{"product_id":"1pcs-new-for-pan-globe-p909x-301-020-300ax-temperature-controller","title":"PAN-GLOBE P909X-301-020-300AX Temperature Controller – 1PCS New","description":"\u003ch1 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:28px; line-height:36px; margin:0 0 8px 0;\"\u003e\n  Pan-Globe P909X-301-020-300AX Digital PID Temperature Controller\n\u003c\/h1\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#0056B3; font-size:14px; line-height:22px; letter-spacing:1px; text-transform:uppercase; margin:0 0 24px 0;\"\u003e\n  Pan-Globe · P9000 Series · 1\/4 DIN Panel Controller · 300 A External Switching\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:0 0 16px 0;\"\u003e\n  The \u003cstrong\u003ePan-Globe P909X-301-020-300AX\u003c\/strong\u003e is a high-end digital PID temperature controller from\n  \u003ca href=\"\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePan-Globe\u003c\/a\u003e,\n  a Chinese industrial temperature-control OEM, built for tight thermal-loop performance in plastics,\n  packaging, semiconductor, food \u0026amp; beverage, and furnace applications. With a 96 × 96 mm panel\n  cutout, multi-sensor input, dual control output, fuzzy logic plus auto-tuning, and an optional RS-485\n  Modbus RTU port, the P909X covers the same functional ground as controllers from\n  \u003ca href=\"\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e,\n  \u003ca href=\"\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e,\n  \u003ca href=\"\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e, and\n  \u003ca href=\"\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e\n  at a substantially different price point. The “300AX” suffix denotes a 300 A external\n  switching capacity achieved by driving an external SSR or contactor from the controller’s\n  SSR-driver output — not a built-in switch rating.\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:0 0 16px 0;\"\u003e\n  Engineers rebuilding a plastics extruder, retrofitting a packaging line, or specifying a new heat-treatment\n  oven often reach for a Pan-Globe P909X as a cost-effective alternative to\n  \u003ca href=\"\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e,\n  \u003ca href=\"\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e,\n  \u003ca href=\"\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e, and\n  \u003ca href=\"\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e units when\n  the application is thermal-loop, not motion or vision. Browse the wider industrial-automation catalog on\n  the \u003ca href=\"\/collections\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAll collection\u003c\/a\u003e page, or\n  submit a multi-line BOM through\n  \u003ca href=\"\/pages\/request-for-quote\" style=\"color:#0056B3; text-decoration:underline;\"\u003eCreate a Quote\u003c\/a\u003e\n  for a single-sheet RFQ.\n\u003c\/p\u003e\n\n\u003c!-- ============ 1. Key Technical Specifications ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  1. Key Technical Specifications \u0026amp; Overview\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  The P909X-301-020-300AX is the 1\/4 DIN (96 × 96 mm) form-factor variant in the Pan-Globe P9000\n  family, designed to slot into legacy panels originally cut for\n  \u003ca href=\"\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e E5CN\/E5CC, Gefran\n  800, or earlier P9090-series controllers. Its 300 A designation refers to the external load the panel\n  can command through an external solid-state relay or contactor, not to an internal switch rating —\n  always pair it with a properly heat-sinked SSR sized for the actual heater current.\n\u003c\/p\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #eeeeee; font-family:Arial, Helvetica, sans-serif; font-size:14px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003ePan-Globe (Chinese industrial temperature-control OEM)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eP9000 high-end digital PID family\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003ePart Number\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eP909X-301-020-300AX\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eModule Type\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eDigital PID temperature controller (1\/4 DIN panel mount)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003ePanel Cutout\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e96 × 96 mm (1\/4 DIN), ~100 mm depth behind bezel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eDisplay\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eDual 4-digit LED — upper (PV, red), lower (SV, green); status LEDs for output \/ alarm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSupply Voltage\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e100–240 V AC, 50\/60 Hz (24 V DC variant on request)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSensor Input\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eTC (J, K, R, S, B, E, T, N); RTD (Pt100, Cu50); analog (4–20 mA, 0–10 V); user-selectable per channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eControl Output 1 (Main)\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eSSR driver (12 V DC pulse, ~30 mA) OR relay (SPST 250 V AC \/ 5 A); 4–20 mA \/ 0–10 V retransmission on selected suffix\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eControl Output 2 (Aux \/ Alarm)\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eRelay (SPDT 250 V AC \/ 3 A), configurable as alarm or second-stage control\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eExternal Switching Capacity (“300AX”)\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e300 A — via external SSR or contactor driven by controller SSR-driver output\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eControl Algorithm\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003ePID with auto-tune, fuzzy logic overshoot suppression; on-off \/ P \/ PI \/ PD \/ PID modes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eCommunication\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eRS-485 Modbus RTU (suffix-dependent); isolated interface, up to 32 nodes per trunk\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eAlarm Functions\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eDeviation high \/ low, absolute high \/ low, sensor break, heater break (current-sensing option)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eFront-Panel Protection\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eIP65 with supplied gasket; NEMA 4X equivalent for washdown areas\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eOperating Ambient\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e−10 °C to +50 °C, 10–90 % RH non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eApprovals\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eCE \/ RoHS (suffix-dependent); confirm at order time for the exact build\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eStock Status\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        In stock — quote within 24 hours at\n        \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Pan-Globe%20P909X-301-020-300AX\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003c!-- ============ 2. Application Scenarios ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  2. Application Scenarios \u0026amp; Where It Fits\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  The P909X-301-020-300AX is designed for any closed-loop thermal process where the heater load sits well\n  above what a 5 A panel relay can switch directly. Across plastics, packaging, and process plants it\n  is a routine drop-in for engineers who want PID-grade control without the brand-name markup. The\n  \u003ca href=\"\/collections\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAll collection\u003c\/a\u003e index also\n  lists alternative controllers from\n  \u003ca href=\"\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e,\n  \u003ca href=\"\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e, and\n  \u003ca href=\"\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e for projects that\n  require a specific brand standard.\n\u003c\/p\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0; padding-left:24px;\"\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003ePlastics extrusion \u0026amp; injection molding\u003c\/strong\u003e — barrel-zone temperature control; cascade to extruder RPM via a\n    \u003ca href=\"\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e or\n    \u003ca href=\"\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e PLC for synchronized ramp\/soak profiles.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003ePackaging sealing \u0026amp; shrink tunnels\u003c\/strong\u003e — constant-temperature sealing bars, impulse cutoff, and shrink-film oven loops running 24\/7 at high duty cycle.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003eHot-melt glue pots \u0026amp; applicators\u003c\/strong\u003e — narrow-band control around 160–190 °C where PID overshoot protection directly extends heater life.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003eFood \u0026amp; beverage pasteurization and CIP\u003c\/strong\u003e — sanitary washdown areas benefit from the IP65 front bezel; often paired with a\n    \u003ca href=\"\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e Modicon M340 in dairy and beverage lines.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003eHeat-treatment ovens, autoclaves \u0026amp; sterilizers\u003c\/strong\u003e — multi-segment ramp\/soak with deviation alarms to qualify each batch per process spec.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003eSemiconductor wet bench \u0026amp; lab furnaces\u003c\/strong\u003e — tight ±1 °C control for acid-bath temperature and cleanroom furnace profiles.