to\n  most major export hubs (EU, US, Middle East, Southeast Asia, South America) via DHL \/ FedEx.\n  For larger BOM orders or pre-owned \/ refurbished units, expect a slightly longer window —\n  the live status is reflected on our\n  \u003ca href=\"\/es\/pages\/real-time-sales-list\" style=\"color:#0056B3; text-decoration:underline;\"\u003eReal-Time Sales Records\u003c\/a\u003e\n  page. If a direct cross is not available, we will propose an equivalent\n  \u003ca href=\"\/es\/products\/abb-acs580-01-03a3-4\" style=\"color:#0056B3; text-decoration:underline;\"\u003eABB ACS580\u003c\/a\u003e,\n  \u003ca href=\"\/es\/products\/abb-ach580-01-03a3-4\" style=\"color:#0056B3; text-decoration:underline;\"\u003eACH580\u003c\/a\u003e\n  or\n  \u003ca href=\"\/es\/products\/abb-acq580-01-03a3-4\" style=\"color:#0056B3; text-decoration:underline;\"\u003eACQ580\u003c\/a\u003e,\n  or an equivalent from\n  \u003ca href=\"\/es\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e\n  \/\n  \u003ca href=\"\/es\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e\n  \/\n  \u003ca href=\"\/es\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e\n  — whatever keeps the line running. If the part isn't on the website, send the BOM to\n  Moritta@KOEED.COM and we'll come back with a quote.\n\u003c\/p\u003e\n\n\u003c!-- ============ Primary CTA — BOM 询价 ============ --\u003e\n\u003cdiv style=\"background-color:#16c8c8; padding:24px 32px; margin:32px 0; text-align:center; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003ch3 style=\"margin:0 0 12px 0; color:#ffffff; font-size:20px; line-height:28px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Need this drive or a full panel BOM?\n  \u003c\/h3\u003e\n  \u003cp style=\"margin:0 0 16px 0; color:#ffffff; font-size:15px; line-height:22px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Send your part list to \u003cstrong\u003eMoritta@KOEED.COM\u003c\/strong\u003e and get availability + price within 24 hours.\n  \u003c\/p\u003e\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20ABB%20ACS310-03U-34A1-4\" style=\"display:inline-block; background-color:#ffffff; color:#0056B3; padding:12px 24px; text-decoration:none; font-weight:bold; border-radius:4px; font-size:15px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Request a Quote →\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- ============ Secondary CTA — Browse related ============ --\u003e\n\u003cdiv style=\"border:1px solid #0056B3; padding:16px 24px; margin:16px 0; text-align:left; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 8px 0; color:#111111; font-size:15px; line-height:22px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Looking for drives from a different brand?\n  \u003c\/p\u003e\n  \u003ca href=\"\/es\/collections\/schneider\" style=\"display:inline-block; color:#0056B3; padding:6px 18px; text-decoration:none; font-weight:bold; border:1px solid #0056B3; border-radius:4px; font-size:14px; margin:4px 4px 4px 0; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Browse Schneider Altivar →\n  \u003c\/a\u003e\n  \u003ca href=\"\/es\/collections\/yaskawa\" style=\"display:inline-block; color:#0056B3; padding:6px 18px; text-decoration:none; font-weight:bold; border:1px solid #0056B3; border-radius:4px; font-size:14px; margin:4px 4px 4px 0; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Browse Yaskawa V1000 →\n  \u003c\/a\u003e\n  \u003ca href=\"\/es\/collections\/allen-bradley\" style=\"display:inline-block; color:#0056B3; padding:6px 18px; text-decoration:none; font-weight:bold; border:1px solid #0056B3; border-radius:4px; font-size:14px; margin:4px 4px 4px 0; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Browse Allen-Bradley PowerFlex →\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- ============ Tertiary CTA — Engineer tool ============ --\u003e\n\u003cdiv style=\"border:1px solid #eeeeee; background-color:#f4fcfc; padding:16px 24px; margin:16px 0; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 4px 0; color:#111111; font-size:15px; font-weight:bold; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    \u0026gt; Need to convert hex values or check Modbus CRCs for this drive?\n  \u003c\/p\u003e\n  \u003cp style=\"margin:0 0 8px 0; color:#333333; font-size:14px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Try the KOEED free online PLC toolset.\n  \u003c\/p\u003e\n  \u003ca href=\"\/es\/pages\/plc-hex-float-converter\" style=\"color:#0056B3; text-decoration:underline; font-weight:bold; font-size:14px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Open PLC Hex to Float Converter\n  \u003c\/a\u003e\n   · \n  \u003ca href=\"\/es\/pages\/modbus-crc-calculator\" style=\"color:#0056B3; text-decoration:underline; font-weight:bold; font-size:14px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Open Modbus CRC Calculator\n  \u003c\/a\u003e\n   · \n  \u003ca href=\"\/es\/pages\/ai-tool\" style=\"color:#0056B3; text-decoration:underline; font-weight:bold; font-size:14px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Open AI Diagnostic Tool\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- ============ Footer back-links ============ --\u003e\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#555555; font-size:13px; line-height:20px; margin:32px 0 0 0;\"\u003e\n  More on KOEED: \u003ca href=\"\/es\" style=\"color:#0056B3; text-decoration:underline;\"\u003eHome\u003c\/a\u003e ·\n  \u003ca href=\"\/es\/collections\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAll collection\u003c\/a\u003e ·\n  \u003ca href=\"\/es\/pages\/brands\" style=\"color:#0056B3; text-decoration:underline;\"\u003eBrands\u003c\/a\u003e ·\n  \u003ca href=\"\/es\/pages\/about-us\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAbout KOEED\u003c\/a\u003e ·\n  \u003ca href=\"\/es\/pages\/about-china-sourcing-company\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAbout China Sourcing Company\u003c\/a\u003e ·\n  \u003ca href=\"\/es\/pages\/contact-us\" style=\"color:#0056B3; text-decoration:underline;\"\u003eContact Us\u003c\/a\u003e ·\n  \u003ca href=\"\/es\/pages\/faq\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFAQs\u003c\/a\u003e ·\n  \u003ca href=\"\/es\/blog\" style=\"color:#0056B3; text-decoration:underline;\"\u003eEngineering Blog\u003c\/a\u003e\n\u003c\/p\u003e\n","brand":"ABB","offers":[{"title":"Default Title","offer_id":46413436321977,"sku":"406661834466","price":2114.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0268\/8476\/7929\/files\/1_4b0fbd8a-ec3e-460e-a9ff-851c61539a7b.webp?v=1774872954","url":"https:\/\/koeed.com\/es\/products\/1pcs-abb-inverter-acs310-03u-34a1-4","provider":"KOEED","version":"1.0","type":"link"}