{"product_id":"1pcs-new-rexroth-sensor-giv50-11-r900174537-r901465833-valve-position-switch","title":"REWROTH GIV50-11 R900174537 Valve Position Switch Sensor","description":"\u003ch1 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:28px; line-height:36px; margin:0 0 8px 0;\"\u003e\n  Rexroth GIV50-11 \/ R900174537 \/ R901465833 — Valve Position Switch Sensor\n\u003c\/h1\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#0056B3; font-size:14px; line-height:22px;\n          letter-spacing:1px; text-transform:uppercase; margin:0 0 24px 0;\"\u003e\n  Bosch Rexroth · GIV Series · Hydraulic Valve Position Monitor · In stock · Worldwide Shipping\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:0 0 16px 0;\"\u003e\n  The \u003cstrong\u003eRexroth GIV50-11\u003c\/strong\u003e is an inductive valve position switch and monitor from Bosch Rexroth,\n  designed to detect the spool position of 4\/3 and 4\/2 hydraulic directional control valves in real time.\n  The two catalog material numbers\n  \u003ca href=\"\/it\/products\/rexroth-giv50-11-r900174537\" style=\"color:#0056B3; text-decoration:underline;\"\u003eR900174537\u003c\/a\u003e\n  and \u003ca href=\"\/it\/products\/rexroth-giv50-11-r901465833\" style=\"color:#0056B3; text-decoration:underline;\"\u003eR901465833\u003c\/a\u003e\n  cover the standard and the extended temperature variants of the same GIV50-11 form factor.\n  KOEED sources genuine Rexroth hydraulic feedback sensors for legacy repair, line retrofits and\n  \u003ca href=\"\/it\/collections\" style=\"color:#0056B3; text-decoration:underline;\"\u003efactory automation\u003c\/a\u003e\n  projects, sitting alongside the core\n  \u003ca href=\"\/it\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e,\n  \u003ca href=\"\/it\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e,\n  \u003ca href=\"\/it\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e,\n  \u003ca href=\"\/it\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e,\n  \u003ca href=\"\/it\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e,\n  \u003ca href=\"\/it\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e,\n  \u003ca href=\"\/it\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e,\n  \u003ca href=\"\/it\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic\u003c\/a\u003e\n  and \u003ca href=\"\/it\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e\n  PLC, servo and CNC lines.\n  Send your BOM to\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Rexroth%20GIV50-11%20Valve%20Position%20Switch\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e\n  and we will reply with availability and lead time within 24 hours.\n\u003c\/p\u003e\n\n\u003c!-- ============ H2 #1: Key Technical Specifications ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Key Technical Specifications\n\u003c\/h2\u003e\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  The GIV50-11 sits inside Rexroth's GIV family of contactless position-feedback devices for hydraulic valves.\n  It outputs a binary signal as soon as the valve spool reaches its commanded end position, which makes it a\n  true closed-loop position indicator rather than a simple mechanical limit switch. The table below is the\n  engineering snapshot most often requested by maintenance engineers and system integrators.\n\u003c\/p\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #eeeeee;\n              font-family:Arial, Helvetica, sans-serif; font-size:14px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003eBosch Rexroth (Germany)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003eGIV — Inductive valve position switch \/ monitor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eMaterial Number — R900174537\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003eStandard temperature variant of GIV50-11\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eMaterial Number — R901465833\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003eExtended temperature \/ variant designation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eFunction\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003eContactless detection of directional-valve spool position (4\/3 or 4\/2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSensing Principle\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003eInductive (NAMUR \/ IEC 60947 compliant) — no mechanical contact with the spool\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eOutput Signal\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003eTwo binary position signals (one per spool end position)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eConnector\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003eM12 connector, 4-pin (industry standard for proximity \/ valve feedback)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSupply Voltage\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003e24 V DC nominal (NAMUR intrinsically-safe interface)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003e-25 °C to +85 °C (R901465833 rated up to +100 °C)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eIngress Protection\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003eIP67 (dust-tight, protected against temporary immersion)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eCompatible Valves\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003eRexroth 4\/3 and 4\/2 directional control valves with GIV mounting interface\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eMounting\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003eDirect-mount on valve body via integrated clamp — no external bracket required\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003eGermany\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eStock Status\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px;\n                 border:1px solid #eeeeee; color:#333333;\"\u003e\n        In stock — quote within 24 hours at\n        \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Rexroth%20GIV50-11%20Valve%20Position%20Switch\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c!