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003eCeramics kilns \u0026amp; glass lehrs\u003c\/strong\u003e — long-time-constant loads where the controller’s fuzzy logic keeps the integrator from winding up during slow ramps.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003eHVAC duct \u0026amp; reheat coil monitoring\u003c\/strong\u003e — paired with a\n    \u003ca href=\"\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e Σ-7 drive or\n    \u003ca href=\"\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e sensor upstream of the heating coil.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003ePharmaceutical stability chambers \u0026amp; incubators\u003c\/strong\u003e — audit-trail-friendly Modbus link to a\n    \u003ca href=\"\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic\u003c\/a\u003e FP7 or Siemens LOGO! for GMP logging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c!-- ============ 3. Integration \u0026 Wiring ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  3. Integration \u0026amp; Wiring Notes\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  Wiring the P909X-301-020-300AX follows the same conventions used by most 1\/4 DIN PID controllers in the\n  \u003ca href=\"\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e E5CN\/E5CC,\n  \u003ca href=\"\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e RWF, and\n  \u003ca href=\"\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e\n  Pixel\/Color PID families. Always confirm the rear-terminal layout against the build-specific datasheet\n  before energizing — the suffix on the P909X part number determines whether the main output is\n  SSR-driver pulse, a 5 A electromechanical relay, or a 4–20 mA \/ 0–10 V analog\n  output.\n\u003c\/p\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #eeeeee; font-family:Arial, Helvetica, sans-serif; font-size:14px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:30%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSensor wiring (TC \/ RTD \/ mA-V)\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eUse shielded twisted-pair; ground the shield at controller end only. For thermocouples, run the correct compensation wire — copper-to-thermocouple-grade — all the way to the terminal. RTDs use 3-wire connection; jumper TB for 2-wire sensors and add a fixed offset in software.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:30%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSSR driver output (main)\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e12 V DC nominal, ~30 mA — drives any standard 3–32 V DC input SSR. Wire the SSR control input to terminals 5\/6; the SSR switches the actual heater load. For 300 A applications, mount the SSR (or a back-to-back pair) on a properly sized heat sink and verify the case temperature at full load.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:30%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eAux relay output (alarm \/ second stage)\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eSPDT, rated 250 V AC \/ 3 A. Configure as deviation-high alarm, sensor-break alarm, or secondary on\/off control loop. Use an interposing contactor when driving loads above 3 A.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:30%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eRS-485 Modbus RTU\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eIsolated RS-485 on selected suffixes; connect A \/ B \/ SG; add 120 Ω termination at the two ends of the trunk. Use shielded twisted-pair and do not run parallel to VFD power cables. The controller is a Modbus slave — set address, baud (9600 \/ 19200), and parity in the configuration menu.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:30%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eHeater sizing for 300AX\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eThe 300AX rating is the external load, not the controller switch rating. Choose an SSR with 1.5–2× the steady-state heater current (e.g. 200 A SSR for a 150 A continuous load) and verify the thermal derating curves from the SSR vendor.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:30%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003ePower \u0026amp; grounding\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e100–240 V AC mains to L \/ N \/ PE; keep the PE conductor short and bonded to the panel chassis. For 24 V DC variants, observe polarity; the supply common is usually tied to the sensor-input common internally.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003c!