The Carel BL0T3B00H0 represents the pinnacle of industrial humidification technology, designed specifically for integration with PLC-controlled automation systems. This steam cylinder is engineered for precision humidity control in demanding industrial environments.
Product Overview
The BL0T3B00H0 is a three-phase steam cylinder designed for Carel's HumiSteam isothermal immersed electrode humidifiers. This industrial-grade component plays a crucial role in maintaining optimal humidity levels in various industrial applications, from manufacturing facilities to data centers and clean rooms.
Product Demonstration Video
Technical Specifications
Parameter
Specification
Details
Product Type
Steam Cylinder
For HumiSteam isothermal immersed electrode humidifier
Manufacturer
Carel
Leading industrial humidification solutions provider
Capacity
10-15 kg/h
Three-phase operation
Cylinder Type
Type B
Standard disposable cylinder
Cylinder Rating
B - conductivity from 75
Optimized for specific water conductivity levels
Humidification
30 mm (1.18 in)
Precision steam generation
Warranty Period
3 to 12 Months
Varies by supplier and application
Dimensions
16.4 inches (41.656 cm)
Height specification
Diameter
9.9 inches (25.146 cm)
Standard industrial size
Weight
4.46 kg
Approximate shipping weight
Phase Configuration
Three-phase
Industrial power requirements
PLC Compatibility
Full Integration
Designed for automated control systems
Key Features and Benefits
Industrial-Grade Performance
The BL0T3B00H0 steam cylinder delivers reliable 10-15 kg/h humidification capacity, making it ideal for medium to large industrial applications. Its three-phase design ensures stable operation in demanding environments.
PLC Integration Capabilities
This steam cylinder is specifically designed for seamless integration with PLC-controlled automation systems. It features standardized interfaces and control protocols that allow for:
Precise humidity level monitoring and control
Automated maintenance scheduling
Real-time performance monitoring
Integration with building management systems (BMS)
Remote monitoring and control capabilities
Advanced Safety Features
The Carel BL0T3B00H0 incorporates multiple safety mechanisms including:
Over-temperature protection
Low water level detection
Electrical safety interlocks
Automatic shut-off systems
Ground fault protection
Industrial Applications
Manufacturing Facilities
Maintain optimal humidity levels for production processes, preventing static electricity and ensuring product quality in electronics, pharmaceutical, and precision manufacturing.
Data Centers
Protect sensitive electronic equipment from electrostatic discharge and maintain optimal operating conditions for servers and networking equipment.
Clean Rooms
Provide precise humidity control for pharmaceutical, semiconductor, and biotechnology facilities where environmental conditions are critical.
Commercial Buildings
Enhance indoor air quality and comfort in office buildings, hospitals, museums, and archives where humidity control is essential.
Installation and Maintenance
The BL0T3B00H0 steam cylinder is designed for straightforward installation and maintenance:
Pre-installation Check: Verify power supply compatibility and water quality
Mounting: Secure in designated humidifier housing
Electrical Connection: Connect three-phase power supply following local electrical codes
Water Connection: Connect to appropriate water supply with proper filtration
PLC Integration: Connect control signals to automation system
Testing: Perform functional tests and calibration
Frequently Asked Questions (FAQ)
What is the typical lifespan of the BL0T3B00H0 steam cylinder?
The steam cylinder typically lasts 3-12 months depending on water quality, usage frequency, and maintenance practices. Regular monitoring and proper water treatment can extend its lifespan.
Can this steam cylinder be integrated with existing PLC systems?
Yes, the BL0T3B00H0 is designed for seamless integration with most industrial PLC systems. It features standard control interfaces and can be programmed for automated operation.
What water quality is required for optimal performance?
The Type B cylinder is rated for water conductivity from 75 μS/cm. For best results, use properly treated water with appropriate conductivity levels and minimal mineral content.
How does the three-phase design benefit industrial applications?
Three-phase operation provides more stable power distribution, higher efficiency, and better performance consistency compared to single-phase systems, making it ideal for continuous industrial operation.
What maintenance is required for this steam cylinder?
Regular maintenance includes monitoring water quality, checking electrical connections, and replacing the cylinder as needed based on performance indicators and PLC monitoring data.
Trust and Quality Assurance
Manufacturer Reputation: Carel is a globally recognized leader in industrial humidification solutions with over 40 years of experience.
Certifications: Products comply with international standards including CE, UL, and RoHS directives.
Industry Adoption: Widely used in critical applications across multiple industries including pharmaceuticals, data centers, and manufacturing.
Technical Support: Comprehensive technical documentation and manufacturer support available.
Warranty Coverage: Standard warranty periods from 3 to 12 months depending on supplier and application.
Technical References and Resources
For additional technical information and support:
Manufacturer Documentation: Complete technical manuals available from Carel
PLC Integration Guides: Specific protocols for major automation platforms
Maintenance Schedules: Recommended service intervals and procedures
Troubleshooting Guides: Common issues and solutions
Important Considerations
When implementing the BL0T3B00H0 in your automation system:
Ensure proper water treatment to extend cylinder life
Verify electrical compatibility with local power standards
Implement proper PLC programming for automated control
Establish regular maintenance schedules
Monitor performance through your automation system
Conclusion
The Carel BL0T3B00H0 steam cylinder represents a sophisticated solution for industrial humidification needs, offering reliable performance, seamless PLC integration, and robust construction for demanding applications. Its 10-15 kg/h capacity and three-phase design make it suitable for a wide range of industrial environments where precise humidity control is essential for process quality, equipment protection, and operational efficiency.
By integrating this component into your PLC-controlled automation system, you can achieve precise environmental control, reduce maintenance costs, and ensure consistent performance in your industrial operations.
The CP-2FK(b)J is a high-precision conductive plastic angle sensor from Midori's CP-2FK series, featuring 340° effective electrical travel, ±1% independent linearity, ball bearing construction, and servo mount installation. This industrial-grade...
The CP-2FK(b)J is a high-precision conductive plastic angle sensor from Midori's CP-2FK series, featuring 340° effective electrical travel, ±1% independent linearity, ball bearing construction, and servo mount installation. This industrial-grade...
The Mitsubishi CNV2E-9P-8M is a professional-grade 8-meter encoder cable designed for CNC servo motor applications in industrial automation. Featuring pure copper conductors with gold-plated contacts, this specialized cable ensures reliable...
The Mitsubishi CNV2E-9P-8M is a professional-grade 8-meter encoder cable designed for CNC servo motor applications in industrial automation. Featuring pure copper conductors with gold-plated contacts, this specialized cable ensures reliable...
The Tungaloy CNMG120408-SM T6130 is a premium carbide turning insert specifically engineered for industrial automation applications, featuring specialized T6130 grade carbide, SM chipbreaker geometry, and optimized performance for steel and...
The Tungaloy CNMG120408-SM T6130 is a premium carbide turning insert specifically engineered for industrial automation applications, featuring specialized T6130 grade carbide, SM chipbreaker geometry, and optimized performance for steel and...