{"product_id":"sawana-js48s-2z-time-relay-dc24-12v-ac110-220v","title":"SAWANA JS48S-2Z Timer Relay DC24\/12V AC110\/220V","description":"\u003cstyle\u003e\n  \/* Base Container \u0026 Scope Isolation *\/\n  .koeed-wrapper {\n    width: 100%;\n    box-sizing: border-box;\n    color: #333333;\n    line-height: 1.6;\n  }\n  .koeed-wrapper *, .koeed-wrapper *::before, .koeed-wrapper *::after {\n    box-sizing: border-box;\n  }\n\n  \/* Headings \u0026 Typography *\/\n  .koeed-wrapper h2 {\n    color: #16c8c8;\n    border-left: 4px solid #16c8c8;\n    padding-left: 12px;\n    margin-top: 30px;\n    margin-bottom: 15px;\n    font-weight: 700;\n  }\n  .koeed-wrapper h3 {\n    color: #0056b3;\n    margin-top: 20px;\n    margin-bottom: 10px;\n    font-weight: 600;\n  }\n\n  \/* Callout Blockquote *\/\n  .koeed-quote {\n    background-color: #f4fcfc;\n    border-left: 4px solid #16c8c8;\n    padding: 15px;\n    margin: 20px 0;\n  }\n\n  \/* Responsive Tables *\/\n  .koeed-table-responsive {\n    width: 100%;\n    overflow-x: auto;\n    margin-bottom: 25px;\n    border: 1px solid #eeeeee;\n  }\n  .koeed-table {\n    width: 100%;\n    border-collapse: collapse;\n    text-align: left;\n  }\n  .koeed-table th {\n    background-color: #f4fcfc;\n    color: #0056b3;\n    font-weight: 600;\n    padding: 12px;\n    border-bottom: 2px solid #eeeeee;\n  }\n  .koeed-table td {\n    padding: 12px;\n    border-bottom: 1px solid #eeeeee;\n  }\n  .koeed-table tr:nth-child(even) {\n    background-color: #fafafa;\n  }\n  .koeed-table tr:nth-child(odd) {\n    background-color: #ffffff;\n  }\n\n  \/* Bullet Points \u0026 Lists *\/\n  .koeed-list {\n    padding-left: 20px;\n    margin-bottom: 20px;\n  }\n  .koeed-list li {\n    margin-bottom: 8px;\n  }\n\n  \/* Interactive Tool Styles *\/\n  .koeed-tool-container {\n    background-color: #ffffff;\n    border: 2px solid #16c8c8;\n    border-radius: 6px;\n    padding: 25px;\n    margin: 30px 0;\n  }\n  .koeed-tool-grid {\n    display: grid;\n    grid-template-columns: repeat(auto-fit, minmax(220px, 1fr));\n    gap: 20px;\n    margin-bottom: 20px;\n  }\n  .koeed-input-group {\n    display: flex;\n    flex-direction: column;\n  }\n  .koeed-input-group label {\n    font-weight: 600;\n    margin-bottom: 6px;\n    color: #333333;\n  }\n  .koeed-input-group input, .koeed-input-group select {\n    padding: 10px;\n    border: 1px solid #eeeeee;\n    border-radius: 4px;\n    background-color: #fafafa;\n  }\n  .koeed-input-group input:focus, .koeed-input-group select:focus {\n    outline: none;\n    border-color: #16c8c8;\n    background-color: #ffffff;\n  }\n  .koeed-btn {\n    background-color: #16c8c8;\n    color: #ffffff;\n    border: none;\n    padding: 12px 20px;\n    border-radius: 4px;\n    cursor: pointer;\n    font-weight: 600;\n    transition: background-color 0.2s ease;\n  }\n  .koeed-btn:hover {\n    background-color: #0056b3;\n  }\n  .koeed-result-panel {\n    background-color: #f4fcfc;\n    border: 1px dashed #16c8c8;\n    padding: 15px;\n    margin-top: 20px;\n    border-radius: 4px;\n  }\n  .koeed-result-value {\n    font-size: 1.4em;\n    font-weight: 700;\n    color: #0056b3;\n    margin-bottom: 5px;\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"koeed-wrapper\"\u003e\n\n  \u003c!-- SECTION 1: Engineer's Quick Brief --\u003e\n  \u003ch2\u003eEngineer's Quick Brief\u003c\/h2\u003e\n  \u003cdiv class=\"koeed-quote\"\u003e\n    \u003cul class=\"koeed-list\" style=\"margin-bottom: 0;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eHighly Visible Digital Readout:\u003c\/strong\u003e Crystal-clear LED display screen engineered to prevent parallax tracking errors during fast production floor diagnostics.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eFlexible Multi-Voltage Coils:\u003c\/strong\u003e Wide configuration options supporting direct grid hookups across \u003cstrong\u003eDC 24V\/12V\u003c\/strong\u003e or standard industrial alternating lines \u003cstrong\u003eAC 110V\/220V\u003c\/strong\u003e layouts.