Mitsubishi FX3U-FLROM-64L Flash Memory Cassette: Complete Guide for PLC Program Storage

Mitsubishi FX3U-FLROM-64L Flash Memory Cassette: Complete Guide for PLC Program Storage

Mitsubishi FX3U-FLROM-64L Flash Memory Cassette

High-capacity 64K-step flash memory solution for FX3U and FX3UC series PLCs with advanced loader functionality

FX3U-FLROM-64L Front View
FX3U-FLROM-64L Side View
FX3U-FLROM-64L Installation View
FX3U-FLROM-64L Close-up
FX3U-FLROM-64L Technical Details
FX3U-FLROM-64L Package Contents
FX3U-FLROM-64L Dimensions

Product Demonstration Video

Product Overview

The Mitsubishi FX3U-FLROM-64L is a high-performance flash memory cassette designed specifically for the MELSEC-F series FX3U and FX3UC programmable logic controllers. This advanced memory module provides 64,000 steps of program storage capacity with built-in loader functionality, making it an essential component for industrial automation systems requiring reliable, non-volatile program storage.

Key Advantage: The FX3U-FLROM-64L eliminates the need for battery backup while providing superior data retention and program protection capabilities, making it ideal for applications where long-term reliability is critical.

Technical Specifications

Specification Details
Product Model FX3U-FLROM-64L
Memory Capacity 64,000 steps (Program)
Compatible PLC Series FX3U, FX3UC
Memory Type Flash ROM with loader function
Battery Backup Required No
Write Protection Protection switch to prevent accidental writing
Writing Method Direct writing with PLC possible
Data Retention Non-volatile flash memory
Copy Function Included

Core Features and Benefits

1. Advanced Loader Functionality

The built-in loader function allows direct program writing from the PLC to the flash memory, eliminating the need for external programming devices in many scenarios. This feature significantly reduces programming time and simplifies maintenance operations.

2. Battery-Free Operation

Unlike traditional RAM-based memory cassettes, the FX3U-FLROM-64L utilizes flash memory technology that doesn't require battery backup. This eliminates battery replacement costs and prevents data loss due to battery failure.

3. Write Protection Switch

A physical protection switch prevents accidental program overwrites, ensuring program integrity in critical industrial environments. This is particularly valuable in applications where unauthorized program modifications could cause safety hazards or production downtime.

4. High-Capacity Storage

With 64,000 steps of program capacity, this memory cassette supports complex automation programs, making it suitable for sophisticated control applications in manufacturing, process control, and building automation.

Applications and Use Cases

Industrial Manufacturing

The FX3U-FLROM-64L is ideal for production lines, assembly systems, and robotic control applications where reliable program storage is essential for continuous operation.

Process Control Systems

In chemical plants, water treatment facilities, and food processing operations, the non-volatile memory ensures program retention during power outages and maintenance cycles.

Building Automation

For HVAC control, lighting systems, and security applications, the memory cassette provides reliable storage for complex control algorithms and scheduling programs.

Equipment OEM Applications

Original equipment manufacturers can use the FX3U-FLROM-64L to store proprietary control programs securely, with protection against unauthorized copying or modification.

Installation and Configuration

The FX3U-FLROM-64L installs directly into the memory cassette slot of compatible FX3U and FX3UC PLCs. Installation is straightforward:

  1. Power down the PLC system
  2. Insert the memory cassette into the designated slot
  3. Set the write protection switch as needed
  4. Power up the system and configure through programming software

Frequently Asked Questions (FAQ)

Q: What is the main advantage of using FX3U-FLROM-64L over standard memory?

A: The primary advantage is the elimination of battery backup requirements combined with non-volatile flash memory technology, ensuring data retention without maintenance concerns.

Q: Can I write programs directly from the PLC to this memory cassette?

A: Yes, the FX3U-FLROM-64L features a built-in loader function that allows direct program writing from the PLC, eliminating the need for external programming devices in many cases.

Q: Is the memory content protected against accidental erasure?

A: Yes, the module includes a physical write protection switch that prevents accidental program overwrites, ensuring program integrity in critical applications.

Q: What PLC models are compatible with FX3U-FLROM-64L?

A: This memory cassette is specifically designed for Mitsubishi MELSEC-F series FX3U and FX3UC programmable controllers.

Q: How does the copy function work?

A: The copy function allows you to duplicate programs between memory cassettes or backup programs to external storage, facilitating program distribution and backup procedures.

Comparison with Other Memory Options

Feature FX3U-FLROM-64L Standard RAM Cassette EEPROM Cassette
Battery Required No Yes No
Write Cycles High (Flash) Unlimited Limited
Data Retention 10+ years With battery 10+ years
Loader Function Yes No Limited
Write Protection Physical switch Software only Software only

Industry Recognition and Trust Metrics

The Mitsubishi FX3U-FLROM-64L is widely recognized in the industrial automation industry for its reliability and performance. According to Mitsubishi Electric's official specifications, this memory cassette has been deployed in thousands of industrial applications worldwide, with proven reliability in demanding environments.

External References:

Ready to Upgrade Your PLC Memory Solution?

Enhance your industrial automation system with the reliable, battery-free memory storage of the Mitsubishi FX3U-FLROM-64L. Get genuine Mitsubishi products with full manufacturer warranty and technical support.

Purchase FX3U-FLROM-64L Now

Visit our official product page at https://koeed.com/products/fx3u-flrom-64l for detailed specifications, pricing, and availability.

Maintenance and Support

The FX3U-FLROM-64L requires minimal maintenance due to its solid-state flash memory design. For optimal performance:

  • Regularly verify program integrity through checksum verification
  • Keep the write protection switch engaged when not actively programming
  • Store backup copies of critical programs in multiple locations
  • Follow Mitsubishi's recommended environmental specifications for temperature and humidity

For technical support and additional product information, visit our comprehensive product page at https://koeed.com/products/fx3u-flrom-64l where you'll find detailed documentation, application notes, and customer support resources.

Related Articles