{"product_id":"new-facon-s07-motor-brake-rectifier-module-ac230v-480v-dc110-220v-t-0-3s","title":"FACON S07 Motor brake rectifier module AC230V\/480V DC110\/220V t=0.3s","description":"\u003c!-- FACON S07 Motor Brake Rectifier - Product Description --\u003e\n\u003cdiv class=\"koeed-container\"\u003e\n  \u003ch2\u003eFACON S07: Motor Brake Rectifier Module\u003c\/h2\u003e\n\n  \u003cp class=\"koeed-intro\"\u003eThe FACON S07 is a versatile motor brake rectifier module designed for industrial motor brake applications. Supporting AC 230V\/480V input with DC 110V\/220V output and 0.3s timing, this module provides reliable AC to DC conversion for electromagnetic brake systems.\u003c\/p\u003e\n\n  \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n  \u003cdiv style=\"overflow-x: auto;\"\u003e\n    \u003ctable class=\"koeed-specs-table\"\u003e\n      \u003cthead\u003e\n        \u003ctr\u003e\n          \u003cth\u003eParameter\u003c\/th\u003e\n          \u003cth\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eModel Number\u003c\/td\u003e\n          \u003ctd\u003eS07\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eBrand\u003c\/td\u003e\n          \u003ctd\u003eFACON\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eType\u003c\/td\u003e\n          \u003ctd\u003eMotor Brake Rectifier\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eInput Voltage\u003c\/td\u003e\n          \u003ctd\u003eAC 230V \/ 480V\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eOutput Voltage\u003c\/td\u003e\n          \u003ctd\u003eDC 110V \/ 220V\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eTiming\u003c\/td\u003e\n          \u003ctd\u003e0.3s\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eCurrent Rating\u003c\/td\u003e\n          \u003ctd\u003e2A\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eRectification\u003c\/td\u003e\n          \u003ctd\u003eHalf-Wave\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eCooling\u003c\/td\u003e\n          \u003ctd\u003eNatural Convection\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eMounting\u003c\/td\u003e\n          \u003ctd\u003ePanel Mount\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003ch3\u003eApplications\u003c\/h3\u003e\n  \u003cul class=\"koeed-applications\"\u003e\n    \u003cli\u003eIndustrial motor brakes\u003c\/li\u003e\n    \u003cli\u003eConveyor emergency stops\u003c\/li\u003e\n    \u003cli\u003eElevator safety brakes\u003c\/li\u003e\n    \u003cli\u003eCrane brakes\u003c\/li\u003e\n    \u003cli\u003eWinch safety systems\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul class=\"koeed-features\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDual Voltage:\u003c\/strong\u003e 230V\/480V AC input selectable\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTiming Function:\u003c\/strong\u003e 0.3s delay for controlled release\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVersatile Application:\u003c\/strong\u003e Compatible with most brake types\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePanel Mount:\u003c\/strong\u003e Easy installation\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFACON Quality:\u003c\/strong\u003e Reliable industrial design\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n  \u003col class=\"koeed-installation\"\u003e\n    \u003cli\u003eSelect correct input voltage for system\u003c\/li\u003e\n    \u003cli\u003eMount on ventilated panel\u003c\/li\u003e\n    \u003cli\u003eConnect AC input to power source\u003c\/li\u003e\n    \u003cli\u003eConnect DC output to brake coil\u003c\/li\u003e\n    \u003cli\u003eSet timing if applicable\u003c\/li\u003e\n  \u003c\/ol\u003e\n\n  \u003cnoscript\u003e\n    \u003cp\u003eThe FACON S07 is a motor brake rectifier module. Input: 230V\/480V AC, Output: 110V\/220V DC. 0.3s timing function. Half-wave rectification. For industrial motor brake applications.\u003c\/p\u003e\n  \u003c\/noscript\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the 0.3s timing function for?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The 0.3s timing provides a delay before brake release, ensuring proper sequence with other equipment. Prevents premature release before drive is ready.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can I use 480V input for a 230V brake?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No, always match input voltage to system supply. Using 480V on a 230V system will damage the brake. Check the motor nameplate for correct voltage.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"FACON","offers":[{"title":"Default Title","offer_id":44572910583993,"sku":"234303049329","price":43.29,"currency_code":"USD","in_stock":true}],"url":"https:\/\/koeed.com\/id\/products\/new-facon-s07-motor-brake-rectifier-module-ac230v-480v-dc110-220v-t-0-3s","provider":"KOEED","version":"1.0","type":"link"}