{"product_id":"sprecher-schuh-ca7-60-00-240-contactor","title":"SPRECHER \u0026 SCHUH CA7-60-00-240","description":"\u003ch1 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:28px; line-height:36px; margin:0 0 8px 0;\"\u003eSprecher + Schuh CA7-60-00-240 IEC Contactor — 60A, 3-Pole, 240V AC Coil\u003c\/h1\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#0056B3; font-size:14px; line-height:22px; letter-spacing:1px; text-transform:uppercase; margin:0 0 24px 0;\"\u003eSprecher+Schuh · CA7 Series · 3-Pole Contactor · In stock\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:0 0 16px 0;\"\u003eThe \u003cstrong\u003eSprecher + Schuh CA7-60-00-240\u003c\/strong\u003e is an IEC-rated, 3-pole AC contactor from the \u003ca href=\"\/pl\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e-aligned CA7 family (Sprecher+Schuh is now a Rockwell Automation brand). With a 60 A AC-3 motor rating, 30 kW @ 400 V, three normally-open main poles, no built-in auxiliary contacts, and a 240 V AC operating coil, the CA7-60-00-240 is engineered for motor control circuits inside \u003ca href=\"\/pl\/collections\/factory-automation\" style=\"color:#0056B3; text-decoration:underline;\"\u003efactory automation\u003c\/a\u003e panels, motor control centers (MCCs), and industrial control equipment. It pairs directly with the CEP7 or CT7 thermal overload relay for full motor protection and is interchangeable with the CA7-60-00 base plus the standard 240 V AC coil code.\u003c\/p\u003e\n\n\u003c!-- ============ Section 1: Key Technical Specifications \/ Overview ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003eKey Technical Specifications \u0026amp; Overview\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #eeeeee; font-family:Arial, Helvetica, sans-serif; font-size:14px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eSprecher + Schuh (Rockwell Automation)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eCA7 (IEC industrial contactor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003ePart Number\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eCA7-60-00-240\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eModule Type\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e3-Pole IEC AC Contactor (motor switching)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eMain Poles\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e3 NO (the \"60-00\" suffix: 60 A frame, 0 auxiliary, 0 side-mount aux)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eAuxiliary Contacts\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eNone built in (field-addable CA7-PA front-mount or CA7-PB side-mount blocks)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eCoil Voltage\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e240 V AC, 50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eAC-3 Motor Rating\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e60 A (approx. 30 kW @ 400 V \/ 50 hp @ 460 V)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eAC-1 Thermal Current (Ith)\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e100 A (resistive \/ non-motor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eMechanical Life\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e10 million operations\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eElectrical Life (AC-3)\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e1 million operations at rated load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eMounting\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e35 mm DIN rail or panel-mount screws (4 x M4)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eTerminals\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eLug terminals; main pole screws M6 box \/ saddle\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eStandards\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eIEC\/EN 60947-1, IEC\/EN 60947-4-1, UL 508, CSA C22.2 No. 14\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003ePairs With\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eSprecher+Schuh CEP7-60 \/ CT7-60 thermal overload relay\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eStock Status\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eIn stock — quote within 24 hours at \u003ca href=\"mailto:Moritta@KOEED.COM\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:16px 0 0 0;\"\u003eThe CA7-60-00-240 is a frame-size 60 contactor in the CA7 family — the same compact, modular platform used widely in \u003ca href=\"\/pl\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e SIRIUS-adjacent panels, \u003ca href=\"\/pl\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e TeSys D \/ LC1D comparable builds, and \u003ca href=\"\/pl\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e S-N series cabinets. Because the Sprecher+Schuh brand is preserved under Rockwell, the CA7-60-00-240 fits the same panel cutout, footprint, and accessory rail as a like-sized \u003ca href=\"\/pl\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e 100-C contactor for engineers standardising on Logix-driven motor starters.\u003c\/p\u003e\n\n\u003c!