-- ============ H2 #2: Application Scenarios ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Application Scenarios \u0026amp; Where It Fits\n\u003c\/h2\u003e\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  The GIV50-11 is a position-feedback device, not a controller. Its job is to tell the upstream PLC —\n  whether that is a \u003ca href=\"\/it\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e\n  SIMATIC, an \u003ca href=\"\/it\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e\n  ControlLogix or a \u003ca href=\"\/it\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e\n  MELSEC — that the hydraulic valve has actually reached the commanded position before the next machine\n  motion is allowed. Without that feedback the PLC would be commanding motion blind, which is unacceptable in\n  any safety-relevant cell. Typical deployments:\n\u003c\/p\u003e\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInjection molding machines\u003c\/strong\u003e — confirms clamp and ejector valve position before mold-close or mold-open transitions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDie casting and forging presses\u003c\/strong\u003e — interlock for high-tonnage presses, with the GIV50-11 wired into the press safety chain.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMachine tools and CNC hydraulics\u003c\/strong\u003e — turret, tailstock and chuck position confirmation paired with\n    \u003ca href=\"\/it\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e and\n    \u003ca href=\"\/it\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e servo axes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMarine and offshore hydraulics\u003c\/strong\u003e — deck machinery, winch control valves and bow-thruster actuators.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMobile hydraulics and heavy equipment\u003c\/strong\u003e — loaders, excavators and harvesters where a contactless sensor survives vibration better than a mechanical limit switch.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSteel, paper and process plants\u003c\/strong\u003e — hydraulic roll positioning, tension control and shear actuation, typically integrated with\n    \u003ca href=\"\/it\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e Modicon or\n    \u003ca href=\"\/it\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e SYSMAC PLCs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePress shop and body-in-white\u003c\/strong\u003e — end-of-stroke verification on forming and welding cells, often alongside\n    \u003ca href=\"\/it\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e vision inspection\n    and \u003ca href=\"\/it\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic\u003c\/a\u003e FP PLCs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c!-- ============ H2 #3: Integration \u0026 Wiring Notes ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Integration \u0026amp; Wiring Notes\n\u003c\/h2\u003e\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  The GIV50-11 uses a four-pin M12 connector, which is the de-facto standard for NAMUR-style valve feedback\n  in European hydraulic cabinets. Pin-out, supply polarity and shielding should be cross-checked against the\n  wiring diagram in the Rexroth data sheet before commissioning — the sensor is polarity-sensitive.\n  Common integration points engineers ask about:\n\u003c\/p\u003e\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePin 1 (+UB) and Pin 3 (0 V):\u003c\/strong\u003e 24 V DC supply, typically drawn from the same power distribution that feeds the PLC digital input card. Add a dedicated 24 V branch if the cabinet shares a noisy bus.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePin 4 (output A) and Pin 2 (output B):\u003c\/strong\u003e one output per spool end-position. Wire each to a dedicated PLC fast input when the GIV is part of a safety chain.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable routing:\u003c\/strong\u003e keep the M12 lead at least 100 mm away from variable-frequency drive power cables (Schneider Altivar, Yaskawa Varispeed, Allen-Bradley PowerFlex) to avoid coupling noise into the inductive sense element.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e if the M12 cable is shielded, ground the shield at the cabinet end only — do not loop the shield to ground at the valve end as well, otherwise ground loops will inject false triggers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePLC interface card:\u003c\/strong\u003e any standard 24 V sinking digital input works. For NAMUR intrinsic safety or long cable runs, use a dedicated NAMUR input module or a barrier from the\n    \u003ca href=\"\/it\/pages\/plc-error-code-lookup\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePLC error code lookup\u003c\/a\u003e reference list.