{"product_id":"1pcs-ic695pnc001-ak-90days-warranty-via-dhl-or-fedex","title":"GE Fanuc IC695PNC001-AK Ethernet Module","description":"\u003ch1 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:28px; line-height:36px; margin:0 0 8px 0;\"\u003e\n  GE Fanuc IC695PNC001-AK — PROFINET Controller for PACSystems RX3i\n\u003c\/h1\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#0056B3; font-size:14px; line-height:22px;\n          letter-spacing:1px; text-transform:uppercase; margin:0 0 24px 0;\"\u003e\n  GE Fanuc · PACSystems RX3i · PROFINET IO Module · 90-Day Warranty\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:0 0 16px 0;\"\u003e\n  The \u003cstrong\u003eIC695PNC001-AK\u003c\/strong\u003e is a \u003cstrong\u003ePROFINET IO Controller \/ Device module\u003c\/strong\u003e for the\n  \u003ca href=\"\/fr\/collections\/pacsystems-rx3i\" style=\"color:#0056B3; text-decoration:underline;\"\u003eGE Fanuc PACSystems RX3i\u003c\/a\u003e\n  rack. It plugs into a standard RX3i backplane and provides a high-speed PROFINET interface to a\n  PROFINET field network of distributed I\/O, valve manifolds, drives, and third-party controllers.\n  The \u003ccode\u003e-AK\u003c\/code\u003e suffix designates a specific firmware revision\/bundle; engineers standardizing\n  on a single firmware line should verify the build number against their existing CPU before ordering.\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:0 0 16px 0;\"\u003e\n  The IC695PNC001 sits inside KOEED's nine-brand matrix of\n  \u003ca href=\"\/fr\/collections\/ge-fanuc-emerson\" style=\"color:#0056B3; text-decoration:underline;\"\u003eGE Fanuc \/ Emerson\u003c\/a\u003e\n  PACSystems stock and is positioned for European-style fieldbus rollouts where PROFINET is mandated\n  on the machine or line. It is commonly cross-referenced against\n  \u003ca href=\"\/fr\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens S7-1500 PN\u003c\/a\u003e,\n  Allen-Bradley CompactLogix ENET, and Schneider M580 BMENOC controllers.\n\u003c\/p\u003e\n\n\u003c!-- ============ Key Specifications ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Key Specifications\n\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #eeeeee;\n              font-family:Arial, Helvetica, sans-serif; font-size:14px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003e\n        Brand\n      \u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003e\n        GE Fanuc \/ Emerson Automation (PACSystems)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003e\n        Series\n      \u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003e\n        IC695 — PACSystems RX3i\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003e\n        Part Number\n      \u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003e\n        IC695PNC001-AK (firmware revision -AK)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003e\n        Module Type\n      \u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003e\n        PROFINET IO Controller \/ Device (Ethernet Communication Module)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003e\n        Backplane\n      \u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003e\n        IC695 RX3i universal backplane (IC695CHSxxx)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003e\n        Protocol\n      \u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003e\n        PROFINET IO (RT \/ IRT) — refer to datasheet for conformance class\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003e\n        Ethernet Ports\n      \u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003e\n        Refer to datasheet (typical dual RJ45 PROFINET port configuration)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003e\n        Max PROFINET Devices\n      \u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003e\n        Refer to datasheet (controller scaling depends on CPU and firmware)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003e\n        Configuration Software\n      \u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003e\n        PAC Machine Edition (PME) — PROFINET plug-in\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003e\n        Compatible CPU\n      \u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003e\n        IC695CPUxxx (RX3i CPU with PROFINET-enabled firmware)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003e\n        Operating Temperature\n      \u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003e\n        0 °C to 60 °C (refer to datasheet for derating curves)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003e\n        Warranty\n      \u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003e\n        90 days — quoted in advance, worldwide shipping via DHL \/ FedEx\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003e\n        Stock Status\n      \u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003e\n        In stock — quote within 24 hours at \u003ca href=\"mailto:Moritta@KOEED.COM\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c!