-- ============ 4. Installation \u0026 Commissioning ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  4. Installation \u0026amp; Commissioning Tips\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  The P909X mounts into a 96 × 96 mm panel cutout with the supplied side clamps tightened against\n  the rear of the cabinet. Use the included rubber gasket to achieve IP65 on the operator face —\n  important in\n  \u003ca href=\"\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e \/\n  washdown areas. Allow at least 100 mm of rear clearance for the terminal block and SSR heat-sink\n  airflow, and avoid routing the SSR-driver output cable next to the TC input cable to keep common-mode\n  noise down. Pre-commissioning checklist:\n\u003c\/p\u003e\n\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0; padding-left:24px;\"\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003eVerify the suffix\u003c\/strong\u003e on the P909X nameplate matches the build on the spec sheet — input type, main output (SSR \/ relay \/ 4–20 mA), and communication option are suffix-driven.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003eConfirm sensor type\u003c\/strong\u003e in the configuration menu before powering the heater; an unconfigured input reads “----” or “Sbr” (sensor break) on first power-up.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003eRun auto-tune\u003c\/strong\u003e at a safe process temperature (typically 50 % of setpoint) with the process empty or the production line idling — the controller performs a controlled bump and calculates P, I, D terms automatically. Stash the resulting values for future replacement skus.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003eSet alarm thresholds\u003c\/strong\u003e for deviation-high and absolute-high; wire the aux relay to a safety interlock, not just a beacon. Most thermal-runaway events are caught by deviation alarms before they are caught by absolute-high.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003eLock the parameter menu\u003c\/strong\u003e with a passcode after commissioning to keep operators from editing SV \/ PID by accident.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003eTest the SSR driver\u003c\/strong\u003e with a bench load (lamp or low-power heater) before connecting the production heater — this catches wiring mistakes and SSR polarity issues without risking a process batch.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003eEnable sensor-break protection\u003c\/strong\u003e — the controller should drop its main output to 0 % when the input is open or shorted, not hold the last output.\u003c\/li\u003e\n  \u003cli style=\"margin:0 0 8px 0;\"\u003e\n\u003cstrong\u003eFor Modbus \/ SCADA integration\u003c\/strong\u003e, map PV, SV, MV (manipulated value), and alarm status to the holding registers listed in the datasheet; the\n    \u003ca href=\"\/pages\/modbus-crc-calculator\" style=\"color:#0056B3; text-decoration:underline;\"\u003eModbus CRC calculator\u003c\/a\u003e\n    on the Tools page helps when building the request frame.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c!-- ============ 5. Procurement, Warranty \u0026 Lead Time ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  5. Procurement, Warranty \u0026amp; Lead Time\n\u003c\/h2\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px; margin:0 0 16px 0;\"\u003e\n  KOEED keeps the Pan-Globe P909X-301-020-300AX in stock as a single-unit new-old-stock SKU (1 PCS,\n  factory-sealed). Pricing follows our standard\n  \u003ca href=\"\/pages\/about-us\" style=\"color:#0056B3; text-decoration:underline;\"\u003eB2B RFQ workflow\u003c\/a\u003e: no\n  public list price, with tiered breaks at 5 \/ 10 \/ 25 \/ 50 pcs. A quote is normally returned within\n  24 hours on business days; a BOM of mixed P909X suffixes, sensors, and SSRs can be submitted on a\n  single sheet via the\n  \u003ca href=\"\/pages\/request-for-quote\" style=\"color:#0056B3; text-decoration:underline;\"\u003eCreate a Quote\u003c\/a\u003e\n  page or sent directly to\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Pan-Globe%20P909X-301-020-300AX\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e.\n\u003c\/p\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #eeeeee; font-family:Arial, Helvetica, sans-serif; font-size:14px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eStock Status\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eIn stock — single-piece and small-quantity orders ship from Hong Kong \/ Shenzhen\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eLead Time\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eIn-stock units: 1–3 business days for air shipment; 5–7 business days for sea; larger BOMs quoted per project\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eWarranty\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e12 months limited warranty on new units — see the \u003ca href=\"\/pages\/return-policy\" style=\"color:#0056B3; text-decoration:underline;\"\u003eReturn Policy\u003c\/a\u003e page for full terms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003ePre-Shipment Test\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e100 % electrical check (input type, output stage, keypad, LED) — bench-tested with a simulated TC \/ RTD source before