{"product_id":"1pcs-for-mettler-toledo-rally-s-type-tsc-load-cell-tsc-50kg-100-200-300-500-1000","title":"FOR METTLER TOLEDO Rally S-type TSC Load Cell TSC-500","description":"\u003ch1 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:28px; line-height:36px; margin:0 0 8px 0;\"\u003e\n  Mettler Toledo Rally S-Type TSC Load Cell — TSC-50kg \/ 100 \/ 200 \/ 300 \/ 500 \/ 1000 kg\n\u003c\/h1\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#0056B3; font-size:14px; line-height:22px; letter-spacing:1px; text-transform:uppercase; margin:0 0 24px 0;\"\u003e\n  METTLER TOLEDO · RALLY TSC · S-TYPE TENSION LOAD CELL · IN STOCK\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:0 0 16px 0;\"\u003e\n  The \u003cstrong\u003eMettler Toledo Rally TSC\u003c\/strong\u003e is a precision \u003cstrong\u003eS-type \/ Z-beam tension-compression load cell\u003c\/strong\u003e built for industrial weighing and force measurement. Available in 50 kg, 100 kg, 200 kg, 300 kg, 500 kg, 1000 kg and 2000 kg capacity variants with OIML C2 \/ C3 \/ C4 accuracy classes, the TSC family combines a hermetically welded stainless steel \/ nickel-alloy body, IP68 \/ IP69K sealing and ATEX \/ IECEx \/ FM \/ CSA hazardous-area certification. In factory automation the TSC is typically paired with weighing modules and PLC-based transmitters from \u003ca href=\"\/no\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e, \u003ca href=\"\/no\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e, \u003ca href=\"\/no\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e, \u003ca href=\"\/no\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e, \u003ca href=\"\/no\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e, \u003ca href=\"\/no\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e, \u003ca href=\"\/no\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e, \u003ca href=\"\/no\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic\u003c\/a\u003e or \u003ca href=\"\/no\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e, and KOEED supports both the cell itself and the surrounding \u003ca href=\"\/no\/collections\" style=\"color:#0056B3; text-decoration:underline;\"\u003eindustrial automation spare-parts\u003c\/a\u003e ecosystem.\n\u003c\/p\u003e\n\n\u003c!-- ============ H2 (1) Key Technical Specifications ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Key Technical Specifications \u0026amp; Overview\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  The Rally TSC is built on bonded-foil strain-gauge technology with a normalized 2 mV\/V output and 4-wire or 6-wire sense-line options, so the same housing can serve trade-approved platform scales, batching skids and high-precision force-test rigs. The threaded end-loadings accept standard eye-bolts, rod-ends or load buttons, which keeps mechanical installation simple and field-replaceable.\n\u003c\/p\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #eeeeee; font-family:Arial, Helvetica, sans-serif; font-size:14px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eMettler Toledo (Swiss \/ US weighing specialist)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eRally TSC — S-type \/ Z-beam tension-compression\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eModel Range\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eTSC-50kg \/ 100 \/ 200 \/ 300 \/ 500 \/ 1000 (2000 kg available on request)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eCell Type\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eS-type \/ Z-beam tension-compression, threaded end-loadings\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eCapacity Variants\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e50 kg, 100 kg, 200 kg, 300 kg, 500 kg, 1000 kg, 2000 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eAccuracy Class\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eOIML C2 \/ C3 \/ C4 (application-dependent)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eRated Output\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e2 mV\/V ± 0.1 % (normalized)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eExcitation Voltage\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e5 – 15 V DC (10 V recommended)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eWiring\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e4-wire or 6-wire with sense lines for long cable compensation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eMaterial\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eHermetically welded stainless steel \/ nickel-alloy body\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eIngress Protection\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eIP68 \/ IP69K (submersible, high-pressure wash-down)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eHazardous-Area Approval\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eIECEx \/ ATEX \/ FM \/ CSA (zone- and division-class dependent)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e−40 °C to +80 °C (compensated 0 °C to +40 °C standard, wide-temp option)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSafe Overload \/ Ultimate\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e150 % rated capacity \/ 300 % rated capacity\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eTypical Application\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003ePlatform scale, truck scale, hopper \/ tank \/ silo weighing, batching, crane \/ hanging scale, force-test rig, food \u0026amp; pharma process weighing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eStock Status\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        In stock — quote within 24 hours at \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Mettler-Toledo%20Rally%20TSC%20Load%20Cell\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c!