{"product_id":"new-kompass-apsd-40-1-pressure-switch","title":"New Kompass APSD-40-1 Pressure Switch - Professional Pressure Switch by Koppar","description":"\u003cstyle\u003e\n  \/* Base Container \u0026 Scope Isolation *\/\n  .koeed-wrapper {\n    width: 100%;\n    box-sizing: border-box;\n    color: #333333;\n    line-height: 1.6;\n  }\n  .koeed-wrapper *, .koeed-wrapper *::before, .koeed-wrapper *::after {\n    box-sizing: border-box;\n  }\n\n  \/* Headings \u0026 Typography *\/\n  .koeed-wrapper h2 {\n    color: #16c8c8;\n    border-left: 4px solid #16c8c8;\n    padding-left: 12px;\n    margin-top: 30px;\n    margin-bottom: 15px;\n    font-weight: 700;\n  }\n  .koeed-wrapper h3 {\n    color: #0056b3;\n    margin-top: 20px;\n    margin-bottom: 10px;\n    font-weight: 600;\n  }\n\n  \/* Callout Blockquote *\/\n  .koeed-quote {\n    background-color: #f4fcfc;\n    border-left: 4px solid #16c8c8;\n    padding: 15px;\n    margin: 20px 0;\n  }\n\n  \/* Responsive Tables *\/\n  .koeed-table-responsive {\n    width: 100%;\n    overflow-x: auto;\n    margin-bottom: 25px;\n    border: 1px solid #eeeeee;\n  }\n  .koeed-table {\n    width: 100%;\n    border-collapse: collapse;\n    text-align: left;\n  }\n  .koeed-table th {\n    background-color: #f4fcfc;\n    color: #0056b3;\n    font-weight: 600;\n    padding: 12px;\n    border-bottom: 2px solid #eeeeee;\n  }\n  .koeed-table td {\n    padding: 12px;\n    border-bottom: 1px solid #eeeeee;\n  }\n  .koeed-table tr:nth-child(even) {\n    background-color: #fafafa;\n  }\n  .koeed-table tr:nth-child(odd) {\n    background-color: #ffffff;\n  }\n\n  \/* Bullet Points \u0026 Lists *\/\n  .koeed-list {\n    padding-left: 20px;\n    margin-bottom: 20px;\n  }\n  .koeed-list li {\n    margin-bottom: 8px;\n  }\n\n  \/* Interactive Tool Styles *\/\n  .koeed-tool-container {\n    background-color: #ffffff;\n    border: 2px solid #16c8c8;\n    border-radius: 6px;\n    padding: 25px;\n    margin: 30px 0;\n  }\n  .koeed-tool-grid {\n    display: grid;\n    grid-template-columns: repeat(auto-fit, minmax(220px, 1fr));\n    gap: 20px;\n    margin-bottom: 20px;\n  }\n  .koeed-input-group {\n    display: flex;\n    flex-direction: column;\n  }\n  .koeed-input-group label {\n    font-weight: 600;\n    margin-bottom: 6px;\n    color: #333333;\n  }\n  .koeed-input-group input, .koeed-input-group select {\n    padding: 10px;\n    border: 1px solid #eeeeee;\n    border-radius: 4px;\n    background-color: #fafafa;\n  }\n  .koeed-input-group input:focus, .koeed-input-group select:focus {\n    outline: none;\n    border-color: #16c8c8;\n    background-color: #ffffff;\n  }\n  .koeed-btn {\n    background-color: #16c8c8;\n    color: #ffffff;\n    border: none;\n    padding: 12px 20px;\n    border-radius: 4px;\n    cursor: pointer;\n    font-weight: 600;\n    transition: background-color 0.2s ease;\n  }\n  .koeed-btn:hover {\n    background-color: #0056b3;\n  }\n  .koeed-result-panel {\n    background-color: #f4fcfc;\n    border: 1px dashed #16c8c8;\n    padding: 15px;\n    margin-top: 20px;\n    border-radius: 4px;\n  }\n  .koeed-result-value {\n    font-size: 1.4em;\n    font-weight: 700;\n    color: #0056b3;\n    margin-bottom: 5px;\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"koeed-wrapper\"\u003e\n\n  \u003c!-- SECTION 1: Engineer's Quick Brief --\u003e\n  \u003ch2\u003eEngineer's Quick Brief\u003c\/h2\u003e\n  \u003cdiv class=\"koeed-quote\"\u003e\n    \u003cul class=\"koeed-list\" style=\"margin-bottom: 0;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Microswitch Precision:\u003c\/strong\u003e Engineered by Koppar with a premium internal snap-action mechanism ensuring high-repeatability trip metrics across rigorous pressure cycles.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eField-Adjustable Deadband Stability:\u003c\/strong\u003e Offers direct control over critical cut-in and cut-out variables, eliminating pressure pulsations and preventing contact chattering in industrial hydraulic loops.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eRobust Hermetic Packaging:\u003c\/strong\u003e Hardened mechanical housing built to handle extreme vibrations, fluid surges, and volatile moisture ingress inside intensive automated enclosures.