-- ============ Section 2: Application Scenarios \/ Where It Fits ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003eApplication Scenarios \u0026amp; Where It Fits\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003eThe CA7-60-00-240 is sized for direct-on-line (DOL) motor starting of three-phase induction motors up to approximately 30 kW @ 400 V \/ 50 hp @ 460 V. In real-world industrial settings it is commonly specified for:\u003c\/p\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePumps and water\/wastewater systems\u003c\/strong\u003e — booster pumps, circulation pumps, irrigation pump starters in MCC cubicles.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFans and HVAC\u003c\/strong\u003e — supply \/ exhaust fans, AHU fan starters, cooling tower fans, industrial chiller compressor feeders.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompressors\u003c\/strong\u003e — screw and piston air compressors, refrigerant compressor contactor duty.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConveyors and material handling\u003c\/strong\u003e — belt conveyors, roller conveyors, palletisers, packaging line drives.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMixers, agitators, and process equipment\u003c\/strong\u003e — food \u0026amp; beverage mixers, paint and chemical agitators, dosing skids.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMachine tool auxiliaries\u003c\/strong\u003e — coolant pumps, hydraulic power units, chip conveyor starters, alongside \u003ca href=\"\/pl\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e CNC and \u003ca href=\"\/pl\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e Σ-7 \/ Σ-V servo sections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGeneral industrial control panels\u003c\/strong\u003e — skid-mounted MCCs, OEM machine builders, and brownfield retrofits of older \u003ca href=\"\/pl\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e or \u003ca href=\"\/pl\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic\u003c\/a\u003e motor starters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVision and inspection cells\u003c\/strong\u003e — line-stop \/ E-stop switching of upstream conveyors feeding \u003ca href=\"\/pl\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e CV-5000 \/ XG-8000 inspection stations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:16px 0 0 0;\"\u003eBecause the CA7 family shares its 45 mm frame footprint with adjacent ratings, panel builders can mix the CA7-30, CA7-40, CA7-60, and CA7-85 in a single lineup — useful when a project mixes small \u003ca href=\"\/pl\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e FR-E700 inverter-driven loads with larger DOL pumps in the same MCC.\u003c\/p\u003e\n\n\u003c!-- ============ Section 3: Integration \u0026 Wiring Notes ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003eIntegration \u0026amp; Wiring Notes\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003eWiring the CA7-60-00-240 follows the conventional IEC contactor pattern: three-phase line in on terminals L1 \/ L2 \/ L3, three-phase load out on T1 \/ T2 \/ T3 to the motor, control voltage applied to the A1 \/ A2 coil terminals. The 240 V AC coil code is the most common in 230 V European and 240 V export panels.\u003c\/p\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #eeeeee; font-family:Arial, Helvetica, sans-serif; font-size:14px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background-color:#0056B3; color:#ffffff; padding:12px 16px; text-align:left; border:1px solid #eeeeee; font-weight:bold;\"\u003eTerminal\u003c\/th\u003e\n      \u003cth style=\"background-color:#0056B3; color:#ffffff; padding:12px 16px; text-align:left; border:1px solid #eeeeee; font-weight:bold;\"\u003eFunction\u003c\/th\u003e\n      \u003cth style=\"background-color:#0056B3; color:#ffffff; padding:12px 16px; text-align:left; border:1px solid #eeeeee; font-weight:bold;\"\u003eNotes\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color:#f4fcfc;\"\u003e\n      \u003ctd style=\"padding:10px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eL1 \/ L2 \/ L3\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eLine-side power input\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eFrom upstream breaker or fuse disconnect\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#fafafa;\"\u003e\n      \u003ctd style=\"padding:10px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eT1 \/ T2 \/ T3\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eLoad-side to motor\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eVia CEP7 \/ CT7 thermal overload relay output\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#f4fcfc;\"\u003e\n      \u003ctd style=\"padding:10px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eA1 \/ A2\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e240 V AC coil terminals\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eDriven by PLC DO, control relay, or HOA switch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#fafafa;\"\u003e\n      \u003ctd style=\"padding:10px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eAux block (front or side)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eNO \/ NC status feedback\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eField-add CA7-PA \/ CA7-PB if PLC status readback is needed\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:16px 0 0 0;\"\u003eFor system integration, the coil is