-- ============ H2 (2) Application Scenarios ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Application Scenarios — Where the TSC Fits\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  The Rally TSC's universal S-type geometry and broad capacity spread make it one of the most versatile weighing cells in Mettler Toledo's catalog. Typical deployments include:\n\u003c\/p\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial platform scales \u0026amp; truck scales\u003c\/strong\u003e — single-cell or multi-cell weighbridges where the threaded end-loadings accept standard eye-bolts or load buttons.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHopper, tank \u0026amp; silo weighing\u003c\/strong\u003e — three- or four-cell suspension systems for batch inventory control, often integrated with \u003ca href=\"\/no\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e or \u003ca href=\"\/no\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e weighing modules.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBatching, filling \u0026amp; dosing skids\u003c\/strong\u003e — gravimetric filling for food, beverage, and chemical packaging lines, typically driven by \u003ca href=\"\/no\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e or \u003ca href=\"\/no\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e PLCs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCrane scales \u0026amp; hanging scales\u003c\/strong\u003e — 50 kg to 1000 kg tension cells on overhead hoists in steel mills, ports, and warehouses.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eForce measurement \u0026amp; load-test rigs\u003c\/strong\u003e — tension and compression testing in quality labs and on production lines, with readings logged to a \u003ca href=\"\/no\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e vision-guided inspection cell or a SCADA host.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProcess weighing in food, pharma \u0026amp; chemical plants\u003c\/strong\u003e — IP69K wash-down rated cells in hygienic stainless housings, certified for hazardous areas.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobotics \u0026amp; CNC force feedback\u003c\/strong\u003e — end-effector load monitoring on \u003ca href=\"\/no\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e and \u003ca href=\"\/no\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e robot arms, or spindle force sensing on machine-tools monitored by a \u003ca href=\"\/no\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e Modicon controller.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c!-- ============ H2 (3) Integration \u0026 Wiring Notes ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Integration \u0026amp; Wiring Notes\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  The TSC outputs a low-level 2 mV\/V differential signal, so cable routing, shielding, and grounding deserve the same attention as the cell selection itself. The points below are the ones that most often decide between a clean reading and a noisy one in the field:\n\u003c\/p\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003e4-wire vs 6-wire\u003c\/strong\u003e — choose 6-wire (with separate sense leads) for any cable run over 3 m, or wherever the excitation voltage drop would otherwise degrade the zero stability. 4-wire is acceptable for short jumper cables inside an instrument enclosure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExcitation \u0026amp; sense wiring\u003c\/strong\u003e — use a regulated 10 V DC supply from a dedicated weighing transmitter or analog input module. Sharing excitation with relays or solenoids on the same rail will inject common-mode noise.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding \u0026amp; grounding\u003c\/strong\u003e — terminate the cable shield at the instrument end only (single-point ground). Float the cell end to avoid ground loops. Route weighing cables at least 200 mm away from VFD, servo, or welding cables.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePLC analog input scaling\u003c\/strong\u003e — convert mV\/V back to engineering units in the controller: \u003cem\u003eWeight = (V\u003csub\u003eout\u003c\/sub\u003e − Zero) × Capacity ÷ (Sensitivity × Excitation)\u003c\/em\u003e. The KOEED \u003ca href=\"\/no\/pages\/plc-analog-calculator\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePLC Analog Calculator\u003c\/a\u003e saves the math on 4-20 mA loops; for hex-coded PLC words, the \u003ca href=\"\/no\/pages\/plc-hex-float-converter\" style=\"color:#0056B3; text-decoration:underline;\"\u003eHex-to-Float converter\u003c\/a\u003e is the right tool.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMulti-cell summation boxes\u003c\/strong\u003e — when several TSC cells share one vessel, use a matched-cell junction box so individual cell outputs can be trimmed before summing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommunication with the controller\u003c\/strong\u003e — pair the load cell with a Modbus, EtherNet\/IP, or PROFIBUS weighing transmitter; the same transmitter can be polled by \u003ca href=\"\/no\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e Modicon, \u003ca href=\"\/no\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic\u003c\/a\u003e FP, or any of the nine supported PLC families. If you are unsure which transmitter matches your existing rack, send the project specs to \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Mettler-Toledo%20Rally%20TSC%20Load%20Cell\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e for a recommended bundle.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c!