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- SECTION 2: SEO Introduction --\u003e\n  \u003cp\u003eThe \u003cstrong\u003eKompass APSD-40-1\u003c\/strong\u003e is a professional-grade, field-adjustable \u003cstrong\u003eindustrial pressure switch\u003c\/strong\u003e engineered by Koppar for high-fidelity fluid telemetry and systemic automation protection. Designed to execute instant circuit opening or closing when system lines cross critical thresholds, this reliable \u003cstrong\u003epressure controller switch\u003c\/strong\u003e serves as a robust safety interlock across pneumatic networks, central lubrication systems, and heavy hydraulic power units. Combining premium sealing materials with a highly stable microswitch array, the APSD-40-1 delivers low propagation delay and high vibration resistance, making it an excellent mechanical solution for minimizing machine downtime and guarding compressors against critical dry running or systemic overpressure events.\u003c\/p\u003e\n\n  \u003c!-- SECTION 3: Technical Specifications --\u003e\n  \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n  \u003cdiv class=\"koeed-table-responsive\"\u003e\n    \u003ctable class=\"koeed-table\"\u003e\n      \u003cthead\u003e\n        \u003ctr\u003e\n          \u003cth\u003eEngineering Parameter\u003c\/th\u003e\n          \u003cth\u003eTechnical Classification\u003c\/th\u003e\n          \u003cth\u003eOperational Baseline Value\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eBrand Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eOEM Brand Lineage\u003c\/td\u003e\n          \u003ctd\u003eKompass \/ Professional Pressure Switch by Koppar\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eModel Identifier\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eProduct Model Code\u003c\/td\u003e\n          \u003ctd\u003eAPSD-40-1 Variant Series\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eSwitch Category\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eHardware Specialization Class\u003c\/td\u003e\n          \u003ctd\u003eMechanical Fluid Pressure Controller Switch\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eOutput Contact Style\u003c\/td\u003e\n          \u003ctd\u003eSingle Pole Double Throw (SPDT) Snap-action Microswitch\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eElectrical Rating Standard\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eMaximum Steering Control Load\u003c\/td\u003e\n          \u003ctd\u003eHeavy-duty industrial pilot duty compatible (Supports standard AC control lines)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003ePressure Media Group\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eFluid Compatibility Matrix\u003c\/td\u003e\n          \u003ctd\u003eNon-corrosive hydraulic fluids, mineral oils, water, and compressed air loops\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eMechanical Pressure Port\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eFitting Geometry Interface\u003c\/td\u003e\n          \u003ctd\u003eStandard industrial threaded pressure connection flare mapping\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eEnclosure Protection Class\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eEnvironmental Ingress Rating\u003c\/td\u003e\n          \u003ctd\u003eIP65 Equivalent Dust-tight \u0026amp; Splash-resistant when fully coupled\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eAdjustability Architecture\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eField Tuning Interface\u003c\/td\u003e\n          \u003ctd\u003eInternal\/External mechanical set-screw deadband adjustment configuration\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- SECTION 4: Application Matrix --\u003e\n  \u003ch2\u003eApplication Matrix\u003c\/h2\u003e\n  \u003cdiv class=\"koeed-table-responsive\"\u003e\n    \u003ctable class=\"koeed-table\"\u003e\n      \u003cthead\u003e\n        \u003ctr\u003e\n          \u003cth\u003eTarget Industrial System\u003c\/th\u003e\n          \u003cth\u003eDeployment Purpose\u003c\/th\u003e\n          \u003cth\u003eEngineering Value Delivered\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eHydraulic Power Units (HPU)\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eAccumulator pressure maintenance\u003c\/td\u003e\n          \u003ctd\u003eControls the main charging cycle by cutting out the motor driver instantly when peak accumulation bounds are reached.