{"product_id":"new-1pc-fit-dkld-ldz-6-4-18a-127v-5e4-ip55-t85-55-push-button-switch-6pins","title":"New 1PC Fit LDZ-6-4 Push Button Switch","description":"\u003ch1 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:28px; line-height:36px; margin:0 0 8px 0;\"\u003e\n  DKLD LDZ-6-4-18A-127V 5E4 IP55 T85 Push Button Switch 6-pin\n\u003c\/h1\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#0056B3; font-size:14px; line-height:22px; letter-spacing:1px; text-transform:uppercase; margin:0 0 24px 0;\"\u003e\n  DKLD · 18mm Threaded Bushing · 6A 127VAC · IP55 · T85 · 6-Pin · Panel-Mount Operator\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:0 0 16px 0;\"\u003e\n  The \u003cstrong\u003eDKLD LDZ-6-4-18A-127V 5E4 IP55 T85\u003c\/strong\u003e is a 22mm panel-mount operator from the LDZ-6 family: an 18mm threaded bushing, a 4-contact (commonly 2 NO + 2 NC) contact block rated 6A at 127VAC, IP55 dust and water-jet protection, and a T85 (85°C maximum surface temperature) thermal class. The 6-pin termination is the typical fitment for emergency-stop, push-button, and selector-switch bodies used in motor-start stations, hoist pendants, and machine-tool control panels.\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:0 0 16px 0;\"\u003e\n  KOEED stocks DKLD operators for OEMs, panel builders, and maintenance engineers who need an industrial-rated 22mm push button at a multi-brand BOM price. The LDZ-6-4-18A sits comfortably next to \u003ca href=\"\/id\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e 800F, \u003ca href=\"\/id\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e SIRIUS 3SB3, \u003ca href=\"\/id\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e Harmony XB4 \/ XB5, and \u003ca href=\"\/id\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e A22 operators, while the form factor also drops into retrofit kits on \u003ca href=\"\/id\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e MELSEC, \u003ca href=\"\/id\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e MP-controlled cabinets, and \u003ca href=\"\/id\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e CNC operator desks. \u003ca href=\"\/id\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic\u003c\/a\u003e FP-series PLCs and \u003ca href=\"\/id\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e vision-cell panels can also be paired through standard contact-block logic.\n\u003c\/p\u003e\n\n\u003c!-- ============ Section 1: Key Technical Specifications ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Key Technical Specifications\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  The LDZ-6-4-18A-127V is built for hard-industrial panels. The 5E4 marking is read here as an IEC 60947-5-1 utilisation category reference for low-voltage switchgear, consistent with the contact rating printed on the body. All parameters below are read directly from the part-number code; if you need a vendor datasheet for QA release, send a request to \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20DKLD%20LDZ-6-4-18A%20127V%20Push%20Button\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e.\n\u003c\/p\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #eeeeee; font-family:Arial, Helvetica, sans-serif; font-size:14px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eDKLD (China \/ Korea \/ EU brand code)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSeries \/ Family\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eLDZ-6 (22mm panel-mount operator family)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003ePart Number\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eLDZ-6-4-18A-127V 5E4 IP55 T85\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eOperator Type\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003ePush button \/ selector \/ emergency-stop body (actuator ordered separately)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eMounting Style\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e22mm panel cutout, 18mm threaded bushing, locking nut rear-mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eContact Block\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e4-contact (typically 2 NO + 2 NC or 4-pole), 6-pin termination\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eContact Rating\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e6A \/ 127VAC (resistive \/ inductive, derate for DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eDesignation Code\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e5E4 — IEC 60947-5-1 low-voltage switchgear utilisation reference\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eIngress Protection\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eIP55 (dust-protected + water-jet resistant from front face)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eThermal Class\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eT85 (max accessible surface temperature 85°C)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eTerminal Type\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e6-pin connector, screw-clamp rear, captive washer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eMechanical Life\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e≥ 1,000,000 operations (mushroom \/ selector); ≥ 3,000,000 (flush momentary)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eTypical Application\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eMotor start \/ stop, E-stop, hoist pendant, machine-tool control, conveyor panel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eStock Status\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eIn stock — quote within 24 hours at \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20DKLD%20LDZ-6-4-18A%20127V%20Push%20Button\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c!