{"product_id":"new-allen-bradley-1734-ie4s-1734ie4s-safety-input-module","title":"Allen-Bradley 1734-IE4S Safety Input Module","description":"\u003ch1 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:28px; line-height:36px; margin:0 0 8px 0;\"\u003e\n  Allen-Bradley 1734-IE4S POINT I\/O Safety Input Module\n\u003c\/h1\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#0056B3; font-size:14px; line-height:22px;\n          letter-spacing:1px; text-transform:uppercase; margin:0 0 24px 0;\"\u003e\n  Allen-Bradley · POINT I\/O · 1734-IE4S · 4CH Safety Analog Input · In stock\n\u003c\/p\u003e\n\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:16px; line-height:26px; margin:0 0 16px 0;\"\u003e\n  The \u003cstrong\u003eAllen-Bradley 1734-IE4S\u003c\/strong\u003e is a POINT I\/O safety-rated analog\n  input module with 4 single-ended channels, designed for functional safety\n  applications in\n  \u003ca href=\"\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e\n  CompactLogix and ControlLogix systems. Part of the 1734 POINT I\/O platform, this\n  module enables safety-rated analog signal acquisition — such as emergency stop\n  monitoring, light curtain feedback, and safety-rated pressure\/temperature sensing.\n  KOEED stocks the 1734-IE4S for safety system integrators and maintenance teams,\n  available for\n  \u003ca href=\"\/pages\/request-for-quote\" style=\"color:#0056B3; text-decoration:underline;\"\u003eimmediate quotation\u003c\/a\u003e.\n\u003c\/p\u003e\n\n\u003c!-- ============ Key Specifications ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Key Specifications\n\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #eeeeee;\n              font-family:Arial, Helvetica, sans-serif; font-size:14px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eAllen-Bradley (Rockwell Automation)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e1734-IE4S\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e1734 POINT I\/O — Safety-Rated Analog Input\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eChannels\u003c\/td\u003e\n\u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e4 single-ended analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eSafety Rating\u003c\/td\u003e\n\u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eSIL 2 \/ PL d (functional safety certified)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eCompactLogix (1769-L3x), ControlLogix (1756-L7x) with POINT I\/O adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eStock Status\u003c\/td\u003e\n\u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003eIn stock — quote at \u003ca href=\"mailto:Moritta@KOEED.COM\" style=\"color:#16c8c8; text-decoration:underline; font-weight:bold;\"\u003eMoritta@KOEED.COM\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c!-- ============ Application Scenarios ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Typical Applications\n\u003c\/h2\u003e\n\u003cul style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSafety instrumented systems\u003c\/strong\u003e — SIL-rated analog signal acquisition for emergency shutdown and fire \u0026amp; gas detection in process plants\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMachine safety guarding\u003c\/strong\u003e — safety-rated pressure mat, light curtain, and safety edge monitoring in robotic work cells\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePress and stamping safety\u003c\/strong\u003e — safety analog inputs for tonnage monitoring and die protection in metal forming\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomated guided vehicles (AGV)\u003c\/strong\u003e — safety zone monitoring and collision avoidance sensor integration\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging machinery safety\u003c\/strong\u003e — safety-rated sensor feedback for interlocked guards and light curtains in high-speed packaging lines\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c!-- ============ Related \/ Cross-Reference ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Related Modules \u0026amp; Cross-Reference\n\u003c\/h2\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #eeeeee;\n              font-family:Arial, Helvetica, sans-serif; font-size:14px;\"\u003e\n  \u003ctr\u003e\n\u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003e1734 safety I\/O family\u003c\/td\u003e\n\u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e1734-IB8S (8CH safety digital input), 1734-OB8S (8CH safety digital output) — \u003ca href=\"mailto:Moritta@KOEED.COM\" style=\"color:#0056B3; text-decoration:underline;\"\u003esend BOM\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"width:40%; background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003ePOINT I\/O adapters\u003c\/td\u003e\n\u003ctd style=\"background-color:#fafafa; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e1734-AENT (EtherNet\/IP), 1734-ACNR (ControlNet) — required for module communication\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"width:40%; background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#111111; font-weight:bold;\"\u003eAlternative safety platforms\u003c\/td\u003e\n\u003ctd style=\"background-color:#f4fcfc; padding:12px 16px; border:1px solid #eeeeee; color:#333333;\"\u003e\n\u003ca href=\"\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens ET200SP F\u003c\/a\u003e · \u003ca href=\"\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron NX-SL\u003c\/a\u003e · \u003ca href=\"\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider X80 Safety\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c!