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDiagnostic feedback:\u003c\/strong\u003e a healthy GIV50-11 shows a clean on\/off transition when the spool is commanded. A chattering or sticky output is almost always a wiring or supply issue, not a sensor failure — check the 24 V rail before replacing the unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c!-- ============ H2 #4: Installation \u0026 Commissioning Tips ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Installation \u0026amp; Commissioning Tips\n\u003c\/h2\u003e\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  The GIV50-11 is a fit-and-forget device when mounted correctly. The most common field failures we see on\n  incoming warranty units are mechanical, not electrical: the sensor has been torqued out of spec, or the\n  M12 has been hand-crimped without proper strain relief. A clean install looks like this:\n\u003c\/p\u003e\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVerify the form factor first.\u003c\/strong\u003e The GIV50-11 mounts only on Rexroth valves with the matching GIV50 mechanical interface. Use the manufacturer's selection tool if you are retrofitting a non-Rexroth valve — the sensor expects a specific spool stroke window to detect position reliably.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque the clamp to spec.\u003c\/strong\u003e Over-tightening distorts the housing and shifts the inductive sense element out of alignment. Use a torque wrench and follow the Rexroth data sheet value (typically a modest single-digit N·m figure).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHand-tighten the M12 connector.\u003c\/strong\u003e Do not use pliers or channel-locks on the M12 coupling nut — a quarter-turn past hand-tight is the correct seating torque. A crushed coupling nut is the second most common field failure we see.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower up and observe both outputs.\u003c\/strong\u003e With 24 V applied, the GIV50-11 will show a steady state per spool position. Manually command the valve from the PLC and watch each output toggle cleanly.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVerify the safety chain end-to-end.\u003c\/strong\u003e If the GIV is wired into a press safety circuit, do not trust the green light alone — force a fault condition (e.g. disconnect the M12) and confirm that the upstream PLC actually drops out within its rated response time.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLog commissioning data.\u003c\/strong\u003e Stamp the install date on the sensor body with a permanent marker and record the part number, material number and valve serial in your CMMS. This makes future\n    \u003ca href=\"\/it\/pages\/ai-tool\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAI-assisted diagnostics\u003c\/a\u003e\n    and cross-referencing much faster.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c!-- ============ H2 #5: Procurement, Warranty \u0026 Lead Time ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Procurement, Warranty \u0026amp; Lead Time\n\u003c\/h2\u003e\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  R900174537 and R901465833 are ordered through Rexroth's normal channel rather than picked off the shelf\n  of a generic electronics distributor, which is why so many maintenance teams end up waiting weeks when\n  they go direct. KOEED's\n  \u003ca href=\"\/it\/pages\/about-china-sourcing-company\" style=\"color:#0056B3; text-decoration:underline;\"\u003eChina sourcing\u003c\/a\u003e\n  team keeps both catalog numbers on the shelf for fast ship-out, alongside the rest of the GIV family.\n  A typical procurement cycle:\n\u003c\/p\u003e\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRFQ turnaround:\u003c\/strong\u003e 24 hours on business days. Send the material number, quantity and target ship-to country to\n    \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Rexroth%20GIV50-11%20Valve%20Position%20Switch\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e\n    and we will come back with availability, lead time and freight options.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLead time:\u003c\/strong\u003e in-stock units ship within 1–3 business days via DHL, FedEx or UPS. Out-of-stock or large-volume orders are quoted on a per-case basis against the live supplier lead time.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFull BOM quotations:\u003c\/strong\u003e if you are also replacing the upstream PLC, the HMI, the servo drive or any of the related valve accessories, send the entire instruments list. We will quote the lot in one pass — including\n    \u003ca href=\"\/it\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e,\n    \u003ca href=\"\/it\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e,\n    \u003ca href=\"\/it\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e,\n    \u003ca href=\"\/it\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e,\n    \u003ca href=\"\/it\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e,\n    \u003ca href=\"\/it\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e,\n    \u003ca href=\"\/it\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e,\n    \u003ca href=\"\/it\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic\u003c\/a\u003e\n    and \u003ca href=\"\/it\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e parts\n    when they appear on the same BOM.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month limited warranty against manufacturing defect. Sensors damaged by fluid ingress, mechanical impact, mis-wiring or operation outside the published electrical envelope are not covered — install per the data sheet and you are covered.