{"product_id":"1pcs-new-for-181464g1r6-416741g2r10-dual-port-temperature-and-humidity-sensor","title":"Dual Port Temperature and Humidity Sensor 181464G1R6 416741G2R10","description":"\u003cdiv class=\"product-description-container\" style=\"font-family: 'Segoe UI', Arial, sans-serif; line-height: 1.6; color: #333;\"\u003e\n\n    \u003cp\u003eThe \u003cstrong\u003e181464G1R6 \/ 416741G2R10\u003c\/strong\u003e is a high-precision \u003cstrong\u003edual port temperature and humidity sensor\u003c\/strong\u003e engineered for strict environmental monitoring in industrial facilities, data centers, and cleanrooms. Featuring dual sensing ports for redundant or multi-zone tracking, this unit delivers highly stable analog signals to Building Management Systems (BMS) and PLCs. Whether you are sourcing an \u003cstrong\u003e181464G1R6 replacement\u003c\/strong\u003e for a critical HVAC system or looking for a robust \u003cstrong\u003eequivalent to specialized climate control sensors\u003c\/strong\u003e, this component ensures long-term accuracy with minimal measurement drift.\u003c\/p\u003e\n\n    \u003chr style=\"border: 0; height: 1px; background: #eee; margin: 20px 0;\"\u003e\n\n    \u003ch3 style=\"color: #005aa3; border-left: 4px solid #005aa3; padding-left: 12px; margin-top: 25px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto;\"\u003e\n        \u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 15px; border: 1px solid #e1e1e1;\"\u003e\n            \u003cthead\u003e\n                \u003ctr style=\"background-color: #f4f7f9;\"\u003e\n                    \u003cth style=\"padding: 12px; border: 1px solid #e1e1e1; text-align: left;\"\u003eParameter\u003c\/th\u003e\n                    \u003cth style=\"padding: 12px; border: 1px solid #e1e1e1; text-align: left;\"\u003eDetails\u003c\/th\u003e\n                \u003c\/tr\u003e\n            \u003c\/thead\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1; font-weight: bold;\"\u003ePart Numbers\u003c\/td\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1;\"\u003e181464G1R6 \/ 416741G2R10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #fafafa;\"\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1; font-weight: bold;\"\u003eSensor Type\u003c\/td\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1;\"\u003eDual Port Temperature \u0026amp; Relative Humidity (RH)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1; font-weight: bold;\"\u003eRelative Humidity Range\u003c\/td\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1;\"\u003e0 to 100% RH (Non-condensing)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #fafafa;\"\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1; font-weight: bold;\"\u003eTemperature Range\u003c\/td\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1;\"\u003eStandard Industrial Range (e.g., -20°C to +80°C)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1; font-weight: bold;\"\u003eOutput Signal\u003c\/td\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1;\"\u003eStandard Analog (Typically 4-20mA or 0-10V DC)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #fafafa;\"\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1; font-weight: bold;\"\u003eHousing \/ Protection\u003c\/td\u003e\n                    \u003ctd style=\"padding: 10px; border: 1px solid #e1e1e1;\"\u003eDust and Moisture Resistant Enclosure\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\n    \u003ch3 style=\"color: #005aa3; border-left: 4px solid #005aa3; padding-left: 12px; margin-top: 30px;\"\u003eIndustrial Environmental Control\u003c\/h3\u003e\n    \u003cp\u003eThe \u003cstrong\u003edual port sensor configuration\u003c\/strong\u003e is widely utilized in sophisticated air handling units (AHUs) and industrial incubators, allowing for differential measurements or primary\/backup redundancy without installing separate devices. Its advanced capacitive polymer RH element provides rapid response times to sudden microclimate shifts. As a durable \u003cstrong\u003eindustrial climate control part\u003c\/strong\u003e, it resists contamination from chemical vapors and particulate matter, serving as a dependable \u003cstrong\u003erepair part\u003c\/strong\u003e for maintaining strict environmental compliance in semiconductor manufacturing and pharmaceutical storage.\u003c\/p\u003e\n\n    \u003ch3 style=\"color: #005aa3; border-left: 4px solid #005aa3; padding-left: 12px; margin-top: 30px;\"\u003e181464G1R6 \/ 416741G2R10 Troubleshooting FAQ\u003c\/h3\u003e\n    \u003cul style=\"padding-left: 20px;\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eHumidity reading stuck at maximum (e.g., 100% or 20mA)?\u003c\/strong\u003e This typically indicates condensation has formed directly on the sensing element, or the sintered filter cap is saturated with moisture. Allow the \u003cstrong\u003e181464G1R6 sensor\u003c\/strong\u003e to dry in a clean environment. If the reading does not recover, the capacitive element is permanently damaged.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eController displays \"Sensor Error\" or no signal?\u003c\/strong\u003e Verify the DC loop power supply to the transmitter. Check the \u003cstrong\u003e416741G2R10 wiring diagram\u003c\/strong\u003e to ensure the polarity is correct for the analog outputs, and inspect the terminal block for corrosion caused by high-humidity exposure.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eTemperature\/Humidity readings are drifting?\u003c\/strong\u003e Airborne chemicals or heavy dust can coat the sensor over time, causing a shift in calibration. Refer to the \u003cstrong\u003e181464G1R6 manual PDF\u003c\/strong\u003e for instructions on carefully cleaning or replacing the protective filter mesh without touching the delicate internal microchip.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"KOEED","offers":[{"title":"Default Title","offer_id":43949766377657,"sku":"305222204132","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0268\/8476\/7929\/files\/s-l1600_03020053-687e-473c-b6fc-5a87c90606b9.jpg?v=1713151828","url":"https:\/\/koeed.com\/it\/products\/1pcs-new-for-181464g1r6-416741g2r10-dual-port-temperature-and-humidity-sensor","provider":"KOEED","version":"1.0","type":"link"}