typically driven by a 24 V DC control relay or a PLC discrete output — on an \u003ca href=\"\/pl\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e CompactLogix or ControlLogix DO module, a \u003ca href=\"\/pl\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e SIMATIC S7-1200 \/ S7-1500 DQ board, a \u003ca href=\"\/pl\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e MELSEC iQ-R Y-output, or an \u003ca href=\"\/pl\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e CP1E \/ CJ2 transistor output. For applications that require status feedback into the PLC, the CA7-60-00-240 accepts CA7-PA (front-mount) or CA7-PB (side-mount) auxiliary blocks — the \"-00\" code means \u003cem\u003enone are fitted at the factory\u003c\/em\u003e, so order the aux block separately if your logic needs a \"contactor closed\" confirmation bit. The auxiliary contact ratings (typically AC-15 1 A @ 230 V) are sufficient for direct PLC DI wiring without an interposing relay.\u003c\/p\u003e\n\n\u003c!-- ============ Section 4: Installation \u0026 Commissioning Tips ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003eInstallation \u0026amp; Commissioning Tips\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003eField engineers usually bring a CA7-60-00-240 panel up in five steps. Use the checklist below to shorten commissioning and avoid the classic wiring and overload errors.\u003c\/p\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVerify the coil code before energising.\u003c\/strong\u003e \"240\" in the suffix is 240 V AC, 50\/60 Hz. Applying 120 V AC or 24 V DC to a 240 V coil will chatter or fail to pull in; applying 480 V will burn the coil in seconds.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSet the thermal overload current.\u003c\/strong\u003e Match the CEP7-60 or CT7-60 dial to the motor nameplate full-load amps (FLA), not the contactor rating. A 60 A contactor can still feed a 5 A motor — the relay protects the motor, not the contactor.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque the main pole lugs.\u003c\/strong\u003e The M6 box \/ saddle terminals on the CA7-60 frame are typically torqued to around 4 N·m. Loose lugs are the number-one cause of contactor failure under AC-3 duty.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfirm DIN-rail latch or screw-down.\u003c\/strong\u003e The CA7-60 base has a single DIN-rail latch; for high-vibration MCCs (compressors, hydraulic skids) add the two panel-mount screws for a vibration-resistant install.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTest the auxiliary interlock logic.\u003c\/strong\u003e If you have added a CA7-PA \/ CA7-PB block, verify the NO \/ NC mapping against the PLC input mapping table before live load — a swapped aux contact is a common cause of \"contactor won't start\" troubleshooting tickets.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePlan for cross-reference.\u003c\/strong\u003e In mixed-brand cabinets it is normal to pair a CA7-60-00-240 with a TeSys D LC1D80 (\u003ca href=\"\/pl\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e) or S-N80 (\u003ca href=\"\/pl\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e) as a substitute; the panel cutout and DIN-rail footprint are compatible. Check our \u003ca href=\"\/pl\/pages\/real-time-sales-list\" style=\"color:#0056B3; text-decoration:underline;\"\u003ereal-time sales list\u003c\/a\u003e for confirmed cross-references we have shipped.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:16px 0 0 0;\"\u003eFor first-time commissioning, hold the start command on for at least 100 ms so the AC coil pulls in cleanly, and listen for the characteristic \"click\" — a weak pull-in on a 240 V coil often points to a low control-voltage drop across long wire runs rather than a defective contactor.\u003c\/p\u003e\n\n\u003c!-- ============ Section 5: Procurement, Warranty \u0026 Lead Time ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003eProcurement, Warranty \u0026amp; Lead Time\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003eKOEED sources the \u003cstrong\u003eSprecher + Schuh CA7-60-00-240\u003c\/strong\u003e as part of our multi-brand industrial automation portfolio, alongside \u003ca href=\"\/pl\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e 100-C contactors, \u003ca href=\"\/pl\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e SIRIUS 3RT, \u003ca href=\"\/pl\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e S-N \/ SD-N, \u003ca href=\"\/pl\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e J7KC, \u003ca href=\"\/pl\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e A06B modules, \u003ca href=\"\/pl\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e TeSys D, \u003ca href=\"\/pl\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e servo and controller sections, \u003ca href=\"\/pl\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic\u003c\/a\u003e FP PLCs, and \u003ca href=\"\/pl\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e vision systems. The CA7-60-00-240 is a stock SKU — in production volumes it ships inside our standard 24-hour quote and DHL \/ FedEx \/ UPS worldwide shipping window.