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eDual-Group SPDT Contact Topology:\u003c\/strong\u003e Integrates a robust \u003cstrong\u003e2Z\u003c\/strong\u003e terminal set (Dual Changeover Contacts) to govern high-capacity synchronous motor switching and safety logic loops securely.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- SECTION 2: SEO Introduction --\u003e\n  \u003cp\u003eThe \u003cstrong\u003eSAWANA JS48S-2Z\u003c\/strong\u003e is a premium, high-density industrial \u003cstrong\u003edigital timer relay\u003c\/strong\u003e designed for deterministic process scheduling and automatic cycle sequence control. Belonging to the industry-standard 48x48mm panel cutout family, this high-performance \u003cstrong\u003etime relay\u003c\/strong\u003e offers an incredibly wide timing spectrum ranging from fractions of a second up to hundreds of hours. Engineered with universal voltage adaptability covering \u003cstrong\u003eDC24V\/12V\u003c\/strong\u003e and \u003cstrong\u003eAC110V\/220V\u003c\/strong\u003e control grids, the JS48S-2Z provides automation technicians with precise thumbwheel switch adjustment matrix setups, rendering it an optimized solution for star-delta motor starters, automated industrial ovens, and packaging line conveyors.\u003c\/p\u003e\n\n  \u003c!-- SECTION 3: Technical Specifications --\u003e\n  \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n  \u003cdiv class=\"koeed-table-responsive\"\u003e\n    \u003ctable class=\"koeed-table\"\u003e\n      \u003cthead\u003e\n        \u003ctr\u003e\n          \u003cth\u003eEngineering Parameter\u003c\/th\u003e\n          \u003cth\u003eTechnical Classification\u003c\/th\u003e\n          \u003cth\u003eOperational Value\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eBrand Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eOEM Brand Lineage\u003c\/td\u003e\n          \u003ctd\u003eSAWANA\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eModel Identifier\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eProduct Model Reference\u003c\/td\u003e\n          \u003ctd\u003eJS48S-2Z Series\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eDisplay Architecture\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003ePanel Readout System\u003c\/td\u003e\n          \u003ctd\u003eHigh-contrast digital LED screen display\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eControl Voltage Options\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eCoil Voltage Source Limits\u003c\/td\u003e\n          \u003ctd\u003eDC 12V, DC 24V, AC 110V, AC 220V (Model Option Specific)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eOutput Pole Matrix Style\u003c\/td\u003e\n          \u003ctd\u003e2Z (2 Form C \/ Double Pole Double Throw - DPDT Changeover Array)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eContact Capacity Rating\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eResistive Load Amperage\u003c\/td\u003e\n          \u003ctd\u003e5A at 250V AC \/ 5A at 28V DC (Max Continuous Boundary)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eTiming Scope Matrix\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eAdjustable Scaling Units\u003c\/td\u003e\n          \u003ctd\u003e0.01s - 99s, 1m - 99m, 1h - 99h (Multi-unit selector array)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eRepeatability Error\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eTiming Accuracy Drift\u003c\/td\u003e\n          \u003ctd\u003e≤ ±1% Full Scale Configuration\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eMechanical Base Type\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eSocket Mounting Geometry\u003c\/td\u003e\n          \u003ctd\u003eStandard 8-Pin Round Circular Plug-in Socket Installation\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eChassis Assembly Profile\u003c\/td\u003e\n          \u003ctd\u003eFlush panel mount fitting or standard DIN-rail base fitting\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- SECTION 4: Application Matrix --\u003e\n  \u003ch2\u003eApplication Matrix\u003c\/h2\u003e\n  \u003cdiv class=\"koeed-table-responsive\"\u003e\n    \u003ctable class=\"koeed-table\"\u003e\n      \u003cthead\u003e\n        \u003ctr\u003e\n          \u003cth\u003eTarget Industrial System\u003c\/th\u003e\n          \u003cth\u003eDeployment Purpose\u003c\/th\u003e\n          \u003cth\u003eEngineering Value Delivered\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eStar-Delta Motor Starters\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eTransition delay timing logic\u003c\/td\u003e\n          \u003ctd\u003eGoverns the strict sub-second separation gap required between star dropping and delta activation, protecting coils from interlocking shorts.