-- ============ Datasheet Highlights ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Datasheet Highlights\n\u003c\/h2\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePROFINET IO Controller and Device in one module.\u003c\/strong\u003e The IC695PNC001 supports both controller-side operation (mastering a PROFINET subnet of slaves) and device-side operation (advertising the RX3i as a PROFINET device to an external controller), giving system integrators flexibility when retrofitting RX3i into mixed-vendor cells.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard RX3i backplane installation.\u003c\/strong\u003e Mounts in any IC695CHSxxx universal backplane slot adjacent to a supported RX3i CPU. Slot rules and backplane power budget must be checked against the rack's existing I\/O population.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePAC Machine Edition (PME) configuration.\u003c\/strong\u003e Programming, GSDML import, device naming, and IP assignment are all handled inside PME through the PROFINET plug-in. Existing RX3i projects can be re-targeted by adding the module to the hardware configuration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFirmware revision locked by the -AK suffix.\u003c\/strong\u003e The \u003ccode\u003e-AK\u003c\/code\u003e bundle is a specific firmware build. When replacing a module in a running system, the firmware revision should match (or be made consistent with) the rest of the rack to avoid surprise behavior at startup. KOEED can confirm the build number on the unit we ship before invoicing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEuropean-style fieldbus standard.\u003c\/strong\u003e PROFINET is the dominant industrial Ethernet protocol in European machine building. If your line ships to EU end-customers, integrating PROFINET into the RX3i master removes the need for vendor-specific gateways on the cell.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:16px 0 0 0;\"\u003e\n  For exact port count, max device count, update time, conformance class, and IRT support, please\n  request the IC695PNC001-AK datasheet from\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=Datasheet%20%E2%80%94%20IC695PNC001-AK\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e\n  before commissioning.\n\u003c\/p\u003e\n\n\u003c!-- ============ Typical Applications ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Typical Applications\n\u003c\/h2\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEuropean-spec machine builds.\u003c\/strong\u003e OEM machine builders shipping packaging, filling, labeling, and material handling machines into EU end-users where PROFINET is the customer-mandated fieldbus.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePROFINET distributed I\/O islands.\u003c\/strong\u003e Connecting Siemens ET200, Festo valve manifolds, Balluff IO-Link masters, and Phoenix Contact Axioline stations to a PACSystems RX3i master over a single PROFINET cable plant.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrownfield replacement of failed comm modules.\u003c\/strong\u003e Field service on RX3i racks that have an existing IC695ETM001 or IC695CMM002 and now need to migrate that traffic onto PROFINET as the surrounding plant standardizes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProcess line retrofits.\u003c\/strong\u003e Water \u0026amp; wastewater, food \u0026amp; beverage, and chemical lines where the PLC backbone is RX3i but the field I\/O has been progressively migrated to PROFINET blocks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCell-to-cell PROFINET bridging.\u003c\/strong\u003e Two adjacent RX3i cells, each with an IC695PNC001, exchanging status and hand-shake tags through PROFINET device mode rather than hard-wiring I\/O between racks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAuto-tier cross-vendor cells.