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWorldwide shipping:\u003c\/strong\u003e DHL, FedEx, UPS and standard air freight. We do not publish fixed prices on the web — every quote is built around your actual ship-to country, quantity and desired Incoterm. Request a quote via\n    \u003ca href=\"\/it\/pages\/request-for-quote\" style=\"color:#0056B3; text-decoration:underline;\"\u003eCreate a Quote\u003c\/a\u003e\n    or by emailing the BOM to our RFQ inbox.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c!-- ============ Primary CTA ============ --\u003e\n\u003cdiv style=\"background-color:#16c8c8; padding:24px 32px; margin:32px 0; text-align:center;\n            font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003ch3 style=\"margin:0 0 12px 0; color:#ffffff; font-size:20px; line-height:28px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Need an R900174537 \/ R901465833 on the production line this week?\n  \u003c\/h3\u003e\n  \u003cp style=\"margin:0 0 16px 0; color:#ffffff; font-size:15px; line-height:22px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Send the part number, quantity and ship-to country to our RFQ inbox —\n    availability and freight within 24 hours.\n  \u003c\/p\u003e\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Rexroth%20GIV50-11%20Valve%20Position%20Switch\" style=\"display:inline-block; background-color:#ffffff; color:#0056B3; padding:12px 24px;\n            text-decoration:none; font-weight:bold; border-radius:4px; font-size:15px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Request a Quote →\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- ============ Secondary CTA ============ --\u003e\n\u003cdiv style=\"border:1px solid #0056B3; padding:16px 24px; margin:16px 0; text-align:left;\n            font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 8px 0; color:#111111; font-size:15px; line-height:22px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Looking for more Rexroth hydraulic sensors or full GIV-family coverage?\n  \u003c\/p\u003e\n  \u003ca href=\"\/it\/collections\" style=\"display:inline-block; color:#0056B3; padding:6px 18px;\n            text-decoration:none; font-weight:bold; border:1px solid #0056B3;\n            border-radius:4px; font-size:14px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Browse All Collections →\n  \u003c\/a\u003e\n  \u003ca href=\"\/it\/pages\/brands\" style=\"display:inline-block; color:#0056B3; padding:6px 18px;\n            text-decoration:none; font-weight:bold; border:1px solid #0056B3;\n            border-radius:4px; font-size:14px; font-family:Arial, Helvetica, sans-serif; margin-left:8px;\"\u003e\n    Browse Brands →\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- ============ Tertiary CTA: Engineering Tools ============ --\u003e\n\u003cdiv style=\"border:1px solid #eeeeee; background-color:#f4fcfc; padding:16px 24px; margin:16px 0;\n            font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 4px 0; color:#111111; font-size:15px; font-weight:bold; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    \u0026gt; Need to track down a Bosch Rexroth material number or decode a PLC fault?\n  \u003c\/p\u003e\n  \u003cp style=\"margin:0 0 8px 0; color:#333333; font-size:14px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Try the KOEED free online toolset and the 24\/7 AI diagnostic assistant.\n  \u003c\/p\u003e\n  \u003ca href=\"\/it\/pages\/plc-error-code-lookup\" style=\"color:#0056B3; text-decoration:underline; font-weight:bold; font-size:14px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Open PLC Error Code Lookup\n  \u003c\/a\u003e\n   · \n  \u003ca href=\"\/it\/pages\/ai-tool\" style=\"color:#0056B3; text-decoration:underline; font-weight:bold; font-size:14px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Open AI Diagnostic Tool\n  \u003c\/a\u003e\n   · \n  \u003ca href=\"\/it\/pages\/real-time-sales-list\" style=\"color:#0056B3; text-decoration:underline; font-weight:bold; font-size:14px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    View Real-Time Sales List\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- ============ Footer Strip ============ --\u003e\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#555555; font-size:13px; line-height:20px; margin:24px 0 0 0;\"\u003e\n  About KOEED ·\n  \u003ca href=\"\/it\/pages\/about-us\" style=\"color:#0056B3; text-decoration:underline;\"\u003eBrand overview\u003c\/a\u003e ·\n  \u003ca href=\"\/it\/pages\/about-china-sourcing-company\" style=\"color:#0056B3; text-decoration:underline;\"\u003eChina sourcing\u003c\/a\u003e ·\n  \u003ca href=\"\/it\/pages\/contact-us\" style=\"color:#0056B3; text-decoration:underline;\"\u003eContact us\u003c\/a\u003e ·\n  \u003ca href=\"\/it\/pages\/faq\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFAQs\u003c\/a\u003e ·\n  Email\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Rexroth%20GIV50-11%20Valve%20Position%20Switch\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e\n\u003c\/p\u003e\n","brand":"REXROTH","offers":[{"title":"Default Title","offer_id":43838104043705,"sku":"304934391635","price":331.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0268\/8476\/7929\/files\/REXROTH_GIV50_11_R900174537_Valve_Position_Switch_Sensor___REWROTH__1.webp?v=1775386716","url":"https:\/\/koeed.com\/it\/products\/1pcs-new-rexroth-sensor-giv50-11-r900174537-r901465833-valve-position-switch","provider":"KOEED","version":"1.0","type":"link"}