\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eIndustrial Kilns \u0026amp; Baking Ovens\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eSustained heat cycle timing\u003c\/td\u003e\n          \u003ctd\u003eProvides high repeatability accuracy over extended hourly profiles, maintaining strict thermal recipe guidelines.\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eConveyor Material Dosing Lines\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eRepetitive material staging loops\u003c\/td\u003e\n          \u003ctd\u003eDual SPDT contact output tracks batch material release gates independently without software overhead or PLC delay risks.\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- SECTION 5: Koeed B2B Interactive Tool --\u003e\n  \u003ch2\u003eKoeed B2B Tool: 8-Pin Relay Pinout Mapping \u0026amp; Time-Sequence Calibrator\u003c\/h2\u003e\n  \u003cp\u003eField specialists must map terminal socket wire lines correctly to prevent coil failures and optimize load time delays. Select your model specification parameters below to decode pin assignments and calculate sequence variables.\u003c\/p\u003e\n  \n  \u003cdiv class=\"koeed-tool-container\"\u003e\n    \u003cdiv class=\"koeed-tool-grid\"\u003e\n      \u003cdiv class=\"koeed-input-group\"\u003e\n        \u003clabel for=\"koeed-coil-volt\"\u003eTarget Coil Input Variant:\u003c\/label\u003e\n        \u003cselect id=\"koeed-coil-volt\" onchange=\"koeedCalculateTimerRelay()\"\u003e\n          \u003coption value=\"DC24\"\u003eDC 24V System Line\u003c\/option\u003e\n          \u003coption value=\"DC12\"\u003eDC 12V System Line\u003c\/option\u003e\n          \u003coption value=\"AC220\" selected\u003eAC 220V Grid Mains\u003c\/option\u003e\n          \u003coption value=\"AC110\"\u003eAC 110V Grid Mains\u003c\/option\u003e\n        \u003c\/select\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"koeed-input-group\"\u003e\n        \u003clabel for=\"koeed-time-set\"\u003eTarget Time Duration Value:\u003c\/label\u003e\n        \u003cinput type=\"number\" id=\"koeed-time-set\" min=\"1\" max=\"99\" value=\"10\" oninput=\"koeedCalculateTimerRelay()\"\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"koeed-input-group\"\u003e\n        \u003clabel for=\"koeed-time-unit\"\u003eTime Scaling Base Metric:\u003c\/label\u003e\n        \u003cselect id=\"koeed-time-unit\" onchange=\"koeedCalculateTimerRelay()\"\u003e\n          \u003coption value=\"s\" selected\u003eSeconds (s Pool)\u003c\/option\u003e\n          \u003coption value=\"m\"\u003eMinutes (m Pool)\u003c\/option\u003e\n          \u003coption value=\"h\"\u003eHours (h Pool)\u003c\/option\u003e\n        \u003c\/select\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n    \n    \u003cdiv class=\"koeed-result-panel\"\u003e\n      \u003cdiv class=\"koeed-result-value\" id=\"koeed-pin-output\"\u003e8-Pin Base Layout: Pins 2 \u0026amp; 7 are Coil Terminals\u003c\/div\u003e\n      \u003cdiv style=\"font-size: 0.9em; font-weight: 600; color: #333333;\" id=\"koeed-logic-output\"\u003eContact Matrix Logic: Pins 1-4 (NC), 1-3 (NO) | Pins 8-5 (NC), 8-6 (NO)\u003c\/div\u003e\n      \u003cdiv style=\"margin-top: 8px; font-size: 0.85em; color: #666666;\" id=\"koeed-timer-advice\"\u003eTimer setting corresponds to a total duration boundary of 10 seconds. Output capacity handles up to 5 Amperes resistive current loads.\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cnoscript\u003e\n    \u003cdiv class=\"koeed-quote\"\u003e\n      \u003cstrong\u003eEngineering Field Base Wiring Guide:\u003c\/strong\u003e The SAWANA JS48S-2Z employs standard round 8-pin circular geometry allocations. Pin pairs 2 and 7 drive the primary excitation coil winding circuit. Node 1 acts as common reference targeting contact pins 3 (Normally Open) and 4 (Normally Closed); Node 8 mirrors this function targeting contact pins 6 (Normally Open) and 5 (Normally Closed).