{"product_id":"new-gp-d60sh-12-dc12v-0-18a-6025-3-wire-silent-cooling-fan","title":"new GP D60SH-12 DC12V 0.18A 6025 3-Wire Silent Cooling Fan","description":"\u003ch1 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:28px; line-height:36px; margin:0 0 8px 0;\"\u003e\n  GP D60SH-12 6025 Cooling Fan — 60×60×25mm, 12V DC, 0.18A, 3-Wire Silent Axial Fan\n\u003c\/h1\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#0056B3; font-size:14px; line-height:22px; letter-spacing:1px; text-transform:uppercase; margin:0 0 24px 0;\"\u003e\n  GP · 6025 Form Factor · 12V DC · Tachometer Output · In Stock\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:0 0 16px 0;\"\u003e\n  The \u003cstrong\u003eGP D60SH-12\u003c\/strong\u003e is a 60×60×25mm (commonly referenced as \u003cstrong\u003e6025\u003c\/strong\u003e) axial DC cooling fan drawing 0.18A at 12V, with a 3-wire interface providing V+, GND, and a tachometer (RPM) feedback signal. GP is a third-party OEM label widely used in replacement-fan catalogs for industrial enclosures, embedded controllers, and small automation cells. At roughly 2.16W of draw, the D60SH-12 sits squarely in the “light-duty” cooling class, where it is matched against the heat-load of a single control board, an HMI backlight, or a stepper driver heatsink rather than a full power-supply bay. For a complete view of KOEED’s industrial automation lineup, see our\n  \u003ca href=\"\/id\/collections\" style=\"color:#0056B3; text-decoration:underline;\"\u003ecomplete product catalog\u003c\/a\u003e\n  or browse the\n  \u003ca href=\"\/id\/pages\/brands\" style=\"color:#0056B3; text-decoration:underline;\"\u003ebrand index\u003c\/a\u003e.\n\u003c\/p\u003e\n\n\u003c!-- ============ Section 1: Key Technical Specifications ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  1. Key Technical Specifications \u0026amp; Overview\n\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #eeeeee; font-family:Arial, Helvetica, sans-serif; font-size:14px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eGP (third-party OEM, no factory-authorization claimed)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003ePart Number\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eD60SH-12\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eForm Factor\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e6025 — 60 × 60 × 25 mm axial fan\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eOperating Voltage\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e12V DC (typical operating range 7–13.8V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eRated Current\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e0.18A (nominal) · Approx. 2.16W power draw\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eWire Count \u0026amp; Function\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e3-wire — V+ (red), GND (black), Tach \/ RPM signal (yellow)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eBearing Type\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eSleeve or ball bearing (varies by sub-lot — confirm before ordering)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eNoise Level\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eLow-dBA, marketed as “silent” at 12V nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eAirflow Class\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eLight-duty (single heatsink \/ local cabinet cooling)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eConnector\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eTinned lead wires, 3-pin mating available on request\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e-10°C to +70°C (storage -20°C to +75°C)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eStock Status\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        In stock — quote within 24 hours at \u003ca href=\"mailto:Moritta@KOEED.COM\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:16px 0 0 0;\"\u003e\n  Because the 6025 footprint is shared by dozens of OEM labels (Nidec, Sunon, Delta, AVC, Foxconn), the D60SH-12 is most often sourced as a \u003cem\u003eform-fit-function\u003c\/em\u003e replacement — the bezel pattern, screw spacing, and connector pinout must be matched against the host board, not the fan label. Engineers cross-checking against existing\n  \u003ca href=\"\/id\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e,\n  \u003ca href=\"\/id\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e, or\n  \u003ca href=\"\/id\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e\n  spares lists should compare current draw and tach output, not just dimensions.\n\u003c\/p\u003e\n\n\u003c!