{"product_id":"1pc-new-open-box-jva-118-226-1-f-fast","title":"1PC JVA-118-226-1\/F Fast New-Open Box Product","description":"\u003cdiv class=\"koeed-container\" style=\"width:100%;color:#222;line-height:1.7;\"\u003e\n\n  \u003cstyle\u003e\n    .koeed-container h2,\n    .koeed-container h3{\n      color:#16c8c8;\n      margin-top:32px;\n      margin-bottom:14px;\n    }\n\n    .koeed-container table{\n      width:100%;\n      border-collapse:collapse;\n    }\n\n    .koeed-container th,\n    .koeed-container td{\n      border:1px solid #eeeeee;\n      padding:10px;\n      text-align:left;\n      vertical-align:top;\n    }\n\n    .koeed-container th{\n      background:#16c8c8;\n      color:#fff;\n    }\n\n    .koeed-container tr:nth-child(odd){\n      background:#f4fcfc;\n    }\n\n    .koeed-container tr:nth-child(even){\n      background:#fafafa;\n    }\n\n    .koeed-highlight{\n      color:#16c8c8;\n      font-weight:bold;\n    }\n\n    .koeed-note{\n      background:#f4fcfc;\n      border-left:4px solid #16c8c8;\n      padding:14px;\n      margin-top:18px;\n    }\n\n    .koeed-list li{\n      margin-bottom:8px;\n    }\n  \u003c\/style\u003e\n\n  \u003ch2\u003eEngineer's Quick Brief\u003c\/h2\u003e\n\n  \u003cul class=\"koeed-list\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eASCO JVA-118-226-1\/F\u003c\/strong\u003e is an industrial \u003cstrong\u003esolenoid valve coil assembly\u003c\/strong\u003e commonly associated with \u003cstrong\u003eASCO Joucomatic NBB307 series pneumatic valves\u003c\/strong\u003e.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003e0–10 bar operating pressure\u003c\/strong\u003e capability supports industrial air, gas, water, and light oil control systems in automation and marine environments.\u003c\/li\u003e\n\n    \u003cli\u003eDesigned for \u003cstrong\u003e24V DC operation\u003c\/strong\u003e with approximately \u003cstrong\u003e10W coil power consumption\u003c\/strong\u003e, suitable for hazardous-area and industrial switching applications.\u003c\/li\u003e\n\n    \u003cli\u003eFrequently used in \u003cstrong\u003emarine automation systems\u003c\/strong\u003e, pneumatic control manifolds, process skids, and industrial actuator assemblies.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2\u003eSEO Introduction\u003c\/h2\u003e\n\n  \u003cp\u003e\n    The \u003cstrong\u003eASCO JVA-118-226-1\/F\u003c\/strong\u003e is a heavy-duty industrial \n    \u003cstrong\u003esolenoid valve coil and actuator assembly\u003c\/strong\u003e used in \n    \u003cstrong\u003eASCO Joucomatic pneumatic valve systems\u003c\/strong\u003e. This model is commonly found in \n    industrial automation, marine control systems, compressed air regulation networks, \n    hazardous-area process equipment, and fluid control applications requiring reliable \n    \u003cstrong\u003e24V DC solenoid actuation\u003c\/strong\u003e.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    Associated with \u003cstrong\u003eNBB307 series valve bodies\u003c\/strong\u003e, the JVA-118-226-1\/F assembly supports \n    media including air, gas, water, and light oil under pressure ranges up to \n    \u003cstrong\u003e10 bar\u003c\/strong\u003e. The device is also referenced with \n    \u003cstrong\u003eBaseefa explosion-protection certification\u003c\/strong\u003e and EN industrial compliance markings in \n    secondary industrial spare-part channels.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    Common industrial search entities include:\n    \u003cstrong\u003eASCO Joucomatic valve\u003c\/strong\u003e,\n    \u003cstrong\u003eJVA-118-226-1\/F coil\u003c\/strong\u003e,\n    \u003cstrong\u003e24V DC solenoid valve\u003c\/strong\u003e,\n    \u003cstrong\u003e0-10 bar pneumatic valve\u003c\/strong\u003e,\n    \u003cstrong\u003emarine automation valve\u003c\/strong\u003e,\n    and \u003cstrong\u003ehazardous area solenoid actuator\u003c\/strong\u003e.\n  \u003c\/p\u003e\n\n  \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n  \u003cdiv style=\"overflow-x:auto;\"\u003e\n    \u003ctable\u003e\n      \u003ctr\u003e\n        \u003cth\u003eParameter\u003c\/th\u003e\n        \u003cth\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eManufacturer\u003c\/td\u003e\n        \u003ctd\u003eASCO \/ Joucomatic\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eModel\u003c\/td\u003e\n        \u003ctd\u003eJVA-118-226-1\/F\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eProduct Type\u003c\/td\u003e\n        \u003ctd\u003eIndustrial Solenoid Valve Coil \/ Solenoid Valve Assembly\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eAssociated Valve Series\u003c\/td\u003e\n        \u003ctd\u003eNBB307C9 \/ NBB307 Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eOperating Voltage\u003c\/td\u003e\n        \u003ctd\u003e24V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd\u003e10W\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eOperating Pressure\u003c\/td\u003e\n        \u003ctd\u003e0 – 10 bar\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eSupported Media\u003c\/td\u003e\n        \u003ctd\u003eAir, Gas, Water, Light Oil\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eOrifice Size\u003c\/td\u003e\n        \u003ctd\u003e9 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003ePipe Connection\u003c\/td\u003e\n        \u003ctd\u003eN1\/4\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eFluid Temperature\u003c\/td\u003e\n        \u003ctd\u003eUp to 50°C\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n        \u003ctd\u003eUp to 50°C\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eCable Entry Temperature\u003c\/td\u003e\n        \u003ctd\u003e68°C\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eExplosion Protection Reference\u003c\/td\u003e\n        \u003ctd\u003eBaseefa Ex 87B1110\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eCompliance Reference\u003c\/td\u003e\n        \u003ctd\u003eCENELEC EN50018 \/ BS5501 Pt5 EExd IICT5\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eApproximate Weight\u003c\/td\u003e\n        \u003ctd\u003e5.250 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eIndustrial Application Category\u003c\/td\u003e\n        \u003ctd\u003ePneumatic Automation \/ Marine Fluid Control \/ Process Control\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eTypical Installation Environment\u003c\/td\u003e\n        \u003ctd\u003eIndustrial automation cabinets, valve islands, marine systems\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eCondition in Secondary Market\u003c\/td\u003e\n        \u003ctd\u003eNew Open Box \/ Refurbished \/ Surplus Industrial Stock\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"koeed-note\"\u003e\n    \u003cstrong\u003eEngineering Note:\u003c\/strong\u003e\u003cbr\u003e\n    JVA-118-226-1\/F is frequently supplied through industrial surplus and automation spare-part channels.\n    Verification of coil voltage, hazardous-area certification, and valve body compatibility is recommended before installation.\n  \u003c\/div\u003e\n\n  \u003ch2\u003eApplication Matrix\u003c\/h2\u003e\n\n  \u003cdiv style=\"overflow-x:auto;\"\u003e\n    \u003ctable\u003e\n      \u003ctr\u003e\n        \u003cth\u003eIndustry\u003c\/th\u003e\n        \u003cth\u003eApplication\u003c\/th\u003e\n        \u003cth\u003eOperational Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eMarine Automation\u003c\/td\u003e\n        \u003ctd\u003ePneumatic control circuits and engine-room valve actuation\u003c\/td\u003e\n        \u003ctd\u003eSupports reliable switching in harsh industrial environments\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eIndustrial Automation\u003c\/td\u003e\n        \u003ctd\u003eCompressed air manifolds and process valve control\u003c\/td\u003e\n        \u003ctd\u003eStable 24V DC operation for PLC-controlled systems\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eProcess Industry\u003c\/td\u003e\n        \u003ctd\u003eFluid routing and media isolation systems\u003c\/td\u003e\n        \u003ctd\u003eHandles air, gas, water, and light oil applications\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eHazardous Area Systems\u003c\/td\u003e\n        \u003ctd\u003eExplosion-protected actuator environments\u003c\/td\u003e\n        \u003ctd\u003eIndustrial certification references support regulated installations\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eOEM Equipment\u003c\/td\u003e\n        \u003ctd\u003eIntegrated pneumatic module assemblies\u003c\/td\u003e\n        \u003ctd\u003eCompatible with ASCO Joucomatic valve ecosystems\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eTroubleshooting \u0026amp; FAQ\u003c\/h2\u003e\n\n  \u003ch3\u003eWhy is the solenoid valve not actuating?\u003c\/h3\u003e\n  \u003cp\u003e\n    Verify that the supply voltage matches the required \u003cstrong\u003e24V DC\u003c\/strong\u003e rating. \n    Coil undervoltage, connector corrosion, or damaged wiring can prevent proper magnetic actuation.\n  \u003c\/p\u003e\n\n  \u003ch3\u003eCan JVA-118-226-1\/F be used with water or oil?\u003c\/h3\u003e\n  \u003cp\u003e\n    Available industrial references indicate compatibility with \n    \u003cstrong\u003eair, gas, water, and light oil\u003c\/strong\u003e. \n    Fluid cleanliness and viscosity should still be evaluated against the installed valve body specifications.