KLÜBER to Mobil High-Temperature Grease Cross-Reference Table
| KLÜBER Product | Equivalent Product | Compatibility & Notes |
| Kluberlub BE 71-501 | Mobilith SHC 220 | Bentonite vs lithium complex. BE 71-501 rated to 200°C continuous vs SHC 220 to 150°C. Not equivalent. |
| Barrierta L 55/2 | Mobilgrease 28 | PFPE/PTFE vs clay-thickened synthetic hydrocarbon. Barrierta L to 260°C vs Mobilgrease 28 to 180°C. Not equivalent. |
| PETAMO GHY 441 | Mobilith SHC 220 | Both lithium complex. PETAMO rated to 180°C continuous vs SHC 220 to 150°C. |
| Klübertemp HM 83-402 | Mobilgrease 28 | PTFE/silicone vs clay/synthetic hydrocarbon. Klübertemp to 220°C. Different thickener and base oil technologies. |
Reference: Published product datasheets from KLÜBER Lubrication and Mobil. Verify with current datasheets before substitution.
⚠ Important Disclaimer
This cross-reference is provided for informational purposes only. Equivalent does not mean identical — differences in thickener type, base oil viscosity, additive packages, and NLGI grade can affect performance. Always verify technical compatibility by consulting both manufacturers' datasheets and obtaining OEM approval before substituting lubricants. Contact KOEED for verified KLÜBER product recommendations matched to your specific application requirements.
> Tip
When cross-referencing, always verify: (1) thickener compatibility — mixing incompatible thickeners can cause grease to soften or harden, (2) base oil viscosity at operating temperature, (3) NLGI grade for proper consistency, (4) certification status (NSF H1, ISO 21469) for food-grade applications. If in doubt, contact KOEED for a verified recommendation.
Frequently Asked Questions
Q: What is Mobil's highest-temperature grease?
Mobilgrease 28 is a clay-thickened synthetic hydrocarbon grease rated to approximately 180°C maximum continuous. For temperatures above 180°C, KLÜBER offers Kluberlub BE 71-501 (bentonite, to 200°C), Klübertemp HM 83-402 (PTFE/silicone, to 220°C), and Barrierta L 55/2 (PFPE/PTFE, to 260°C) — all exceeding Mobil's maximum temperature capability.