dispatch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eMinimum Order Quantity\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e1 PCS for sample \/ replacement orders; 5 PCS for tier-1 price break; 25 PCS for project pricing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eWorldwide Shipping\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eDHL \/ FedEx \/ UPS \/ EMS — see the \u003ca href=\"\/pages\/shipping-policy\" style=\"color:#0056B3; text-decoration:underline;\"\u003eShipping Policy\u003c\/a\u003e page for region cut-offs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eQuote \u0026amp; RFQ\u003c\/td\u003e\n      \u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n        Send the BOM to\n        \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Pan-Globe%20P909X-301-020-300AX\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e\n        or use the\n        \u003ca href=\"\/pages\/request-for-quote\" style=\"color:#0056B3; text-decoration:underline;\"\u003eCreate a Quote\u003c\/a\u003e form\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003e24\/7 AI Sourcing\u003c\/td\u003e\n      \u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eFor nameplate-photo identification and end-of-life alternative suggestions, try the \u003ca href=\"\/pages\/ai-tool\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAI Diagnostic Tool\u003c\/a\u003e before sending a manual RFQ\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003c!-- ============ Main CTA ============ --\u003e\n\u003cdiv style=\"background-color:#16c8c8; padding:24px 32px; margin:32px 0; text-align:center; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003ch3 style=\"margin:0 0 12px 0; color:#ffffff; font-size:20px; line-height:28px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Need this controller — or a full cabinet BOM?\n  \u003c\/h3\u003e\n  \u003cp style=\"margin:0 0 16px 0; color:#ffffff; font-size:15px; line-height:22px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Send the P909X part-number suffix, sensor type, and heater load to\n    \u003cstrong\u003eMoritta@KOEED.COM\u003c\/strong\u003e and get availability + a tiered quote within 24 hours.\n  \u003c\/p\u003e\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Pan-Globe%20P909X-301-020-300AX\" style=\"display:inline-block; background-color:#ffffff; color:#0056B3; padding:12px 24px;\n            text-decoration:none; font-weight:bold; border-radius:4px; font-size:15px;\n            font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Request a Quote →\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- ============ Secondary CTA ============ --\u003e\n\u003cdiv style=\"border:1px solid #0056B3; padding:16px 24px; margin:16px 0; text-align:left; font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 8px 0; color:#111111; font-size:15px; line-height:22px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Looking for more in the same family?\n  \u003c\/p\u003e\n  \u003ca href=\"\/collections\/panasonic\" style=\"display:inline-block; color:#0056B3; padding:6px 18px;\n            text-decoration:none; font-weight:bold; border:1px solid #0056B3;\n            border-radius:4px; font-size:14px; font-family:Arial, Helvetica, sans-serif;\"\u003e\n    Browse Pan-Globe \u0026amp; Industrial Controllers →\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#555555; font-size:13px; line-height:20px; margin:24px 0 0 0;\"\u003e\n  Need a datasheet PDF, firmware, or help matching a P909X suffix to your heater load? Email\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20Pan-Globe%20P909X-301-020-300AX\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e\n  and our sourcing team will reply within one business day.\n\u003c\/p\u003e\n\n\u003c!-- ============ Schema.org JSON-LD ============ --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\/\",\n  \"@type\": \"Product\",\n  \"name\": \"Pan-Globe P909X-301-020-300AX Digital PID Temperature Controller\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"Pan-Globe\"\n  },\n  \"category\": \"Digital PID Temperature Controller\",\n  \"sku\": \"P909X-301-020-300AX\",\n  \"mpn\": \"P909X-301-020-300AX\",\n  \"description\": \"1\/4 DIN digital PID temperature controller with multi-sensor input (TC\/RTD\/4-20mA\/0-10V), dual output (SSR driver + relay or 4-20mA + relay), fuzzy logic + auto-tune, RS-485 Modbus RTU option, IP65 front panel, 300 A external switching capacity.\",\n  \"url\": \"\/products\/pan-globe-p909x-301-020-300ax\"\n}\n\u003c\/script\u003e\n","brand":"PANASONIC","offers":[{"title":"Default Title","offer_id":43910088327353,"sku":"304406574497","price":258.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0268\/8476\/7929\/files\/s-l1600_0dbc05fa-8d79-4983-a4ae-27378a10a200.jpg?v=1712761993","url":"https:\/\/koeed.com\/products\/1pcs-new-for-pan-globe-p909x-301-020-300ax-temperature-controller","provider":"KOEED","version":"1.0","type":"link"}