\u003c\/strong\u003e A RX3i master coordinating a PROFINET sub-network that includes third-party controllers (Siemens ET200S, ABB AC500) acting as PROFINET devices to the RX3i master.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c!-- ============ Related Modules \u0026 Cross-Reference ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Related Modules \u0026amp; Cross-Reference\n\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #eeeeee;\n              font-family:Arial, Helvetica, sans-serif; font-size:14px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee;\n                 color:#111111; font-weight:bold;\"\u003eSame family (RX3i PROFINET \/ Ethernet)\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        \u003ca href=\"\/fr\/products\/ic695pnc001\" style=\"color:#0056B3; text-decoration:underline;\"\u003eIC695PNC001\u003c\/a\u003e (base firmware) ·\n        \u003ca href=\"\/fr\/products\/ic695etm001\" style=\"color:#0056B3; text-decoration:underline;\"\u003eIC695ETM001\u003c\/a\u003e (Ethernet TCP\/IP module) ·\n        \u003ca href=\"\/fr\/products\/ic695cmm002\" style=\"color:#0056B3; text-decoration:underline;\"\u003eIC695CMM002\u003c\/a\u003e (serial \/ H\u0026amp;E)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee;\n                 color:#111111; font-weight:bold;\"\u003eRX3i CPU \u0026amp; power\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        \u003ca href=\"\/fr\/products\/ic695cpu310\" style=\"color:#0056B3; text-decoration:underline;\"\u003eIC695CPU310\u003c\/a\u003e ·\n        \u003ca href=\"\/fr\/products\/ic695cpu315\" style=\"color:#0056B3; text-decoration:underline;\"\u003eIC695CPU315\u003c\/a\u003e ·\n        \u003ca href=\"\/fr\/products\/ic695psa040\" style=\"color:#0056B3; text-decoration:underline;\"\u003eIC695PSA040\u003c\/a\u003e (power supply)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee;\n                 color:#111111; font-weight:bold;\"\u003eRX3i I\/O\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        \u003ca href=\"\/fr\/products\/ic695alg600\" style=\"color:#0056B3; text-decoration:underline;\"\u003eIC695ALG600\u003c\/a\u003e (analog input) ·\n        \u003ca href=\"\/fr\/products\/ic695alg704\" style=\"color:#0056B3; text-decoration:underline;\"\u003eIC695ALG704\u003c\/a\u003e (analog output) ·\n        \u003ca href=\"\/fr\/products\/ic695mdl664\" style=\"color:#0056B3; text-decoration:underline;\"\u003eIC695MDL664\u003c\/a\u003e (digital input)\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee;\n                 color:#111111; font-weight:bold;\"\u003eCross-reference (other brands)\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        \u003ca href=\"\/fr\/collections\/profinet-modules\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens S7-1500 PN CPU\u003c\/a\u003e ·\n        \u003ca href=\"\/fr\/collections\/profinet-modules\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley CompactLogix ENET\u003c\/a\u003e ·\n        \u003ca href=\"\/fr\/collections\/profinet-modules\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider M580 BMENOC\u003c\/a\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee;\n                 color:#111111; font-weight:bold;\"\u003eMigration guide\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        \u003ca href=\"\/fr\/pages\/rx3i-migration-guide\" style=\"color:#0056B3; text-decoration:underline;\"\u003eRX3i vs RX7i migration\u003c\/a\u003e ·\n        \u003ca href=\"\/fr\/pages\/rx3i-migration-guide\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePROFINET to Ethernet\/IP bridging\u003c\/a\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c!-- ============ Warranty \u0026 Authenticity ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Warranty \u0026amp; Authenticity\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003e\n  Each IC695PNC001-AK is inspected, electrically tested on a PACSystems RX3i bench, and visually\n  verified for label and revision consistency before it leaves the warehouse. We document the\n  firmware build on the unit we ship and share it with you in the quote so you can match it to\n  the rest of the rack before commissioning.\n\u003c\/p\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003e90-day warranty\u003c\/strong\u003e on the IC695PNC001-AK, starting at invoice date. Warranty terms cover DOA \/ out-of-box failure and early-life defects on a repair-or-replace basis.