-- ============ Section 2: Application Scenarios ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  2. Application Scenarios — Where It Fits\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003e\n  The GP D60SH-12 6025 fan is a general-purpose axial flow unit intended for sealed enclosures with modest heat dissipation needs. In the industrial-automation context it shows up most often as a replacement part for the following hosts:\n\u003c\/p\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSmall PLC racks and remote I\/O blocks\u003c\/strong\u003e — secondary cooling where a single\n    \u003ca href=\"\/id\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e CP1E or\n    \u003ca href=\"\/id\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e Modicon M340 backplane is sealed inside a wall-mount cabinet.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHMI touch panels and operator stations\u003c\/strong\u003e — exhaust-side fan on the back of a 7–10 inch panel, helping the LCD backlight inverter and CPU board stay within spec.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact inverters and servo amplifiers\u003c\/strong\u003e — the 6025 form is common on the heatsink shroud of low-kW drives from\n    \u003ca href=\"\/id\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e Sigma and\n    \u003ca href=\"\/id\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic\u003c\/a\u003e Minas lines.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial PCs and edge gateways\u003c\/strong\u003e — top or side exhaust on small fanless-converted-to-fanless-with-fan IPCs that ship with a 60mm cut-out.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCNC machine auxiliary bays\u003c\/strong\u003e — in\n    \u003ca href=\"\/id\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e 0i \/ 30i enclosures where the spindle cabinet is sealed and a single radial intake is not enough.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3D-printer and motion-control stepper driver cooling\u003c\/strong\u003e — direct-mount heatsink fan for closed-loop drivers, where 0.18A at 12V matches the printer’s PSU rail.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVision inspection enclosures\u003c\/strong\u003e — the\n    \u003ca href=\"\/id\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e CV \/ XG camera head enclosures that need a low-vibration, low-dBA axial fan.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow-power server rooms and network racks\u003c\/strong\u003e — top-of-rack exhaust fan on 1U \/ 2U appliances where a 40mm fan cannot move enough air.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  Use the KOEED\n  \u003ca href=\"\/id\/pages\/plc-error-code-lookup\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePLC Error Code Database\u003c\/a\u003e\n  if the host system is logging a thermal-fan alarm — the fault is often a failed 6025, not a CPU fault.\n\u003c\/p\u003e\n\n\u003c!-- ============ Section 3: Integration \u0026 Wiring Notes ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  3. Integration \u0026amp; Wiring Notes\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003e\n  The 3-wire variant of the D60SH-12 follows the de-facto industry convention used across\n  \u003ca href=\"\/id\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e and\n  \u003ca href=\"\/id\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e panel PCs:\n\u003c\/p\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRed wire — V+ (12V DC)\u003c\/strong\u003e. Tie to a fused 12V rail. Most 6025 fans accept 7–13.8V, so the same wire can run from a 12V lead-acid backup rail.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlack wire — GND\u003c\/strong\u003e. Star-ground back to the cabinet chassis ground bar; do not daisy-chain across multiple fans if the run is more than 200mm.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eYellow wire — Tachometer (open-collector, pulses per revolution, typically 2 ppr)\u003c\/strong\u003e. Pull up to logic level (often 3.3V or 5V) through a 10kΩ resistor at the PLC \/ MCU end. A stalled fan pulls the line low continuously, which is what supervisory firmware (e.g. on\n    \u003ca href=\"\/id\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e MELSEC or\n    \u003ca href=\"\/id\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e SYSMAC CPUs) interprets as a fan-fault.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  The D60SH-12 does \u003cem\u003enot\u003c\/em\u003e include a PWM control input. If your host platform (a\n  \u003ca href=\"\/id\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e Magelis HMI, for example) expects a 4-wire PWM fan, the tach output is still usable for monitoring, but speed regulation has to be done by an external FET on the V+ line.