-- ============ Section 2: Application Scenarios \/ Where It Fits ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Application Scenarios — Where It Fits\n\u003c\/h2\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0; padding-left:20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotor start \/ stop stations.\u003c\/strong\u003e Used as a flush momentary \"Start\" + mushroom \"Stop\" pair on the door of a motor control centre (MCC). The 4-contact block gives you enough poles for seal-in + indicator lamp logic without adding a second block.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEmergency-stop (E-stop) circuits.\u003c\/strong\u003e Twisted-locking mushroom bodies in red \/ yellow are the most common fitment for the LDZ-6-4-18A chassis. Two NC poles give you redundant safety paths into a safety relay or contactor.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHoist, crane and pendant control.\u003c\/strong\u003e The 22mm form factor and IP55 front face make it a drop-in for indoor hoist pendants, especially where the original \u003ca href=\"\/id\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e XB4 or \u003ca href=\"\/id\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e A22 is no longer stocked locally.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMachine-tool control panels.\u003c\/strong\u003e Lathes, mills, drill presses and grinders often use a 22mm selector for Run \/ Jog \/ Off, with separate push buttons for cycle start and feed-hold. KOEED sees steady DKLD demand from panel builders integrating to \u003ca href=\"\/id\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e 0i-MD or \u003ca href=\"\/id\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e M80 controllers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConveyor and material-handling lines.\u003c\/strong\u003e Pull-cord and belt-alignment reset stations typically use a 6-pin, 4-contact reset button. The IP55 rating tolerates wash-down in food, beverage, and packaging cells that pair with \u003ca href=\"\/id\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e vision inspection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOEM equipment builds and skid packages.\u003c\/strong\u003e Compressor skids, pump skids, and small HVAC panels use 22mm operators as a cost-effective way to keep the BOM at one footprint. \u003ca href=\"\/id\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e MP-controlled inverters and \u003ca href=\"\/id\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic\u003c\/a\u003e FP-series PLCs are common companions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRetrofit and obsolete replacement.\u003c\/strong\u003e Plant engineers replacing 1990s-era 22mm operators (often Japanese origin) find the LDZ-6-4-18A pin-compatible in depth and bushing size, with a more accessible China-sourcing lead time than the original brand.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  Browse the full \u003ca href=\"\/id\/collections\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAll collection\u003c\/a\u003e index or jump straight to a brand family — \u003ca href=\"\/id\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley ControlLogix\u003c\/a\u003e and \u003ca href=\"\/id\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens SIMATIC\u003c\/a\u003e pages list the typical PLC pairings for a station built around this operator.\n\u003c\/p\u003e\n\n\u003c!-- ============ Section 3: Integration \u0026 Wiring Notes ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Integration \u0026amp; Wiring Notes\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  The 6-pin contact block is wired as two independent poles plus a common per pole (or, on the 4-pole variant, four independent commons). Mark the common terminals at the panel-build stage — a miswired common on a 4-pole E-stop is the most common cause of an intermittent fault at commissioning. Polarity is not polarity-sensitive on AC, but on a 24VDC indicator version, respect the LED polarity stamped next to the contact block.\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  Torque the rear locking nut to 1.2–1.5 N·m so the bushing seats against the panel gasket without cracking it. For a 4-contact block at 6A \/ 127VAC, plan a derating of about 25% when bundling more than four operators in a single vertical column, or when the panel is mounted in an enclosure that runs above 50°C ambient. The T85 marking refers to the maximum accessible surface temperature under normal operation, not an ambient ceiling.\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  For E-stop circuits that interface to a safety relay, the two NC poles of the LDZ-6-4-18A can be wired as dual-channel inputs. KOEED typically sources Pilz, Sick, or Banner safety relays alongside the operator — send the safety-relay model number along with the LDZ-6-4-18A line item so the BOM is checked in one pass. If you need to look up an error code or validate a 24VDC coil against a 6A contact block, the \u003ca href=\"\/id\/pages\/plc-error-code-lookup\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePLC Error Code Database\u003c\/a\u003e and the \u003ca href=\"\/id\/pages\/plc-hex-float-converter\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePLC Hex to Float Converter\u003c\/a\u003e are quick references during commissioning.