-- ============ Why Source from KOEED ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Why Source Safety I\/O Modules from KOEED\n\u003c\/h2\u003e\n\u003cp style=\"font-family:Arial, Helvetica, sans-serif; color:#333333; font-size:15px; line-height:24px;\"\u003e\n  KOEED stocks the 1734-IE4S alongside the complete nine-brand automation portfolio:\n  \u003ca href=\"\/collections\/allen-bradley\" style=\"color:#0056B3; text-decoration:underline;\"\u003eAllen-Bradley\u003c\/a\u003e,\n  \u003ca href=\"\/collections\/siemens\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSiemens\u003c\/a\u003e,\n  \u003ca href=\"\/collections\/mitsubishi\" style=\"color:#0056B3; text-decoration:underline;\"\u003eMitsubishi\u003c\/a\u003e,\n  \u003ca href=\"\/collections\/omron\" style=\"color:#0056B3; text-decoration:underline;\"\u003eOmron\u003c\/a\u003e,\n  \u003ca href=\"\/collections\/fanuc\" style=\"color:#0056B3; text-decoration:underline;\"\u003eFanuc\u003c\/a\u003e,\n  \u003ca href=\"\/collections\/schneider\" style=\"color:#0056B3; text-decoration:underline;\"\u003eSchneider\u003c\/a\u003e,\n  \u003ca href=\"\/collections\/yaskawa\" style=\"color:#0056B3; text-decoration:underline;\"\u003eYaskawa\u003c\/a\u003e,\n  \u003ca href=\"\/collections\/panasonic\" style=\"color:#0056B3; text-decoration:underline;\"\u003ePanasonic\u003c\/a\u003e,\n  \u003ca href=\"\/collections\/keyence\" style=\"color:#0056B3; text-decoration:underline;\"\u003eKEYENCE\u003c\/a\u003e.\n  For complete safety system BOMs — including safety PLCs, I\/O, contactors, and\n  relays — contact \u003cstrong\u003eMoritta@KOEED.COM\u003c\/strong\u003e for consolidated sourcing.\n\u003c\/p\u003e\n\n\u003c!-- ============ Inquiry CTA ============ --\u003e\n\u003ch2 style=\"font-family:Arial, Helvetica, sans-serif; color:#111111; font-size:22px; line-height:30px; margin:32px 0 16px 0;\"\u003e\n  Request a Quote — 1734-IE4S\n\u003c\/h2\u003e\n\n\u003cdiv style=\"background-color:#16c8c8; padding:24px 32px; margin:16px 0; text-align:center;\n            font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003ch3 style=\"margin:0 0 12px 0; color:#ffffff; font-size:20px; line-height:28px;\"\u003e\n    Need this safety module or a complete safety system BOM?\n  \u003c\/h3\u003e\n  \u003cp style=\"margin:0 0 16px 0; color:#ffffff; font-size:15px; line-height:22px;\"\u003e\n    Send your part numbers to \u003cstrong\u003eMoritta@KOEED.COM\u003c\/strong\u003e and receive availability + pricing within 24 hours.\n  \u003c\/p\u003e\n  \u003ca href=\"mailto:Moritta@KOEED.COM?subject=RFQ%20%E2%80%94%20AB%201734-IE4S\" style=\"display:inline-block; background-color:#ffffff; color:#0056B3; padding:12px 24px;\n            text-decoration:none; font-weight:bold; border-radius:4px; font-size:15px;\"\u003e\n    Request a Quote →\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"border:1px solid #0056B3; padding:16px 24px; margin:16px 0; text-align:left;\n            font-family:Arial, Helvetica, sans-serif; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 8px 0; color:#111111; font-size:15px; line-height:22px;\"\u003e\n    Also need safety PLCs, guard relays, or POINT I\/O adapters?\n  \u003c\/p\u003e\n  \u003ca href=\"\/collections\/allen-bradley\" style=\"display:inline-block; color:#0056B3; padding:6px 18px;\n            text-decoration:none; font-weight:bold; border:1px solid #0056B3;\n            border-radius:4px; font-size:14px;\"\u003e\n    Browse Allen-Bradley Safety →\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\/\",\"@type\":\"Product\",\"name\":\"Allen-Bradley 1734-IE4S POINT I\/O Safety Analog Input Module\",\"brand\":{\"@type\":\"Brand\",\"name\":\"Allen-Bradley\"},\"category\":\"Safety I\/O Module\",\"sku\":\"1734-IE4S\",\"mpn\":\"1734-IE4S\",\"description\":\"AB 1734 POINT I\/O safety analog input, 4CH single-ended, SIL 2\/PL d. For safety instrumented systems and machine guarding.\",\"url\":\"\/products\/new-allen-bradley-1734-ie4s-1734ie4s-safety-input-module\",\"offers\":{\"@type\":\"Offer\",\"availability\":\"https:\/\/schema.org\/InStock\",\"url\":\"\/products\/new-allen-bradley-1734-ie4s-1734ie4s-safety-input-module\",\"seller\":{\"@type\":\"Organization\",\"name\":\"KOEED\"}}}\n\u003c\/script\u003e","brand":"ALLEN-BRADLEY","offers":[{"title":"Default Title","offer_id":44157535060153,"sku":"355551080128","price":918.52,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0268\/8476\/7929\/files\/s-l1600_cad39805-5bb2-4640-83c8-bbfb99ef638c.jpg?v=1715690788","url":"https:\/\/koeed.com\/products\/new-allen-bradley-1734-ie4s-1734ie4s-safety-input-module","provider":"KOEED","version":"1.0","type":"link"}