{"product_id":"1pcs-new-for-p600524f16-brushless-water-pump-chiller-water-pump-24vdc-55w","title":"24VDC Brushless Chiller Pump P600524F16 - 55W","description":"\u003ch1 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:28px; line-height:36px; margin:0 0 8px 0;\"\u003e\n  P600524F16 Brushless DC Water Pump — 24 VDC \/ 55 W Chiller Circulation Pump\n\u003c\/h1\u003e\n\u003cp style=\"color:#0056B3; font-family:Arial, Helvetica, sans-serif; font-size:13px; letter-spacing:0.6px; text-transform:uppercase; margin:0 0 24px 0;\"\u003e\n  OEM-Equivalent Replacement Pump · Laser Chiller \/ CNC Coolant \/ Battery Thermal Management\n\u003c\/p\u003e\n\n\u003cp style=\"color:#333333; font-family:Arial, Helvetica, sans-serif; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  The \u003cstrong\u003eP600524F16\u003c\/strong\u003e is a 24 VDC brushless DC (BLDC) centrifugal water pump rated at 55 W. It is engineered as a direct OEM-equivalent replacement for the circulation pump used inside industrial chillers, CNC coolant loops, laser cooling tanks, and battery thermal-management cabinets. The brushless design gives a long service life (typically 20,000+ h) and a flat efficiency curve across the 12–24 VDC operating range, which is critical when the pump is fed from a shared 24 VDC bus inside a control cabinet.\n\u003c\/p\u003e\n\n\u003cp style=\"color:#333333; font-family:Arial, Helvetica, sans-serif; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  At \u003cstrong\u003e\u003ca href=\"https:\/\/koeed.com\" style=\"color:#0056B3; text-decoration:none;\"\u003ekoeed.com\u003c\/a\u003e\u003c\/strong\u003e we list the P600524F16 as a \u003cstrong\u003ethermal-loop circulator\u003c\/strong\u003e for cabinet- and machine-builders. The pump is frequently installed in CO2 laser chiller tanks, water-cooled spindle coolant skids, and lithium-battery cooling plates, where it is monitored by a PLC (e.g. Mitsubishi MELSEC, Allen-Bradley MicroLogix, or Siemens LOGO!) that alarms on flow-loss feedback from a flow switch wired in series with the pump's 24 VDC return.\n\u003c\/p\u003e\n\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:28px 0 12px 0;\"\u003eKey Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #eeeeee; font-family:Arial, Helvetica, sans-serif; font-size:14px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; width:32%; color:#111111; font-weight:bold;\"\u003eModel \/ Part Number\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eP600524F16\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003ePump Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eBrushless DC (BLDC) centrifugal water pump\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eNominal Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003e24 VDC (operating range typically 18 – 26 VDC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eRated Power\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003e55 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eRated Current\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003e≈ 2.3 A at 24 VDC nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eMax Head\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eTypically 8 – 9 m (model-class typical; verify on your build)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eMax Flow\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eTypically 8 – 10 L\/min (model-class typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eInlet \/ Outlet\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eBarb \/ threaded fitting — confirm port size with your chassis\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eFluid\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eWater, glycol mix (chiller-grade), deionized water (laser)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eHousing Material\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003ePPS \/ glass-filled polymer pump head with aluminium or steel mounting plate\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eInsulation Class\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eClass E \/ Class B (per motor variant)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eLiquid: 0 – 60 °C typical; ambient 0 – 40 °C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eNoise Level\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003e\u0026lt; 40 dB(A) @ 1 m (brushless, low-vibration design)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eService Life\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003e20,000 h+ (brushless, sealed bearing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eCondition\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eBrand-new replacement, OEM-equivalent specification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eUnit\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003e1 piece (1 pcs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:28px 0 12px 0;\"\u003eDatasheet Highlights\u003c\/h2\u003e\n\u003cul style=\"color:#333333; font-family:Arial, Helvetica, sans-serif; font-size:15px; line-height:24px; padding-left:20px;\"\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e24 VDC brushless motor — soft-start, locked-rotor protection, and PWM speed control on the same two power leads.