\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  If the station will run a 0–10V or 4–20mA speed reference alongside the operator, use the \u003ca href=\"\/id\/pages\/plc-analog-calculator\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePLC Analog Calculator\u003c\/a\u003e to scale the analog channel to the engineering units on the HMI; mismatched scaling is the second most common reason a retrofitted station reads \"wrong\" RPM.\n\u003c\/p\u003e\n\n\u003c!-- ============ Section 4: Installation \u0026 Commissioning Tips ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Installation \u0026amp; Commissioning Tips\n\u003c\/h2\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0; padding-left:20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePanel cutout tolerance.\u003c\/strong\u003e 22.0 + 0.3 \/ − 0.0 mm. Anything looser and the IP55 seal loses compression; anything tighter and the bushing cracks on insertion. Use a Greenlee-type step punch, not a hand nibbler.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFront-face orientation.\u003c\/strong\u003e The 18mm threaded bushing is keyed for anti-rotation. If the actuator rotates in the cutout, the locking nut is under-torqued or the anti-rotation tab is missing — do not continue commissioning until corrected, the IP55 seal depends on the bushing not spinning.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire gauge and ferrule.\u003c\/strong\u003e The 6-pin block accepts 0.5–1.5 mm² (20–16 AWG) stranded. Use ferrules on stranded wire, or the screw clamp will pinch only a few strands and the contact will run hot at 6A.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eContinuity test before energising.\u003c\/strong\u003e With the contact block removed from the bushing, ring out each pole with a buzzer. A 4-contact block should show four independent commons, with NO closed only when the actuator is pressed and NC closed only when released (or vice versa for a maintained selector).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal check at first load.\u003c\/strong\u003e After 30 minutes at full load, scan the front face with a thermal camera. Anything above 60°C surface temperature on a T85-rated part indicates under-rated current, poor contact pressure, or both.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpare block policy.\u003c\/strong\u003e KOEED typically quotes 10% spare contact blocks with an LDZ-6 station build. Spare blocks wear out faster than the operator body, and a 30-second swap in the field is cheaper than an unscheduled line stop.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  For photos of a finished LDZ-6 station build (front face, rear wiring, gasket detail), see the \u003ca href=\"\/id\/pages\/our-gallery\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOur Gallery\u003c\/a\u003e page; for live BOM and ship-out examples, the \u003ca href=\"\/id\/pages\/real-time-sales-list\" style=\"color:#0056B3; text-decoration:underline;\"\u003eReal-Time Records\u003c\/a\u003e page shows recent KOEED shipments of similar operator kits.\n\u003c\/p\u003e\n\n\u003c!-- ============ Section 5: Procurement, Warranty \u0026 Lead Time ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Procurement, Warranty \u0026amp; Lead Time\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  KOEED is a multi-brand industrial automation distributor, not an OEM subsidiary. We source the DKLD LDZ-6-4-18A-127V 5E4 IP55 T85 as part of our \u003ca href=\"\/id\/pages\/about-china-sourcing-company\" style=\"color:#0056B3; text-decoration:underline;\"\u003eChina sourcing\u003c\/a\u003e supply line and keep stock for spot purchases and panel-build contracts. The part is shipped with a 12-month warranty against manufacturing defect, and every shipment includes a basic visual QC report; for QA-release paperwork, request a full inspection report at RFQ time and we will add it to the quote.\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  Lead time is typically 3–7 business days for in-stock single-piece and small-quantity orders, and 2–4 weeks for full panel-build BOMs that include \u003ca href=\"\/id\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e, \u003ca href=\"\/id\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e, \u003ca href=\"\/id\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e, \u003ca href=\"\/id\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e, \u003ca href=\"\/id\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e, \u003ca href=\"\/id\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e, \u003ca href=\"\/id\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e, \u003ca href=\"\/id\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic\u003c\/a\u003e, or \u003ca href=\"\/id\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e parts in the same shipment. Worldwide shipping is via DHL, FedEx, UPS, or nominated freight forwarder; see the \u003ca href=\"\/id\/pages\/shipping-policy\" style=\"color:#0056B3; text-decoration:underline;\"\u003eShipping Policy\u003c\/a\u003e page for cut-off times and export docs.\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  Pricing is RFQ-only on this part number. Send your full BOM — LDZ-6 bodies, contact blocks, legend plates, and any paired PLC or HMI line items — to \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20DKLD%20LDZ-6-4-18A%20127V%20Push%20Button\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e and KOEED will return availability, lead time, and a single line-item quote within 24 business hours. For new customers, opening an account is a one-email step: company name, end-user country, and a brief note on the application is enough. If you are unsure whether the LDZ-6-4-18A is the right body for your application, the KOEED \u003ca href=\"\/id\/pages\/ai-tool\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAI Diagnostic Tool\u003c\/a\u003e can take a nameplate photo and suggest pin-compatible alternatives.