\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  For cabinets that already host\n  \u003ca href=\"\/id\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e servo amplifiers or\n  \u003ca href=\"\/id\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e Sigma drives, observe the manufacturer’s 100mm minimum clearance around the air intake; the 6025 form factor has a relatively short 25mm depth and benefits from a straight, unobstructed path.\n\u003c\/p\u003e\n\n\u003c!-- ============ Section 4: Installation \u0026 Commissioning Tips ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  4. Installation \u0026amp; Commissioning Tips\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003e\n  A 6025 fan swap is a five-minute job on most modern enclosures, but a few habits extend service life significantly:\n\u003c\/p\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMatch airflow direction.\u003c\/strong\u003e The label side typically faces the air intake. Reversing the fan in a\n    \u003ca href=\"\/id\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e vision enclosure can push warm air back across the camera sensor instead of exhausting it.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUse the original anti-vibration grommets.\u003c\/strong\u003e The D60SH-12’s sleeve-bearing variant can transmit 50Hz hum into thin-gauge steel panels; the four corner grommets damp this.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfirm rotation at first power-up.\u003c\/strong\u003e Listen for a 1-second ramp, then steady-state. A stalled fan that draws 0.18A without spinning will heat up its windings within minutes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTie the tach wire to a known input.\u003c\/strong\u003e Verify with the\n    \u003ca href=\"\/id\/pages\/plc-analog-calculator\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePLC Analog Calculator\u003c\/a\u003e\n    or the\n    \u003ca href=\"\/id\/pages\/modbus-crc-calculator\" style=\"color:#0056B3; text-decoration:underline;\"\u003eModbus CRC Calculator\u003c\/a\u003e\n    tool when you bring the panel back online — many control vendors require a sanity check of the supervisory register before the cabinet is signed off.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAvoid stacking heat sources.\u003c\/strong\u003e Two 6025 fans mounted 10mm apart on the same heatsink will starve each other; offset them or use a single larger 80×80×25 unit.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDocument the bearing type.\u003c\/strong\u003e Sleeve bearings are quieter but rated for ~20,000 hours; ball-bearing variants are louder but last \u0026gt;40,000 hours. Note which your cabinet was built with so the next replacement matches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  For diagnostic support on a stubborn thermal alarm, the KOEED\n  \u003ca href=\"\/id\/pages\/ai-tool\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAI Diagnostic Tool\u003c\/a\u003e\n  accepts a photo of the host panel nameplate and will suggest candidate replacement fans including the D60SH-12 line.\n\u003c\/p\u003e\n\n\u003c!-- ============ Section 5: Procurement, Warranty \u0026 Lead Time ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  5. Procurement, Warranty \u0026amp; Lead Time\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003e\n  The GP D60SH-12 is a catalog stock item at KOEED and is typically shipped from the Shenzhen \/ Hong Kong dual base within the same business week. Quotation is by email — we do not publish fixed unit prices online because fan pricing moves with copper, magnet, and bearing-component markets. To get a binding quote, send a one-line email to\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20GP%20D60SH-12%206025\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e\n  with your required quantity and target delivery country, or use the\n  \u003ca href=\"\/id\/pages\/request-for-quote\" style=\"color:#0056B3; text-decoration:underline;\"\u003eCreate a Quote\u003c\/a\u003e\n  form to add the part to a larger BOM.\n\u003c\/p\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLead time\u003c\/strong\u003e — 1–3 business days for in-stock units; 2–3 weeks for bulk orders \u0026gt;1,000pcs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum order\u003c\/strong\u003e — one unit; volume discounts available on request.