-- ============ H2 (4) Installation \u0026 Commissioning Tips ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Installation \u0026amp; Commissioning Tips\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  An S-type load cell is mechanically simple but mechanically unforgiving — a few field habits will extend its service life and protect the calibration warranty.\n\u003c\/p\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting alignment\u003c\/strong\u003e — the threaded eye-bolts at each end must load the cell axially. Side load, twisting, or off-axis pull will bias the reading and may exceed the cell's side-load rating.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSelf-aligning hardware\u003c\/strong\u003e — use rod-end bearings or self-aligning washers at both ends so that thermal expansion or structural deflection does not pre-load the cell.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque to spec\u003c\/strong\u003e — over-tightening the threaded end-fittings is the most common cause of zero-shift. Follow the Mettler Toledo datasheet torque values for the capacity variant being installed.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMechanical stops \/ safety straps\u003c\/strong\u003e — for overhead or lifting applications, install mechanical stops or safety straps sized to 150 % of the rated capacity so a sudden overload never reaches the cell's ultimate-load limit.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePre-load warm-up\u003c\/strong\u003e — apply the rated load three to five times before the final calibration to bed-in the strain gauges and stabilise the zero reading.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCalibration workflow\u003c\/strong\u003e — calibrate with calibrated test weights in the final installed position; document zero, span, and linearity at the four corners of the platform. For unusual capacities, send the project specs to \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Mettler-Toledo%20Rally%20TSC%20Load%20Cell\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e for a recommended cell capacity and corner-load check.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRe-zero after first loaded cycle\u003c\/strong\u003e — strain-gauge cells can drift slightly after the first full-scale loading; re-zero the transmitter and lock the calibration before going into production.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePeriodic verification\u003c\/strong\u003e — for trade-approved applications, repeat the linearity check on the schedule defined by the local metrology authority. For process cells, a quarterly span check is typical.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c!-- ============ H2 (5) Procurement, Warranty \u0026 Lead Time ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Procurement, Warranty \u0026amp; Lead Time\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  Mettler Toledo load cells are sourced into a global weighing market where OEM allocation can stretch lead times. KOEED is not the OEM — we are an independent multi-brand \u003ca href=\"\/no\/pages\/about-china-sourcing-company\" style=\"color:#0056B3; text-decoration:underline;\"\u003eChina sourcing company\u003c\/a\u003e that maintains stock of the TSC family and the surrounding automation parts so the cell can be on its way without a 12-week factory wait.\n\u003c\/p\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStocked capacities\u003c\/strong\u003e — 50 kg, 100 kg, 200 kg, 300 kg, 500 kg and 1000 kg variants are normally available from our Hong Kong \/ Shenzhen warehouse. The 2000 kg variant and C4 accuracy grades are quoted on request.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLead time\u003c\/strong\u003e — in-stock units ship within 1-3 business days after payment confirmation. Special-order accuracy classes or non-standard cable lengths add 2-4 weeks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWorldwide shipping\u003c\/strong\u003e — DHL, FedEx, UPS and sea freight; DDP and EXW terms both available. We package weighing cells in foam-lined anti-static boxes so the calibration is not disturbed in transit.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty \u0026amp; authenticity\u003c\/strong\u003e — every TSC ships with its Mettler Toledo calibration certificate, datasheet and serial number traceable through our \u003ca href=\"\/no\/pages\/real-time-sales-list\" style=\"color:#0056B3; text-decoration:underline;\"\u003ereal-time sales records\u003c\/a\u003e. KOEED provides a 12-month replacement warranty against manufacturing defect on stock units.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuotation process\u003c\/strong\u003e — send a one-line RFQ to \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Mettler-Toledo%20Rally%20TSC%20Load%20Cell\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e, or upload a full BOM via the \u003ca href=\"\/no\/pages\/request-for-quote\" style=\"color:#0056B3; text-decoration:underline;\"\u003eCreate a Quote\u003c\/a\u003e form. You will get a confirmation of stock and a firm quotation within 24 business hours.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEngineer support\u003c\/strong\u003e — our team can also cross-reference a legacy Mettler Toledo cell (such as the S-type SLB-200 \/ 500 \/ 1000) to the equivalent TSC variant, or recommend a 9-brand PLC and transmitter bundle — Allen-Bradley, Siemens, Mitsubishi, Omron, Fanuc, Schneider, Yaskawa, Panasonic, or KEYENCE — to complete the weighing loop. For hard-to-find or EOL weighing parts, the \u003ca href=\"\/no\/pages\/ai-tool\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKOEED AI Diagnostic Tool\u003c\/a\u003e can take a nameplate photo and suggest a cross reference in seconds.