Rosemount 3051TG4A2B21AK6M5: checks before ordering

Historical parts record: Photos and notes below belong to this record. Confirm the offered unit’s full model, condition and available test evidence before ordering.

Does 3051TG4 specify a 0 to 150 psig span?

No. Emerson’s cited ordering table identifies gauge-pressure range code 4 as −14.7 to 4000 psi. The original listing describes a unit configured for 0 to 150 psig; that configured span must be verified on the offered unit. Quote the complete model 3051TG4A2B21AK6M5 and check its calibration label and configuration record.

3 min readContent reviewed
Rosemount 3051TG4A2B21AK6M5 product photograph from KOEED
Rosemount 3051TG4A2B21AK6M5. Photograph from the KOEED product listing; confirm the offered packaging and unit with the quotation.

Range code 4 does not mean 0 to 150 psig

The original listing describes a unit configured for 0 to 150 psig. That is a configuration to verify on the supplied unit. Emerson's 3051T ordering table lists the gauge-pressure range code 4 as −14.7 to 4000 psi. It does not define every 3051TG4 transmitter as a 0 to 150 psig instrument.

Ask for the configured lower and upper range values and the required accuracy at that span. A broad sensor range does not establish the accuracy of a particular narrow-span application.

Read the option code with the correct ordering table

Read the option code with the correct ordering table
Code or record What it tells you
3051T The in-line transmitter family.
G and range code 4 Gauge-pressure measurement and the sensor-range selection.
Output code A 4 to 20 mA with HART digital communication in the cited ordering table.
K6 An approval combination in the cited table. It is not a housing or conduit-thread code.
Full nameplate and order record The evidence needed to confirm connection, materials, enclosure, display and approval options for the supplied unit.

Scroll the table horizontally to view all columns.

Source: Emerson: Rosemount 3051 product data sheet. Use the applicable model and the conditions stated in the source.

Match the ordering information to the transmitter's version and its own approval label. A certificate offered somewhere in the 3051 family does not prove that it applies to a particular unit or installation.

Information to send with an enquiry

Include a readable nameplate photograph, the required calibrated span and pressure units, process medium, process connection and electrical interface. State any hazardous-area, material or documentation requirements explicitly.

Request photographs of the offered unit and confirm whether calibration documentation is included. Record the condition, accessories and commercial warranty terms in the quotation. The model designation alone does not establish those terms.

Installation and maintenance records

Use the applicable Emerson manual and site procedures for installation and testing. Confirm material suitability for the actual process medium, temperature and pressure. Set inspection and calibration intervals from the application's requirements and performance history.

The photographs and video retained below document the original listing. Confirm the label and configuration of the unit being offered before ordering.

Original listing photographs and video

Rosemount 3051TG4A2B21AK6M5 original listing photograph 1
Rosemount 3051TG4A2B21AK6M5 original listing photograph 2
Rosemount 3051TG4A2B21AK6M5 original listing photograph 3
Rosemount 3051TG4A2B21AK6M5 original listing photograph 4
Rosemount 3051TG4A2B21AK6M5 original listing photograph 5
Rosemount 3051TG4A2B21AK6M5 original listing photograph 6
Rosemount 3051TG4A2B21AK6M5 original listing photograph 7
Rosemount 3051TG4A2B21AK6M5 original listing photograph 8
Rosemount 3051TG4A2B21AK6M5 original listing photograph 9
Rosemount 3051TG4A2B21AK6M5 original listing photograph 10
Rosemount 3051TG4A2B21AK6M5 original listing photograph 11
Rosemount 3051TG4A2B21AK6M5 original listing photograph 12

Check the offered Rosemount configuration

Send the full model code, required pressure span, quantity and approval requirements. Request clear nameplate and calibration-label photographs with the quotation.

Manufacturer references

Need a quote for this part?

Send us the part number or article link — we will confirm price, availability and lead time.

WhatsApp us

Related Articles

Kembali ke blog