\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eIndustrial Air Compressors\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eReceiver tank limit shielding\u003c\/td\u003e\n          \u003ctd\u003eActs as a fail-safe mechanical high limit circuit breaker to prevent high-pressure structural ruptures or tank structural degradation.\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eAutomated Lubrication Networks\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eLine continuity monitoring\u003c\/td\u003e\n          \u003ctd\u003eTracks instantaneous pressure losses across long pipe configurations, flagging immediate leakage errors to stop machine tool binding.\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- SECTION 5: Koeed B2B Interactive Tool --\u003e\n  \u003ch2\u003eKoeed B2B Tool: Hydraulic Deadband \u0026amp; Pressure Loop Calibrator\u003c\/h2\u003e\n  \u003cp\u003eField technicians must verify how pressure adjustments impact the system deadband (differential) to optimize pump cycling and ensure control circuit currents do not overload the switch mechanism. Use this technical utility to compute loop metrics.\u003c\/p\u003e\n  \n  \u003cdiv class=\"koeed-tool-container\"\u003e\n    \u003cdiv class=\"koeed-tool-grid\"\u003e\n      \u003cdiv class=\"koeed-input-group\"\u003e\n        \u003clabel for=\"koeed-unit-select\"\u003ePressure Metrics System:\u003c\/label\u003e\n        \u003cselect id=\"koeed-unit-select\" onchange=\"koeedUpdatePressureUnits()\"\u003e\n          \u003coption value=\"bar\" selected\u003ebar (Metric Standard)\u003c\/option\u003e\n          \u003coption value=\"psi\"\u003ePSI (Imperial Standard)\u003c\/option\u003e\n          \u003coption value=\"mpa\"\u003eMPa (High Pressure SI)\u003c\/option\u003e\n        \u003c\/select\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"koeed-input-group\"\u003e\n        \u003clabel for=\"koeed-cut-in\" id=\"koeed-lbl-cut-in\"\u003eTarget Cut-in Point (bar):\u003c\/label\u003e\n        \u003cinput type=\"number\" id=\"koeed-cut-in\" value=\"10.0\" step=\"0.5\" oninput=\"koeedCalculateDeadband()\"\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"koeed-input-group\"\u003e\n        \u003clabel for=\"koeed-cut-out\" id=\"koeed-lbl-cut-out\"\u003eTarget Cut-out Point (bar):\u003c\/label\u003e\n        \u003cinput type=\"number\" id=\"koeed-cut-out\" value=\"12.5\" step=\"0.5\" oninput=\"koeedCalculateDeadband()\"\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n    \n    \u003cdiv class=\"koeed-result-panel\"\u003e\n      \u003cdiv class=\"koeed-result-value\" id=\"koeed-deadband-output\"\u003eCalculated Deadband \/ Differential: 2.50 bar\u003c\/div\u003e\n      \u003cdiv style=\"font-size: 0.9em; font-weight: 600; color: #333333;\" id=\"koeed-cycle-note\"\u003eSystem Tuning Status: Stable Hysteresis Slope Managed\u003c\/div\u003e\n      \u003cdiv style=\"margin-top: 8px; font-size: 0.85em; color: #666666;\" id=\"koeed-tool-advice\"\u003eEnsure the differential is large enough to prevent short-cycling of the driving motor under full fluid velocity.\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cnoscript\u003e\n    \u003cdiv class=\"koeed-quote\"\u003e\n      \u003cstrong\u003eEngineering Baseline Operation Guide:\u003c\/strong\u003e The Kompass APSD-40-1 pressure switch requires a strict verification of mechanical differential hysteresis (the gap between cut-in and cut-out configurations) during installation. Maintaining a minimum 10% pressure gap is critical to block high-frequency micro-switching contact failure.