{"product_id":"new-1-pcs-lx-fan-fan-fdb801524h-dc-24v-0-14a-8015-8cm-2-pin","title":"New 1PCS LX-FAN FDB801524H DC24V 0.14A 8015 8CM 2PIN","description":"\u003cdiv class=\"koeed-container\"\u003e\n    \u003c!-- SEO Introduction --\u003e\n    \u003ch2 class=\"koeed-heading\"\u003eLX-FAN FDB801524H DC Cooling Fan (80x80x15mm, 24V)\u003c\/h2\u003e\n    \u003cp\u003eThe \u003cstrong\u003eLX-FAN FDB801524H\u003c\/strong\u003e is a reliable, industrial-grade DC axial cooling fan designed for compact thermal management. Operating at 24V DC with a current draw of 0.14A, this 80mm x 80mm x 15mm (8015 form factor) slim fan is frequently deployed in space-constrained industrial equipment, including Variable Frequency Drives (VFDs), Uninterruptible Power Supplies (UPS), welding machines, and telecom enclosures.\u003c\/p\u003e\n    \u003cp\u003eAt Koeed, we provide high-quality replacement thermal management components to ensure your critical automation hardware does not suffer from thermal throttling or overheat failures. \u003cem\u003eKeywords: LX-FAN FDB801524H, 8015 Cooling Fan, 24V DC Fan, 0.14A Fan, VFD Replacement Fan, 2-Pin Industrial Fan.\u003c\/em\u003e\u003c\/p\u003e\n\n    \u003c!-- Technical Specifications --\u003e\n    \u003ch2 class=\"koeed-heading\"\u003eTechnical Specifications \u0026amp; Performance Data\u003c\/h2\u003e\n    \u003cp\u003e\u003cem\u003eCritical FAE Note: The data below is derived from the model nomenclature and standard electrical formulas. Because this is a 2-Pin unit, it operates at a constant speed determined by the input voltage, without Tachometer (speed sensor) or PWM control signals.\u003c\/em\u003e\u003c\/p\u003e\n    \n    \u003cdiv style=\"overflow-x: auto;\"\u003e\n        \u003ctable class=\"koeed-table\"\u003e\n            \u003cthead\u003e\n                \u003ctr\u003e\n                    \u003cth\u003eSpecification Category\u003c\/th\u003e\n                    \u003cth\u003eDetail \/ Parameter\u003c\/th\u003e\n                \u003c\/tr\u003e\n            \u003c\/thead\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\u003cstrong\u003eManufacturer \/ Brand\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eLX-FAN\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eFDB801524H\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e80 mm x 80 mm x 15 mm (Slim 8015 Profile)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e24V DC (Direct Current)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.14 A\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCalculated Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e3.36 W (Watts)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e2-Pin Connector (Power \u0026amp; Ground only)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\u003cstrong\u003eBearing Technology\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eFluid Dynamic Bearing (FDB) or Ball Bearing \u003cem\u003e(Refer to physical label)\u003c\/em\u003e\n\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\u003cstrong\u003eFrame \u0026amp; Impeller Material\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eIndustrial Thermoplastic (Typically UL94V-0 rated)\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- Application \u0026 Reliability --\u003e\n    \u003ch2 class=\"koeed-heading\"\u003eIndustrial Applications \u0026amp; Thermal Reliability\u003c\/h2\u003e\n    \u003cp\u003eProper thermal dissipation is the lifeline of power electronics. The slim 15mm depth of the \u003cstrong\u003eFDB801524H\u003c\/strong\u003e allows it to fit tightly between heat sinks and enclosure panels in motor drives and control cabinets. As a 2-pin fan, it runs at full RPM when 24V is applied. Regular inspection of the fan blades for dust accumulation and listening for bearing friction are essential preventative maintenance steps to avoid unexpected hardware shutdowns due to elevated internal temperatures.\u003c\/p\u003e\n\n    \u003c!