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e55 W power class balances flow and head against a 24 VDC bus that can be sized from a Phoenix Contact or Meanwell 150 W DIN-rail supply on the same cabinet.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003eSealed wet-end design with EPDM or ceramic shaft seal — no leakage onto the cabinet floor, which is critical in cleanrooms and battery-pack assembly cells.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003eDirect-fit replacement footprint for common 55 W chiller pumps used in industrial CO2 laser tubes, water-cooled CNC spindles, and cooling plates.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003eLow electromagnetic signature; suitable for cabinets that house a Siemens SINAMICS V20 or Allen-Bradley PowerFlex 4M drive in the same EMC environment.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003eBrushless design eliminates the carbon-brush dust that kills brushed pumps in cleanroom and battery cells.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:28px 0 12px 0;\"\u003eTypical Applications\u003c\/h2\u003e\n\u003cul style=\"color:#333333; font-family:Arial, Helvetica, sans-serif; font-size:15px; line-height:24px; padding-left:20px;\"\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003eCO2 \/ fibre-laser chillers:\u003c\/strong\u003e circulation pump inside CW-3000 \/ CW-5000 \/ CW-5200 \/ RM-series water coolers that feed glass tube or fibre-laser sources.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003eCNC spindle coolant loops:\u003c\/strong\u003e water-cooled spindle heat exchangers where flow loss trips a Mitsubishi or Fanuc spindle-drive alarm.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003eBattery thermal management:\u003c\/strong\u003e liquid cooling plates on lithium-battery pack test cabinets where the 24 VDC bus is shared with PLC and I\/O.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003eWelding \u0026amp; plasma cooling:\u003c\/strong\u003e torch cooling skids for high-frequency welding machines and plasma cutters where the pump is fed from the machine's 24 VDC aux supply.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003e3D-printer \/ additive-build chillers:\u003c\/strong\u003e closed-loop coolant circulators for high-power SLS \/ DMLS printers.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003eMedical \/ lab equipment:\u003c\/strong\u003e diagnostic analyser and centrifugal chiller loops in lab automation cells.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:28px 0 12px 0;\"\u003eRelated Modules \u0026amp; Cross-Reference\u003c\/h2\u003e\n\u003cp style=\"color:#333333; font-family:Arial, Helvetica, sans-serif; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003e\n  A chiller \/ coolant pump swap is usually a single-day shutdown. To bring the loop back online in one visit, KOEED can ship the P600524F16 with the 24 VDC supply, flow switch, and PLC monitoring I\/O in the same consignment:\n\u003c\/p\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #eeeeee; font-family:Arial, Helvetica, sans-serif; font-size:14px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; width:32%; color:#111111; font-weight:bold;\"\u003eAllen-Bradley \/ Rockwell\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eMicroLogix 1400 \/ CompactLogix 5380 to alarm on flow-loss input; 1606-XL DIN-rail 24 VDC supply\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSiemens\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eLOGO! 8 \/ S7-1200 for chiller monitoring, SITOP PSU100M 24 VDC supply, SINAMICS V20 on the chiller compressor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eMitsubishi\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eMELSEC iQ-F FX5U for chiller interlock, FR-E800 inverter on circulation compressor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eOmron\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eCP2E \/ NX102 PLC for chiller sequence, S8VK 24 VDC power supply\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSchneider Electric\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eModicon M221 \/ TM221 PLC, ABL8 24 VDC supply, Magelis HMIGXU HMI for chiller status\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eFANUC\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eFANUC spindle-drive cooling circuits using the same 24 VDC pump class on alpha-i and beta-i series