\n    \u003c\/div\u003e\n  \u003c\/noscript\u003e\n\n  \u003cscript\u003e\n    function koeedUpdatePressureUnits() {\n      var unit = document.getElementById('koeed-unit-select').value;\n      var lblIn = document.getElementById('koeed-lbl-cut-in');\n      var lblOut = document.getElementById('koeed-lbl-cut-out');\n      var valIn = document.getElementById('koeed-cut-in');\n      var valOut = document.getElementById('koeed-cut-out');\n      \n      if (unit === \"bar\") {\n        lblIn.innerText = \"Target Cut-in Point (bar):\";\n        lblOut.innerText = \"Target Cut-out Point (bar):\";\n        valIn.step = \"0.5\"; valOut.step = \"0.5\";\n      } else if (unit === \"psi\") {\n        lblIn.innerText = \"Target Cut-in Point (PSI):\";\n        lblOut.innerText = \"Target Cut-out Point (PSI):\";\n        valIn.step = \"5\"; valOut.step = \"5\";\n      } else {\n        lblIn.innerText = \"Target Cut-in Point (MPa):\";\n        lblOut.innerText = \"Target Cut-out Point (MPa):\";\n        valIn.step = \"0.05\"; valOut.step = \"0.05\";\n      }\n      koeedCalculateDeadband();\n    }\n\n    function koeedCalculateDeadband() {\n      var unit = document.getElementById('koeed-unit-select').value;\n      var cutIn = parseFloat(document.getElementById('koeed-cut-in').value);\n      var cutOut = parseFloat(document.getElementById('koeed-cut-out').value);\n      \n      if (isNaN(cutIn) || isNaN(cutOut) || cutIn \u003c 0 || cutOut \u003c 0) {\n        return;\n      }\n      \n      var diff = cutOut - cutIn;\n      var isReverse = false;\n      \n      if (diff \u003c 0) {\n        diff = Math.abs(diff);\n        isReverse = true;\n      }\n      \n      document.getElementById('koeed-deadband-output').innerText = \"Calculated Deadband \/ Differential: \" + diff.toFixed(2) + \" \" + unit;\n      \n      var cycleEl = document.getElementById('koeed-cycle-note');\n      var adviceEl = document.getElementById('koeed-tool-advice');\n      var pctOfMax = (diff \/ (cutOut === 0 ? 1 : cutOut)) * 100;\n      \n      if (diff === 0) {\n        cycleEl.innerHTML = \"\u003cspan style='color:#d9534f; font-weight:700;'\u003eCRITICAL RISK: Zero Hysteresis\u003c\/span\u003e\";\n        adviceEl.innerText = \"Nuisance contact chattering will instantly occur, burning out microswitch copper contacts. Increase the differential setting immediately.\";\n      } else if (isReverse) {\n        cycleEl.innerText = \"Configured for Low-Pressure Cut-out \/ Falling Execution Mode\";\n        adviceEl.innerText = \"Ensure your wiring paths align correctly with NC\/NO pins depending on whether the switch should close or open on pressure drop.\";\n      } else if (pctOfMax \u003c 8) {\n        cycleEl.innerHTML = \"\u003cspan style='color:#f0ad4e; font-weight:700;'\u003eWARNING: Tight Differential Hysteresis Matrix\u003c\/span\u003e\";\n        adviceEl.innerText = \"A narrow differential risks rapid motor cycling if line pressure drops quickly. Consider integrating a fluid dampening orifice or hydraulic accumulator.\";\n      } else {\n        cycleEl.innerText = \"System Tuning Status: Stable Hysteresis Slope Managed\";\n        adviceEl.innerText = \"Optimal setting configuration for typical industrial pump stations and machinery safety loops.\";\n      }\n    }\n  \u003c\/script\u003e\n\n  \u003c!-- SECTION 6: Troubleshooting \u0026 FAQ --\u003e\n  \u003ch2\u003eTroubleshooting \u0026amp; FAQ\u003c\/h2\u003e\n  \n  \u003ch3\u003eQ1: What root variables cause continuous contact chattering or buzzing on the Kompass APSD-40-1 switch?\u003c\/h3\u003e\n  \u003cp\u003eContact buzzing or high-frequency cycling typically stems from zero or overly tight mechanical differential configurations, or high-amplitude fluid pulsations inside the intake port lines. If your system lacks a pressure dampening cushion, rapid pressure ripples will force the snap-action bellows to oscillate across its trigger limits. To resolve this, increase the set-screw differential gap slightly or mount a specialized **snubber \/ capillary line expansion loop** prior to the switch entry port to absorb system ripples.\u003c\/p\u003e\n\n  \u003ch3\u003eQ2: How do field technicians correctly map electrical connections across the internal SPDT contact blocks?\u003c\/h3\u003e\n  \u003cp\u003eIsolate the industrial panel power completely before opening the device enclosure head. Utilize a digital multimeter configured for direct audio continuity tracking. Probe the primary common node terminal (COM) against the remaining auxiliary lugs: the **Normally Closed (NC)** contact loop path will maintain solid electrical continuity when the gauge line sits at zero pressure, dropping out immediately once line metrics climb past the target trigger set-point.