\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003eFor B2B procurement, send your BOM to \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Sprecher%20Schuh%20CA7-60-00-240\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e with the part number, quantity, and target country; you will receive a quotation including availability, lead time, and freight options within 24 hours on business days. For full panel builds that mix contactors, overload relays, circuit breakers, PLCs, and HMIs, the \u003ca href=\"\/pl\/pages\/request-for-quote\" style=\"color:#0056B3; text-decoration:underline;\"\u003eCreate a Quote\u003c\/a\u003e form accepts multi-line BOMs and is the fastest way to get a consolidated quotation. For questions on coil voltage, aux block selection, or cross-referencing the CA7-60-00-240 against a TeSys D or 100-C equivalent, our engineering team replies directly from \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Sprecher%20Schuh%20CA7-60-00-240\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 12px 0;\"\u003eAll CA7 series contactors we ship are inspected, tested for coil continuity and contact operation, and backed by KOEED's standard warranty. Worldwide shipping is available with full export documentation, including commercial invoice, packing list, and certificates of conformity on request. Need a hard-to-find coil voltage (24 V DC, 110 V AC, 480 V AC) or the \"-01\" \/ \"-10\" aux-code variants? \u003ca href=\"\/pl\/collections\" style=\"color:#0056B3; text-decoration:underline;\"\u003eBrowse the full KOEED collection\u003c\/a\u003e or email your part list to \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Sprecher%20Schuh%20CA7-60-00-240\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e — we routinely source CA7 coils that are out of stock at the local distributor.\u003c\/p\u003e\n\n\u003c!-- ============ Main CTA: BOM Quote ============ --\u003e\n\u003cdiv style=\"background-color:#16c8c8; padding:24px 32px; margin:32px 0; text-align:center; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003ch3 style=\"margin:0 0 12px 0; color:#ffffff; font-size:20px; line-height:28px;\"\u003eNeed this contactor or a full motor-starter BOM?\u003c\/h3\u003e\n  \u003cp style=\"margin:0 0 16px 0; color:#ffffff; font-size:15px; line-height:22px;\"\u003eSend your part list to \u003cstrong\u003eMoritta@KOEED.COM\u003c\/strong\u003e and get availability + price within 24 hours.\u003c\/p\u003e\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Sprecher%20Schuh%20CA7-60-00-240\" style=\"display:inline-block; background-color:#ffffff; color:#0056B3; padding:12px 24px; text-decoration:none; font-weight:bold; border-radius:4px; font-size:15px;\"\u003eRequest a Quote →\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- ============ Secondary CTA: Browse same series ============ --\u003e\n\u003cdiv style=\"border:1px solid #0056B3; padding:16px 24px; margin:16px 0; text-align:left; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 8px 0; color:#111111; font-size:15px; line-height:22px;\"\u003eLooking for more in the CA7 \/ Sprecher+Schuh family or motor-control accessories?\u003c\/p\u003e\n  \u003ca href=\"\/pl\/collections\" style=\"display:inline-block; color:#0056B3; padding:6px 18px; text-decoration:none; font-weight:bold; border:1px solid #0056B3; border-radius:4px; font-size:14px;\"\u003eBrowse all KOEED collections →\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- ============ Tertiary CTA: Engineer tools ============ --\u003e\n\u003cdiv style=\"border:1px solid #eeeeee; background-color:#f4fcfc; padding:16px 24px; margin:16px 0; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 4px 0; color:#111111; font-size:15px; font-weight:bold;\"\u003e\u0026gt; Need to size a thermal overload or look up an IEC utilisation category?\u003c\/p\u003e\n  \u003cp style=\"margin:0 0 8px 0; color:#333333; font-size:14px;\"\u003eTry the KOEED free online PLC \/ motor-control toolset.\u003c\/p\u003e\n  \u003ca href=\"\/pl\/pages\/ai-tool\" style=\"color:#0056B3; text-decoration:underline; font-weight:bold; font-size:14px;\"\u003eOpen the KOEED AI Diagnostic Tool\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:14px; line-height:22px; margin:24px 0 0 0;\"\u003eRelated links: \u003ca href=\"\/pl\/pages\/about-us\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAbout KOEED\u003c\/a\u003e · \u003ca href=\"\/pl\/pages\/about-china-sourcing-company\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAbout China Sourcing Company\u003c\/a\u003e · \u003ca href=\"\/pl\/pages\/contact-us\" style=\"color:#0056B3; text-decoration:underline;\"\u003eContact Us\u003c\/a\u003e · \u003ca href=\"\/pl\/pages\/faq\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFAQs\u003c\/a\u003e · \u003ca href=\"\/pl\/blogs\/daily-plc-news\" style=\"color:#0056B3; text-decoration:underline;\"\u003eDaily PLC News\u003c\/a\u003e · \u003ca href=\"\/pl\/pages\/brands\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAll Brands\u003c\/a\u003e\u003c\/p\u003e\n","brand":"SPRECHER_SCHUH","offers":[{"title":"Default Title","offer_id":44183261905081,"sku":"314908727556","price":282.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0268\/8476\/7929\/files\/SPRECHER___SCHUH_CA7_60_00_240___SPRECHER_SCHUH__1.webp?v=1774527035","url":"https:\/\/koeed.com\/pl\/products\/sprecher-schuh-ca7-60-00-240-contactor","provider":"KOEED","version":"1.0","type":"link"}