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e — KOEED supplies only tested, working units. Fans with sleeve bearings carry the OEM-rated service-life caveat; please specify ball-bearing variants for 24\/7 installations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWorldwide shipping\u003c\/strong\u003e — DHL \/ FedEx \/ UPS standard; bulk orders can be palletized for sea freight.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDocumentation\u003c\/strong\u003e — commercial invoice, packing list, and Certificate of Origin supplied with every shipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  Engineers maintaining spare-parts kits for multi-vendor plants (covering\n  \u003ca href=\"\/id\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e,\n  \u003ca href=\"\/id\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e,\n  \u003ca href=\"\/id\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e,\n  \u003ca href=\"\/id\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e,\n  \u003ca href=\"\/id\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e,\n  \u003ca href=\"\/id\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e,\n  \u003ca href=\"\/id\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e,\n  \u003ca href=\"\/id\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic\u003c\/a\u003e, and\n  \u003ca href=\"\/id\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e\n  equipment on the same shop floor) usually keep a small stock of 6025 fans on the shelf — the D60SH-12 covers the majority of those form-fit cases. For full-BOM requests covering fans, drives, PLCs, and HMIs, send the instrument list to\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20GP%20D60SH-12%206025\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e\n  and we will reply with availability and price within 24 hours. Additional resources for selecting the right replacement fan include the\n  \u003ca href=\"\/id\/pages\/plc-error-code-lookup\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePLC Error Code Database\u003c\/a\u003e,\n  our\n  \u003ca href=\"\/id\/pages\/faq\" style=\"color:#0056B3; text-decoration:underline;\"\u003eengineering FAQ\u003c\/a\u003e, and the\n  \u003ca href=\"\/id\/pages\/about-us\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAbout KOEED\u003c\/a\u003e page. For the latest KOEED engineering notes and supply updates, see the\n  \u003ca href=\"\/id\/blogs\/%E6%96%B0%E9%97%BB\" style=\"color:#0056B3; text-decoration:underline;\"\u003elatest KOEED blog\u003c\/a\u003e\n  or return to the\n  \u003ca href=\"\/id\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKOEED homepage\u003c\/a\u003e.\n\u003c\/p\u003e\n\n\u003c!-- ============ Primary CTA ============ --\u003e\n\u003cdiv style=\"background-color:#16c8c8; padding:24px 32px; margin:32px 0; text-align:center; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003ch3 style=\"margin:0 0 12px 0; color:#ffffff; font-size:20px; line-height:28px;\"\u003e\n    Need GP D60SH-12 fans or a full panel BOM?\n  \u003c\/h3\u003e\n  \u003cp style=\"margin:0 0 16px 0; color:#ffffff; font-size:15px; line-height:22px;\"\u003e\n    Send your part list to \u003cstrong\u003eMoritta@KOEED.COM\u003c\/strong\u003e and get availability \u0026amp; price within 24 hours.\n  \u003c\/p\u003e\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20GP%20D60SH-12%206025\" style=\"display:inline-block; background-color:#ffffff; color:#0056B3; padding:12px 24px; text-decoration:none; font-weight:bold; border-radius:4px; font-size:15px;\"\u003e\n    Request a Quote →\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- ============ Secondary CTA ============ --\u003e\n\u003cdiv style=\"border:1px solid #0056B3; padding:16px 24px; margin:16px 0; text-align:left; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 8px 0; color:#111111; font-size:15px; line-height:22px;\"\u003e\n    Looking for more industrial-automation spares — PLCs, drives, HMIs, CNC parts?\n  \u003c\/p\u003e\n  \u003ca href=\"\/id\/collections\" style=\"display:inline-block; color:#0056B3; padding:6px 18px; text-decoration:none; font-weight:bold; border:1px solid #0056B3; border-radius:4px; font-size:14px;\"\u003e\n    Browse All Collections →\n  \u003c\/a\u003e\n   \n  \u003ca href=\"\/id\/pages\/contact-us\" style=\"display:inline-block; color:#0056B3; padding:6px 18px; text-decoration:none; font-weight:bold; border:1px solid #0056B3; border-radius:4px; font-size:14px;\"\u003e\n    Contact KOEED →\n  \u003c\/a\u003e\n\u003c\/div\u003e\n","brand":"GP","offers":[{"title":"Default Title","offer_id":44746663100601,"sku":"155933452967","price":30.48,"currency_code":"USD","in_stock":true}],"url":"https:\/\/koeed.com\/id\/products\/new-gp-d60sh-12-dc12v-0-18a-6025-3-wire-silent-cooling-fan","provider":"KOEED","version":"1.0","type":"link"}