\u003c\/p\u003e\n\n  \u003ch3\u003eQ3: What methods should be utilized to diagnose sudden execution drift over millions of operating cycles?\u003c\/h3\u003e\n  \u003cp\u003eExtended operational drift typically points to heavy mechanical fatigue across internal counter-acting coil springs, or a buildup of heavy hydraulic varnish and chemical lacquers inside the sensing bellows orifice. Periodically clear out internal port pathways with residue-free electronic solvents, and run validation tracking against a high-precision calibrated analog master test gauge to adjust the set-screws back to nominal specifications.\u003c\/p\u003e\n\n  \u003c!-- SECTION 7: Cross-Reference \u0026 Selection Guide --\u003e\n  \u003ch3\u003eCross-Reference Guide\u003c\/h3\u003e\n  \u003cp\u003eWhen updating automation engineering files, mapping plant system components, or arranging replacement safety hardware stock, evaluate the following selection facts:\u003c\/p\u003e\n  \u003cul class=\"koeed-list\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirect Brand Compatibility:\u003c\/strong\u003e Drop-in dimensional interchangeability for systems built around standard Kompass APSD modular series fluid controllers, matching mounting bracket threads.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUniversal Field Equivalents:\u003c\/strong\u003e Direct physical functional correlation with premium heavy-duty adjustable pressure switches from top global low-voltage control brands like Danfoss (KPI series parameters), Barksdale, and United Electric, provided nominal working pressure zones, current capacity bounds, and physical terminal assignments are correctly matched within the main control blueprint.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Structured JSON-LD Data for AI Scraping Engines --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@graph\": [\n    {\n      \"@type\": \"FAQPage\",\n      \"mainEntity\": [\n        {\n          \"@type\": \"Question\",\n          \"name\": \"What root variables cause continuous contact chattering or buzzing on the Kompass APSD-40-1 switch?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Contact chattering stems from a tight mechanical differential configuration or unmitigated fluid pulsations inside the intake port. To fix this, open up the differential gap via the set-screws or mount a pressure snubber loop to dampen fluid ripples before entry.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"How do field technicians correctly map electrical connections across the internal SPDT contact blocks?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Isolate power and use a multimeter continuity check. The Normally Closed contact loop path will maintain continuity when pressure rests at zero, opening up instantly when system pressure climbs past the target set-point.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"What methods should be utilized to diagnose sudden execution drift over millions of operating cycles?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Drift is commonly caused by internal spring fatigue or chemical lacquer blockages inside the sensing orifice. Clean the pressure pathways utilizing a residue-free solvent and execute regular tracking cross-checks against a reference test gauge.\"\n          }\n        }\n      ]\n    },\n    {\n      \"@type\": \"WebApplication\",\n      \"name\": \"Hydraulic Deadband \u0026 Pressure Loop Calibrator\",\n      \"applicationCategory\": \"BusinessApplication\",\n      \"operatingSystem\": \"All\",\n      \"browserRequirements\": \"Requires HTML5 rendering capabilities. JavaScript tracking must be active.\",\n      \"description\": \"An interactive calculation application designed for low-voltage fluid power engineers to compute mechanical differential values, evaluate hysteresis performance, and prevent contact chattering.\"\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"KOPPAR","offers":[{"title":"Default Title","offer_id":44256773865657,"sku":"166367800414","price":550.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0268\/8476\/7929\/files\/s-l1600_8f72cac5-dbf4-49b3-af2c-90fcf4ed7c22.png?v=1723749119","url":"https:\/\/koeed.com\/no\/products\/new-kompass-apsd-40-1-pressure-switch","provider":"KOEED","version":"1.0","type":"link"}