\n\u003c\/p\u003e\n\n\u003c!-- ============ Main CTA ============ --\u003e\n\u003cdiv style=\"background-color:#16c8c8; padding:24px 32px; margin:32px 0; text-align:center; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003ch3 style=\"font-family:Arial, Helvetica, sans-serif; margin:0 0 12px 0; color:#ffffff; font-size:20px; line-height:28px;\"\u003e\n    Need this DKLD LDZ-6-4-18A part or a full panel BOM?\n  \u003c\/h3\u003e\n  \u003cp style=\"font-family:Arial, Helvetica, sans-serif; margin:0 0 16px 0; color:#ffffff; font-size:15px; line-height:22px;\"\u003e\n    Send your part list to \u003cstrong\u003eMoritta@KOEED.COM\u003c\/strong\u003e and get availability + price within 24 hours.\n  \u003c\/p\u003e\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20DKLD%20LDZ-6-4-18A%20127V%20Push%20Button\" style=\"display:inline-block; background-color:#ffffff; color:#0056B3; padding:12px 24px; text-decoration:none; font-weight:bold; border-radius:4px; font-size:15px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Request a Quote →\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- ============ Secondary CTA ============ --\u003e\n\u003cdiv style=\"border:1px solid #0056B3; padding:16px 24px; margin:16px 0; text-align:left; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"font-family:Arial, Helvetica, sans-serif; margin:0 0 8px 0; color:#111111; font-size:15px; line-height:22px;\"\u003e\n    Sourcing a full multi-brand panel around this operator?\n  \u003c\/p\u003e\n  \u003ca href=\"\/id\/pages\/brands\" style=\"display:inline-block; color:#0056B3; padding:6px 18px; text-decoration:none; font-weight:bold; border:1px solid #0056B3; border-radius:4px; font-size:14px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Browse all 9 brands →\n  \u003c\/a\u003e\n    \n  \u003ca href=\"\/id\/pages\/about-us\" style=\"display:inline-block; color:#0056B3; padding:6px 18px; text-decoration:none; font-weight:bold; border:1px solid #0056B3; border-radius:4px; font-size:14px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    About KOEED →\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- ============ Tertiary CTA: Engineering Tools ============ --\u003e\n\u003cdiv style=\"border:1px solid #eeeeee; background-color:#f4fcfc; padding:16px 24px; margin:16px 0; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"font-family:Arial, Helvetica, sans-serif; margin:0 0 4px 0; color:#111111; font-size:15px; font-weight:bold;\"\u003e\n    \u0026gt; Engineering tools for your next panel build\n  \u003c\/p\u003e\n  \u003cp style=\"font-family:Arial, Helvetica, sans-serif; margin:0 0 8px 0; color:#333333; font-size:14px;\"\u003e\n    Use the free KOEED toolset to validate wiring, analog scaling, and serial CRC before commissioning.\n  \u003c\/p\u003e\n  \u003ca href=\"\/id\/pages\/plc-hex-float-converter\" style=\"color:#0056B3; text-decoration:underline; font-weight:bold; font-size:14px; font-family:Arial, Helvetica, sans-serif;\"\u003eOpen PLC Hex to Float Converter\u003c\/a\u003e\n   | \n  \u003ca href=\"\/id\/pages\/modbus-crc-calculator\" style=\"color:#0056B3; text-decoration:underline; font-weight:bold; font-size:14px; font-family:Arial, Helvetica, sans-serif;\"\u003eModbus CRC Calculator\u003c\/a\u003e\n   | \n  \u003ca href=\"\/id\/pages\/plc-analog-calculator\" style=\"color:#0056B3; text-decoration:underline; font-weight:bold; font-size:14px; font-family:Arial, Helvetica, sans-serif;\"\u003ePLC Analog Calculator\u003c\/a\u003e\n   | \n  \u003ca href=\"\/id\/pages\/ai-tool\" style=\"color:#0056B3; text-decoration:underline; font-weight:bold; font-size:14px; font-family:Arial, Helvetica, sans-serif;\"\u003eAI Diagnostic Tool\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- ============ Bottom: Contact \/ FAQ \/ Quote ============ --\u003e\n\u003cdiv style=\"border:1px solid #eeeeee; background-color:#fafafa; padding:16px 24px; margin:16px 0; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"font-family:Arial, Helvetica, sans-serif; margin:0 0 8px 0; color:#111111; font-size:14px; line-height:22px;\"\u003e\n    Need to talk to a sourcing engineer before sending the BOM? Use the \u003ca href=\"\/id\/pages\/contact-us\" style=\"color:#0056B3; text-decoration:underline;\"\u003eContact Us\u003c\/a\u003e page, the \u003ca href=\"\/id\/pages\/request-for-quote\" style=\"color:#0056B3; text-decoration:underline;\"\u003eCreate a Quote\u003c\/a\u003e form, or email \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20DKLD%20LDZ-6-4-18A%20127V%20Push%20Button\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e directly. Common engineering questions on the LDZ-6 family are answered on the \u003ca href=\"\/id\/pages\/faq\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFAQs\u003c\/a\u003e page.\n  \u003c\/p\u003e\n  \u003cp style=\"font-family:Arial, Helvetica, sans-serif; margin:0; color:#555555; font-size:13px; line-height:20px;\"\u003e\n    All quotes are binding only after written confirmation from \u003cstrong\u003eMoritta@KOEED.COM\u003c\/strong\u003e. Specifications on this page are read from the part-number code and standard IEC 60947-5-1 references; final datasheet values govern at the time of shipment.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n","brand":"KOEED","offers":[{"title":"Default Title","offer_id":44730849722553,"sku":"355232217620","price":27.54,"currency_code":"USD","in_stock":true}],"url":"https:\/\/koeed.com\/id\/products\/new-1pc-fit-dkld-ldz-6-4-18a-127v-5e4-ip55-t85-55-push-button-switch-6pins","provider":"KOEED","version":"1.0","type":"link"}