-- Troubleshooting FAQ --\u003e\n    \u003ch2 class=\"koeed-heading\"\u003eTroubleshooting FAQ for 2-Pin Industrial DC Fans\u003c\/h2\u003e\n    \u003cdiv class=\"koeed-faq-section\"\u003e\n        \u003ch3\u003eQ: The new FDB801524H fan has a different connector housing than my old broken fan. How do I install it?\u003c\/h3\u003e\n        \u003cp\u003eA: This is a common scenario in industrial maintenance, as OEMs often use proprietary connectors. Since it is a 2-pin fan, you can safely cut the connector off the old fan (leaving some wire length) and splice it onto the bare wires of the new fan. Ensure strict polarity alignment: typically Red wire to Positive (+) and Black wire to Negative (-). Use heat-shrink tubing to insulate the splices.\u003c\/p\u003e\n        \n        \u003ch3\u003eQ: My VFD is still reporting an \"Overheat\" or \"Fan Fault\" alarm even after replacing this fan. Why?\u003c\/h3\u003e\n        \u003cp\u003eA: If the FDB801524H is spinning properly but the alarm persists, two issues are possible: 1) The heat sink fins beneath the fan are completely blocked by industrial debris, preventing airflow. 2) If the original fan was a 3-pin model (with a tachometer signal wire) and you bypassed it with this 2-pin model, the VFD's logic board is detecting a \"zero RPM\" state and throwing a fault.\u003c\/p\u003e\n        \n        \u003ch3\u003eQ: Can I run this 24V DC fan on a 12V DC power supply?\u003c\/h3\u003e\n        \u003cp\u003eA: Technically, many 24V DC fans will start and spin at 12V, but they will operate at drastically reduced RPMs (roughly half speed) and provide a fraction of their rated airflow (CFM). This will severely compromise the cooling capacity and is not recommended for industrial equipment that requires a 24V thermal solution.\u003c\/p\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- Koeed Custom Styles --\u003e\n\u003cstyle\u003e\n    .koeed-container { width: 100%; font-family: inherit; line-height: 1.6; color: #333; }\n    .koeed-heading { color: #0056b3; border-bottom: 2px solid #16c8c8; padding-bottom: 8px; margin-top: 30px; }\n    .koeed-table { width: 100%; border-collapse: collapse; margin-bottom: 20px; }\n    .koeed-table th, .koeed-table td { border: 1px solid #eeeeee; padding: 12px; text-align: left; }\n    .koeed-table tr:nth-child(even) { background-color: #fafafa; }\n    .koeed-table tr:nth-child(odd) { background-color: #f4fcfc; }\n    .koeed-table th { background-color: #0056b3; color: white; }\n    .koeed-faq-section h3 { color: #333; margin-top: 20px; font-size: 1.1em; }\n    .koeed-faq-section p { margin-top: 5px; color: #555; }\n\u003c\/style\u003e\n\n\u003c!-- JSON-LD Structured Data for SEO --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"The new FDB801524H fan has a different connector housing than my old broken fan. How do I install it?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"You can cut the connector from the old fan and splice it onto the new fan's wires. Ensure correct polarity (Red to Positive, Black to Negative) and insulate with heat-shrink tubing.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"My VFD is still reporting an Overheat or Fan Fault alarm even after replacing this fan. Why?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The heat sink fins might be blocked by debris, preventing airflow. Alternatively, if the original fan was a 3-pin model with a speed sensor, using a 2-pin replacement causes the system to detect a zero RPM state, triggering a fault.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can I run this 24V DC fan on a 12V DC power supply?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"While it may spin, it will operate at drastically reduced RPMs and provide insufficient airflow. It is not recommended for equipment requiring 24V cooling capacity.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"LX","offers":[{"title":"Default Title","offer_id":44534989684921,"sku":"255481078505","price":13.83,"currency_code":"USD","in_stock":true}],"url":"https:\/\/koeed.com\/products\/new-1-pcs-lx-fan-fan-fdb801524h-dc-24v-0-14a-8015-8cm-2-pin","provider":"KOEED","version":"1.0","type":"link"}