\n    \u003c\/div\u003e\n  \u003c\/noscript\u003e\n\n  \u003cscript\u003e\n    function koeedCalculateTimerRelay() {\n      var coil = document.getElementById('koeed-coil-volt').value;\n      var value = parseFloat(document.getElementById('koeed-time-set').value);\n      var unit = document.getElementById('koeed-time-unit').value;\n      \n      if (isNaN(value) || value \u003c= 0) {\n        return;\n      }\n      if (value \u003e 99) {\n        value = 99;\n        document.getElementById('koeed-time-set').value = 99;\n      }\n      \n      var unitFull = \"seconds\";\n      if (unit === \"m\") unitFull = \"minutes\";\n      if (unit === \"h\") unitFull = \"hours\";\n      \n      var pinText = \"8-Pin Octal Base Layout: Pins 2 \u0026 7 map to the Power Supply Coil Nodes.\";\n      var logicText = \"Group 1: Pin 1 (COM) blocks Pin 4 (NC) \/ joins Pin 3 (NO) | Group 2: Pin 8 (COM) blocks Pin 5 (NC) \/ joins Pin 6 (NO) post-delay.\";\n      \n      if (coil.indexOf(\"DC\") !== -1) {\n        pinText = \"8-Pin Octal Base Layout: Pins 2 \u0026 7 drive DC Coil. Wire Pin 2 to Negative (-GND) and Pin 7 to Positive (+) polarity lines.\";\n      }\n      \n      document.getElementById('koeed-pin-output').innerText = pinText;\n      document.getElementById('koeed-logic-output').innerText = logicText;\n      document.getElementById('koeed-timer-advice').innerText = \"Calibrated Parameter Profile: Configured duration is precisely \" + value + \" \" + unitFull + \". Direct current or alternating current inductive load currents must retain safe headroom under the 5A full-scale ceiling.\";\n    }\n    \n    window.addEventListener('DOMContentLoaded', koeedCalculateTimerRelay);\n  \u003c\/script\u003e\n\n  \u003c!-- SECTION 6: Troubleshooting \u0026 FAQ --\u003e\n  \u003ch2\u003eTroubleshooting \u0026amp; Electrical Diagnostics FAQ\u003c\/h2\u003e\n  \n  \u003ch3\u003eQ1: Why triggers the JS48S-2Z digital display screen to activate but fail to shift contact output states after timing out?\u003c\/h3\u003e\n  \u003cp\u003eThis defect typically indicates that the input control voltage tracks significantly lower than the minimum nominal excitation boundary, or the internal copper contacts have experienced advanced electrical pitting. Electronic timer circuits can initialize their LED displays at low source metrics (down to 75% of spec), but the internal magnetic coil assembly requires a full 85% to 110% potential range to overcome return spring resistance and physically slide the mechanical armature. Measure across socket terminal nodes **2 and 7** using a digital multimeter under loaded states to verify line potential integrity.\u003c\/p\u003e\n\n  \u003ch3\u003eQ2: How can technicians configure the device terminal layout to clear memory states instantly without cutting main panel line power?\u003c\/h3\u003e\n  \u003cp\u003eThe standard JS48S-2Z variant achieves timing zero-reset parameters by briefly dropping coil power across nodes 2 and 7. However, if your specific variant card layout features dedicated internal auxiliary reset terminals, do not route line potential to those logic blocks. If rapid panel recycling is an engineering requirement, wire a **Normally Closed momentary push button switch** in series directly along the steering line leading into terminal pin 7 to allow field teams to clear cycles manually.\u003c\/p\u003e\n\n  \u003ch3\u003eQ3: What root conditions cause the digital relay screen to continuously flicker or execute erratic counting jumps?\u003c\/h3\u003e\n  \u003cp\u003eFlickering displays or random numerical jumps point toward heavy alternating electromagnetic noise (EMI) leaking into low-voltage steering conduits, or severe high-frequency voltage ripples propagating down the direct current auxiliary loop power distribution rail. Ensure all low-voltage control conductors are completely separated from heavy AC motor lines, switching variable frequency drive (VFD) tracks, and inductive braking lines. If voltage ripples cannot be eradicated, integrate a dedicated industrial **surge suppressor filter module** right before the socket entry nodes.