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWorldwide shipping\u003c\/strong\u003e by DHL or FedEx, with tracking. Export documentation and commercial invoice are included for customs clearance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e24-hour quote turnaround\u003c\/strong\u003e on business days. Send the part number, quantity, project country, and required firmware build to \u003ca href=\"mailto:Moritta@KOEED.COM\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e and we come back with availability and a price on the same business day.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBulk pricing for system integrators\u003c\/strong\u003e — if you are rolling out multiple RX3i cells on a single project, send the full BOM and we will quote the whole list as one package.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHard-to-find and EOL support\u003c\/strong\u003e — PACSystems RX3i modules, including older PROFINET and Ethernet communication catalog numbers, are one of our stocking specialties.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:16px 0 0 0;\"\u003e\n  KOEED is an independent multi-brand industrial automation distributor covering\n  \u003cstrong\u003eAllen-Bradley, Siemens, Mitsubishi, Omron, Fanuc, Schneider, Yaskawa, Panasonic, and KEYENCE\u003c\/strong\u003e\n  — the same nine-brand matrix shown on our homepage. We are not an OEM subsidiary of GE Fanuc \/\n  Emerson; we are a sourcing channel that keeps active and legacy catalog numbers side by side so that\n  RX3i users can keep their lines running without re-engineering the rack.\n\u003c\/p\u003e\n\n\u003c!-- ============ Inquiry CTA ============ --\u003e\n\u003cdiv style=\"background-color:#16c8c8; padding:24px 32px; margin:32px 0; text-align:center;\n            font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003ch3 style=\"margin:0 0 12px 0; color:#ffffff; font-size:20px; line-height:28px;\"\u003e\n    Need an IC695PNC001-AK or a full RX3i BOM?\n  \u003c\/h3\u003e\n  \u003cp style=\"margin:0 0 16px 0; color:#ffffff; font-size:15px; line-height:22px;\"\u003e\n    Send your part list to \u003cstrong\u003eMoritta@KOEED.COM\u003c\/strong\u003e and get availability + price within 24 hours.\n  \u003c\/p\u003e\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20IC695PNC001-AK\" style=\"display:inline-block; background-color:#ffffff; color:#0056B3; padding:12px 24px;\n            text-decoration:none; font-weight:bold; border-radius:4px; font-size:15px;\"\u003e\n    Request a Quote →\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"border:1px solid #0056B3; padding:16px 24px; margin:16px 0; text-align:left;\n            font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 8px 0; color:#111111; font-size:15px; line-height:22px;\"\u003e\n    Looking for more in the same series?\n  \u003c\/p\u003e\n  \u003ca href=\"\/fr\/collections\/pacsystems-rx3i\" style=\"display:inline-block; color:#0056B3; padding:6px 18px;\n            text-decoration:none; font-weight:bold; border:1px solid #0056B3;\n            border-radius:4px; font-size:14px;\"\u003e\n    Browse PACSystems RX3i modules →\n  \u003c\/a\u003e\n   \n  \u003ca href=\"\/fr\/collections\/profinet-modules\" style=\"display:inline-block; color:#0056B3; padding:6px 18px;\n            text-decoration:none; font-weight:bold; border:1px solid #0056B3;\n            border-radius:4px; font-size:14px;\"\u003e\n    Browse PROFINET modules →\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"border:1px solid #eeeeee; background-color:#f4fcfc; padding:16px 24px; margin:16px 0;\n            font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 4px 0; color:#111111; font-size:15px; font-weight:bold;\"\u003e\n    \u0026gt; Sourcing a full RX3i rack?\n  \u003c\/p\u003e\n  \u003cp style=\"margin:0 0 8px 0; color:#333333; font-size:14px;\"\u003e\n    Send the CPU, power supply, I\/O, and communication module list as one BOM — we quote the whole rack in a single email.\n  \u003c\/p\u003e\n  \u003ca href=\"\/fr\/pages\/request-for-quote\" style=\"color:#0056B3; text-decoration:underline; font-weight:bold; font-size:14px;\"\u003e\n    Open the Create a Quote form\n  \u003c\/a\u003e\n\u003c\/div\u003e\n","brand":"KOEED","offers":[{"title":"Default Title","offer_id":43706688241849,"sku":"364710215941","price":1941.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0268\/8476\/7929\/files\/s-l1600_f4350e1c-75a9-4ecd-9dde-a97bfeccf594.jpg?v=1708566447","url":"https:\/\/koeed.com\/fr\/products\/1pcs-ic695pnc001-ak-90days-warranty-via-dhl-or-fedex","provider":"KOEED","version":"1.0","type":"link"}