\n  \u003c\/p\u003e\n\n  \u003ch3\u003eWhat pressure range is supported?\u003c\/h3\u003e\n  \u003cp\u003e\n    Secondary industrial documentation references an operating range of \n    \u003cstrong\u003e0–10 bar\u003c\/strong\u003e for compatible valve assemblies.\n  \u003c\/p\u003e\n\n  \u003ch3\u003eHow should the coil temperature be evaluated during operation?\u003c\/h3\u003e\n  \u003cp\u003e\n    Elevated coil temperatures can occur during continuous-duty energization. \n    Ensure proper ventilation and confirm that ambient temperature remains within specified industrial limits.\n  \u003c\/p\u003e\n\n  \u003ch3\u003eIs this model suitable for hazardous-area installation?\u003c\/h3\u003e\n  \u003cp\u003e\n    Some industrial references list explosion-protection compliance markings including \n    \u003cstrong\u003eBaseefa Ex 87B1110\u003c\/strong\u003e and \n    \u003cstrong\u003eEExd IICT5\u003c\/strong\u003e. \n    Final hazardous-area approval depends on the complete installed assembly and local regulations.\n  \u003c\/p\u003e\n\n  \u003ch2\u003eCross-Reference \u0026amp; Selection\u003c\/h2\u003e\n\n  \u003ch3\u003eCross-Reference Guide\u003c\/h3\u003e\n\n  \u003cdiv style=\"overflow-x:auto;\"\u003e\n    \u003ctable\u003e\n      \u003ctr\u003e\n        \u003cth\u003eReference Type\u003c\/th\u003e\n        \u003cth\u003eRelated Model\u003c\/th\u003e\n        \u003cth\u003eNotes\u003c\/th\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eAssociated Valve Body\u003c\/td\u003e\n        \u003ctd\u003eNBB307C9\u003c\/td\u003e\n        \u003ctd\u003eFrequently referenced with JVA-118-226-1\/F coil assemblies\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eSeries Reference\u003c\/td\u003e\n        \u003ctd\u003eNBB307 Series\u003c\/td\u003e\n        \u003ctd\u003eASCO Joucomatic pneumatic valve family\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eIndustrial Category\u003c\/td\u003e\n        \u003ctd\u003e24V DC Solenoid Valve Assemblies\u003c\/td\u003e\n        \u003ctd\u003eUsed in PLC-driven pneumatic automation systems\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eHazardous Area Reference\u003c\/td\u003e\n        \u003ctd\u003eEExd IICT5 Valve Systems\u003c\/td\u003e\n        \u003ctd\u003eApplicable to explosion-protected industrial installations\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eAlternative Marking Variant\u003c\/td\u003e\n        \u003ctd\u003eJVA-118-226-1\/FF\u003c\/td\u003e\n        \u003ctd\u003eObserved in industrial distribution references\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003cscript type=\"application\/ld+json\"\u003e\n  {\n    \"@context\":\"https:\/\/schema.org\",\n    \"@type\":\"FAQPage\",\n    \"mainEntity\":[\n      {\n        \"@type\":\"Question\",\n        \"name\":\"Why is the solenoid valve not actuating?\",\n        \"acceptedAnswer\":{\n          \"@type\":\"Answer\",\n          \"text\":\"Verify that the supply voltage matches the required 24V DC rating. Coil undervoltage, connector corrosion, or damaged wiring can prevent proper magnetic actuation.\"\n        }\n      },\n      {\n        \"@type\":\"Question\",\n        \"name\":\"Can JVA-118-226-1\/F be used with water or oil?\",\n        \"acceptedAnswer\":{\n          \"@type\":\"Answer\",\n          \"text\":\"Available industrial references indicate compatibility with air, gas, water, and light oil. Fluid cleanliness and viscosity should still be evaluated against the installed valve body specifications.\"\n        }\n      },\n      {\n        \"@type\":\"Question\",\n        \"name\":\"What pressure range is supported?\",\n        \"acceptedAnswer\":{\n          \"@type\":\"Answer\",\n          \"text\":\"Industrial references indicate an operating pressure range of 0-10 bar for compatible valve assemblies.\"\n        }\n      },\n      {\n        \"@type\":\"Question\",\n        \"name\":\"Is this model suitable for hazardous-area installation?\",\n        \"acceptedAnswer\":{\n          \"@type\":\"Answer\",\n          \"text\":\"Industrial references list explosion-protection compliance markings including Baseefa Ex 87B1110 and EExd IICT5. Final approval depends on the installed assembly and local regulations.\"\n        }\n      }\n    ]\n  }\n  \u003c\/script\u003e\n\n\u003c\/div\u003e","brand":"JAVADEVICE","offers":[{"title":"Default Title","offer_id":44202665935033,"sku":"126362793538","price":4121.63,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0268\/8476\/7929\/files\/1PC_JVA_118_226_1_F_Fast_New_Open_Box_Product___JAVADEVICE__1.webp?v=1779638561","url":"https:\/\/koeed.com\/sr\/products\/1pc-new-open-box-jva-118-226-1-f-fast","provider":"KOEED","version":"1.0","type":"link"}