Carel BL0T3B00H0 Steam Cylinder: Complete Guide to Industrial Humidification Control

Carel BL0T3B00H0 Steam Cylinder: Complete Guide to Industrial Humidification Control

Carel BL0T3B00H0 Steam Cylinder: Industrial Humidification Excellence

The Carel BL0T3B00H0 represents the pinnacle of industrial humidification technology, designed specifically for integration with PLC-controlled automation systems. This steam cylinder is engineered for precision humidity control in demanding industrial environments.

Product Overview

The BL0T3B00H0 is a three-phase steam cylinder designed for Carel's HumiSteam isothermal immersed electrode humidifiers. This industrial-grade component plays a crucial role in maintaining optimal humidity levels in various industrial applications, from manufacturing facilities to data centers and clean rooms.

Carel BL0T3B00H0 Steam Cylinder Front View
Carel BL0T3B00H0 Technical Specifications
Carel BL0T3B00H0 Installation View
Carel BL0T3B00H0 Component Details
Carel BL0T3B00H0 Electrical Connections
Carel BL0T3B00H0 Manufacturing Details
Carel BL0T3B00H0 Quality Control
Carel BL0T3B00H0 Packaging
Carel BL0T3B00H0 Technical Diagram
Carel BL0T3B00H0 Safety Features
Carel BL0T3B00H0 Performance Data
Carel BL0T3B00H0 Industrial Application
Carel BL0T3B00H0 Maintenance Guide

Product Demonstration Video

Technical Specifications

Parameter Specification Details
Product Type Steam Cylinder For HumiSteam isothermal immersed electrode humidifier
Manufacturer Carel Leading industrial humidification solutions provider
Capacity 10-15 kg/h Three-phase operation
Cylinder Type Type B Standard disposable cylinder
Cylinder Rating B - conductivity from 75 Optimized for specific water conductivity levels
Humidification 30 mm (1.18 in) Precision steam generation
Warranty Period 3 to 12 Months Varies by supplier and application
Dimensions 16.4 inches (41.656 cm) Height specification
Diameter 9.9 inches (25.146 cm) Standard industrial size
Weight 4.46 kg Approximate shipping weight
Phase Configuration Three-phase Industrial power requirements
PLC Compatibility Full Integration Designed for automated control systems

Key Features and Benefits

Industrial-Grade Performance

The BL0T3B00H0 steam cylinder delivers reliable 10-15 kg/h humidification capacity, making it ideal for medium to large industrial applications. Its three-phase design ensures stable operation in demanding environments.

PLC Integration Capabilities

This steam cylinder is specifically designed for seamless integration with PLC-controlled automation systems. It features standardized interfaces and control protocols that allow for:

  • Precise humidity level monitoring and control
  • Automated maintenance scheduling
  • Real-time performance monitoring
  • Integration with building management systems (BMS)
  • Remote monitoring and control capabilities

Advanced Safety Features

The Carel BL0T3B00H0 incorporates multiple safety mechanisms including:

  • Over-temperature protection
  • Low water level detection
  • Electrical safety interlocks
  • Automatic shut-off systems
  • Ground fault protection

Industrial Applications

Manufacturing Facilities

Maintain optimal humidity levels for production processes, preventing static electricity and ensuring product quality in electronics, pharmaceutical, and precision manufacturing.

Data Centers

Protect sensitive electronic equipment from electrostatic discharge and maintain optimal operating conditions for servers and networking equipment.

Clean Rooms

Provide precise humidity control for pharmaceutical, semiconductor, and biotechnology facilities where environmental conditions are critical.

Commercial Buildings

Enhance indoor air quality and comfort in office buildings, hospitals, museums, and archives where humidity control is essential.

Installation and Maintenance

The BL0T3B00H0 steam cylinder is designed for straightforward installation and maintenance:

  1. Pre-installation Check: Verify power supply compatibility and water quality
  2. Mounting: Secure in designated humidifier housing
  3. Electrical Connection: Connect three-phase power supply following local electrical codes
  4. Water Connection: Connect to appropriate water supply with proper filtration
  5. PLC Integration: Connect control signals to automation system
  6. Testing: Perform functional tests and calibration

Frequently Asked Questions (FAQ)

What is the typical lifespan of the BL0T3B00H0 steam cylinder?

The steam cylinder typically lasts 3-12 months depending on water quality, usage frequency, and maintenance practices. Regular monitoring and proper water treatment can extend its lifespan.

Can this steam cylinder be integrated with existing PLC systems?

Yes, the BL0T3B00H0 is designed for seamless integration with most industrial PLC systems. It features standard control interfaces and can be programmed for automated operation.

What water quality is required for optimal performance?

The Type B cylinder is rated for water conductivity from 75 μS/cm. For best results, use properly treated water with appropriate conductivity levels and minimal mineral content.

How does the three-phase design benefit industrial applications?

Three-phase operation provides more stable power distribution, higher efficiency, and better performance consistency compared to single-phase systems, making it ideal for continuous industrial operation.

What maintenance is required for this steam cylinder?

Regular maintenance includes monitoring water quality, checking electrical connections, and replacing the cylinder as needed based on performance indicators and PLC monitoring data.

Trust and Quality Assurance

Manufacturer Reputation: Carel is a globally recognized leader in industrial humidification solutions with over 40 years of experience.

Certifications: Products comply with international standards including CE, UL, and RoHS directives.

Industry Adoption: Widely used in critical applications across multiple industries including pharmaceuticals, data centers, and manufacturing.

Technical Support: Comprehensive technical documentation and manufacturer support available.

Warranty Coverage: Standard warranty periods from 3 to 12 months depending on supplier and application.

Technical References and Resources

For additional technical information and support:

  • Manufacturer Documentation: Complete technical manuals available from Carel
  • PLC Integration Guides: Specific protocols for major automation platforms
  • Installation Videos: Step-by-step installation guidance
  • Maintenance Schedules: Recommended service intervals and procedures
  • Troubleshooting Guides: Common issues and solutions

Important Considerations

When implementing the BL0T3B00H0 in your automation system:

  1. Ensure proper water treatment to extend cylinder life
  2. Verify electrical compatibility with local power standards
  3. Implement proper PLC programming for automated control
  4. Establish regular maintenance schedules
  5. Monitor performance through your automation system

Conclusion

The Carel BL0T3B00H0 steam cylinder represents a sophisticated solution for industrial humidification needs, offering reliable performance, seamless PLC integration, and robust construction for demanding applications. Its 10-15 kg/h capacity and three-phase design make it suitable for a wide range of industrial environments where precise humidity control is essential for process quality, equipment protection, and operational efficiency.