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustry context\u003c\/strong\u003e — load cells are commonly replaced during the same shutdown window as a PLC retrofit; pairing the order with a \u003ca href=\"\/no\/collections\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePLC module\u003c\/a\u003e, an HMI panel or a servo drive can save on combined shipping and customs clearance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c!-- ============ Inquiry CTA ============ --\u003e\n\u003cdiv style=\"background-color:#16c8c8; padding:24px 32px; margin:32px 0; text-align:center; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003ch3 style=\"margin:0 0 12px 0; color:#ffffff; font-size:20px; line-height:28px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Need the TSC Load Cell or a full weighing-system BOM?\n  \u003c\/h3\u003e\n  \u003cp style=\"margin:0 0 16px 0; color:#ffffff; font-size:15px; line-height:22px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Send your part list to \u003cstrong\u003eMoritta@KOEED.COM\u003c\/strong\u003e and get availability \u0026amp; price within 24 hours.\n  \u003c\/p\u003e\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Mettler-Toledo%20Rally%20TSC%20Load%20Cell\" style=\"display:inline-block; background-color:#ffffff; color:#0056B3; padding:12px 24px; text-decoration:none; font-weight:bold; border-radius:4px; font-size:15px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Request a Quote →\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"border:1px solid #0056B3; padding:16px 24px; margin:16px 0; text-align:left; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 8px 0; color:#111111; font-size:15px; line-height:22px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Looking for more weighing or automation parts in the same project?\n  \u003c\/p\u003e\n  \u003ca href=\"\/no\/collections\/allen-bradley\" style=\"display:inline-block; color:#0056B3; padding:6px 18px; text-decoration:none; font-weight:bold; border:1px solid #0056B3; border-radius:4px; font-size:14px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Browse Allen-Bradley →\n  \u003c\/a\u003e\n   \n  \u003ca href=\"\/no\/collections\/siemens\" style=\"display:inline-block; color:#0056B3; padding:6px 18px; text-decoration:none; font-weight:bold; border:1px solid #0056B3; border-radius:4px; font-size:14px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Browse Siemens →\n  \u003c\/a\u003e\n   \n  \u003ca href=\"\/no\/collections\/mitsubishi\" style=\"display:inline-block; color:#0056B3; padding:6px 18px; text-decoration:none; font-weight:bold; border:1px solid #0056B3; border-radius:4px; font-size:14px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Browse Mitsubishi →\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"border:1px solid #eeeeee; background-color:#f4fcfc; padding:16px 24px; margin:16px 0; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 4px 0; color:#111111; font-size:15px; font-weight:bold; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    \u0026gt; Need to scale mV\/V into engineering units or look up a weighing error code?\n  \u003c\/p\u003e\n  \u003cp style=\"margin:0 0 8px 0; color:#333333; font-size:14px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Try the free KOEED online toolset — no login, no sign-up.\n  \u003c\/p\u003e\n  \u003ca href=\"\/no\/pages\/plc-analog-calculator\" style=\"color:#0056B3; text-decoration:underline; font-weight:bold; font-size:14px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Open PLC Analog Calculator\n  \u003c\/a\u003e\n   | \n  \u003ca href=\"\/no\/pages\/plc-error-code-lookup\" style=\"color:#0056B3; text-decoration:underline; font-weight:bold; font-size:14px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Search PLC Error Code Database\n  \u003c\/a\u003e\n   | \n  \u003ca href=\"\/no\/pages\/ai-tool\" style=\"color:#0056B3; text-decoration:underline; font-weight:bold; font-size:14px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Try the AI Diagnostic Tool\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#555555; font-size:13px; line-height:20px; margin:24px 0 0 0;\"\u003e\n  Cross-references: see also \u003ca href=\"\/no\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron SYSMAC PLCs\u003c\/a\u003e, \u003ca href=\"\/no\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc CNC parts\u003c\/a\u003e, \u003ca href=\"\/no\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider Modicon\u003c\/a\u003e, \u003ca href=\"\/no\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa servo drives\u003c\/a\u003e, \u003ca href=\"\/no\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic FP PLCs\u003c\/a\u003e, \u003ca href=\"\/no\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE vision systems\u003c\/a\u003e, and the latest \u003ca href=\"\/no\/blogs\/daily-plc-news\" style=\"color:#0056B3; text-decoration:underline;\"\u003eDaily PLC News\u003c\/a\u003e for weighing-instrument firmware updates. For full project galleries, browse \u003ca href=\"\/no\/pages\/our-gallery\" style=\"color:#0056B3; text-decoration:underline;\"\u003eour gallery\u003c\/a\u003e or read the \u003ca href=\"\/no\/pages\/faq\" style=\"color:#0056B3; text-decoration:underline;\"\u003eengineer FAQ\u003c\/a\u003e. Email \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Mettler-Toledo%20Rally%20TSC%20Load%20Cell\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e to start your RFQ.\n\u003c\/p\u003e\n","brand":"METTLER_TOLEDO","offers":[{"title":"Default Title","offer_id":43852380897465,"sku":"303922371606","price":224.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0268\/8476\/7929\/files\/s-l1600_6874f957-a95d-4a02-ad2e-4a3342b00bde.jpg?v=1712166494","url":"https:\/\/koeed.com\/no\/products\/1pcs-for-mettler-toledo-rally-s-type-tsc-load-cell-tsc-50kg-100-200-300-500-1000","provider":"KOEED","version":"1.0","type":"link"}