\u003c\/p\u003e\n\n  \u003c!-- SECTION 7: Cross-Reference \u0026 Selection Guide --\u003e\n  \u003ch3\u003eCross-Reference Guide\u003c\/h3\u003e\n  \u003cp\u003eWhen tracking equipment databases, modernizing legacy automation modules, or organizing facility backup warehouse stock levels, note the following direct selection compatibility parameters:\u003c\/p\u003e\n  \u003cul class=\"koeed-list\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirect Drop-in Matching:\u003c\/strong\u003e Fits seamlessly as a direct dimensional and structural electrical replacement alternative for standard 8-pin digital display time relays sharing the 48mm square template layout, such as classic DH48S, H5CX, or Omron H3CR style series configurations provided pin definitions align with your application profile.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSystem Platform Interoperability:\u003c\/strong\u003e Integrates smoothly into standardized control enclosures alongside low-voltage thermal overload contactors from global apparatus brands like Schneider Electric (LC1-D series), Siemens (3RT series modules), and ABB, provided standard pilot current requirements fit the continuous 5A contact threshold.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Structured JSON-LD Data for AI Scraping Engines --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@graph\": [\n    {\n      \"@type\": \"FAQPage\",\n      \"mainEntity\": [\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Why triggers the JS48S-2Z digital display screen to activate but fail to shift contact output states after timing out?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"This occurs when the control voltage drops below the minimum threshold required to actuate the magnetic armature, despite being high enough to illuminate the digital LED screen. Check terminals 2 and 7 to ensure the potential falls within the nominal 85% to 110% specification window.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"How can technicians configure the device terminal layout to clear memory states instantly without cutting main panel line power?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"The JS48S-2Z resets its cycle timing when excitation power across pins 2 and 7 is broken. Install a Normally Closed (NC) momentary push button switch in series along the line to terminal pin 7 to enable manual resetting capability.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"What root conditions cause the digital relay screen to continuously flicker or execute erratic counting jumps?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Flickering or random counting is caused by EMI noise leaking into control conduits from neighboring high-power AC cables or heavy harmonic ripples on the DC supply line. Separate signal wiring from motor or VFD runs and implement inline surge filtering if needed.\"\n          }\n        }\n      ]\n    },\n    {\n      \"@type\": \"WebApplication\",\n      \"name\": \"8-Pin Relay Pinout Mapping \u0026 Time-Sequence Calibrator\",\n      \"applicationCategory\": \"BusinessApplication\",\n      \"operatingSystem\": \"All\",\n      \"browserRequirements\": \"Requires HTML5 rendering compliance. JavaScript engine must be active.\",\n      \"description\": \"An interactive technical utility developed for low-voltage electrical technicians to map standard octal round 8-pin time relay connection socket assignments and evaluate contact logic performance parameters.\"\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"KOEED","offers":[{"title":"Default Title","offer_id":44236281577657,"sku":"166326667304","price":88.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0268\/8476\/7929\/files\/SAWANA_JS48S_2Z_Timer_Relay_DC24_12V_AC110_220V___SAWANA__1.webp?v=1775522236","url":"https:\/\/koeed.com\/ko\/products\/sawana-js48s-2z-time-relay-dc24-12v-ac110-220v","provider":"KOEED","version":"1.0","type":"link"}