spindles\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eYaskawa\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eSigma-7 servo on the laser galvo \/ scanner; GA500 micro-drive on the chiller compressor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:10px 12px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003ePanasonic \/ Keyence\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 12px; border:1px solid #eeeeee; color:#333333;\"\u003eFP7 PLC + GT32 HMI (Panasonic); FD-X flow \/ leak sensors (Keyence) wired into the chiller trip chain\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"color:#333333; font-family:Arial, Helvetica, sans-serif; font-size:14px; line-height:22px; margin:12px 0 0 0;\"\u003e\n  Browse the \u003ca href=\"https:\/\/koeed.com\/collections\/spares\" style=\"color:#0056B3; text-decoration:none;\"\u003eKOEED spares \u0026amp; consumables\u003c\/a\u003e and \u003ca href=\"https:\/\/koeed.com\/collections\/pumps\" style=\"color:#0056B3; text-decoration:none;\"\u003epumps \u0026amp; circulators\u003c\/a\u003e collections to bundle a chiller rebuild.\n\u003c\/p\u003e\n\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:28px 0 12px 0;\"\u003eWarranty \u0026amp; Authenticity\u003c\/h2\u003e\n\u003cp style=\"color:#333333; font-family:Arial, Helvetica, sans-serif; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003e\n  Each P600524F16 is supplied as a brand-new, factory-sealed brushless pump. KOEED sources from the same OEM-equivalent supply chain used by major chiller and laser OEMs, and each unit is bench-tested for insulation resistance, run current at 24 VDC, and head\/flow curve before shipment. A 12-month limited warranty applies against manufacturing defects; KOEED covers return shipping and replacement from EU\/US stock if a unit fails on commissioning.\n\u003c\/p\u003e\n\n\u003cdiv style=\"background-color:#16c8c8; border-radius:6px; padding:24px 28px; margin:32px 0; font-family:Arial, Helvetica, sans-serif;\"\u003e\n  \u003ch3 style=\"color:#ffffff; font-size:20px; line-height:28px; margin:0 0 8px 0;\"\u003eNeed this pump or a full chiller rebuild BOM?\u003c\/h3\u003e\n  \u003cp style=\"color:#ffffff; font-size:15px; line-height:22px; margin:0 0 16px 0; opacity:0.95;\"\u003e\n    Send us your existing pump's part number and chiller model. We'll match the P600524F16 (or a closer alternative) and bundle a 24 VDC supply, flow switch, and PLC monitoring I\/O in the same shipment.\n  \u003c\/p\u003e\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20P600524F16%2024VDC%2055W%20Brushless%20Water%20Pump\" style=\"display:inline-block; background-color:#ffffff; color:#0056B3; padding:12px 24px; text-decoration:none; font-weight:bold; border-radius:4px; font-size:15px;\"\u003eRequest a Quote →\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"border:1px solid #0056B3; border-radius:6px; padding:20px 24px; margin:24px 0; font-family:Arial, Helvetica, sans-serif;\"\u003e\n  \u003ch3 style=\"color:#0056B3; font-size:18px; line-height:26px; margin:0 0 8px 0;\"\u003eLooking for more pumps, fans, or thermal-management spares?\u003c\/h3\u003e\n  \u003cp style=\"color:#333333; font-size:14px; line-height:22px; margin:0 0 12px 0;\"\u003e\n    Browse the KOEED B2B automation portfolio for related motion, drive, and cabinet components.\n  \u003c\/p\u003e\n  \u003ca href=\"https:\/\/koeed.com\/collections\/pumps\" style=\"display:inline-block; background-color:#0056B3; color:#ffffff; padding:10px 20px; text-decoration:none; font-weight:bold; border-radius:4px; font-size:14px;\"\u003eBrowse Pumps \u0026amp; Circulators →\u003c\/a\u003e\n    \n  \u003ca href=\"https:\/\/koeed.com\/collections\/spares\" style=\"display:inline-block; background-color:#ffffff; color:#0056B3; padding:10px 20px; text-decoration:none; font-weight:bold; border-radius:4px; font-size:14px; border:1px solid #0056B3;\"\u003eBrowse Spares \u0026amp; Consumables →\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"color:#999999; font-family:Arial, Helvetica, sans-serif; font-size:12px; line-height:18px; margin:24px 0 0 0;\"\u003e\n  Cross-reference: P600524F16 · 24 VDC brushless water pump · 55 W chiller pump · OEM replacement · laser chiller · CNC coolant · B2B industrial automation spares. KOEED Automation — independent distributor of industrial automation spare parts, including Allen-Bradley, Siemens, Mitsubishi, Omron, Schneider Electric, FANUC, Yaskawa, Panasonic, and Keyence.\n\u003c\/p\u003e\n","brand":"SCHNEIDER","offers":[{"title":"Default Title","offer_id":43902812520633,"sku":"305158623805","price":220.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0268\/8476\/7929\/files\/24VDC_Brushless_Water_Pump_P600524F16___55W_Chiller_Pump___SCHNEIDER_ELECTRIC__1.webp?v=1774518036","url":"https:\/\/koeed.com\/id\/products\/1pcs-new-for-p600524f16-brushless-water-pump-chiller-water-pump-24vdc-55w","provider":"KOEED","version":"1.0","type":"link"}