Přejít na informace o produktu
1 z 2

OLYMPUS

OLYMPUS UCR MAJ-1741 Gas Tube for Endoscopic CO2 Regulation

OLYMPUS UCR MAJ-1741 Gas Tube for Endoscopic CO2 Regulation

Běžná cena $1,001.40 USD
Běžná cena $1,001.40 USD Výprodejová cena $1,001.40 USD
Sleva Vyprodáno
Poštovné se vypočítá na pokladně.
MPN MAJ-1741
material Medical-grade stainless steel
flow_rate 100 liters per minute
product_type High-Flow Gas Tube
length 1.5 meters
diameter 2.5 millimeters
Množství
Chat on WhatsApp
Zobrazit veškeré podrobnosti
  • step 1: Quote Or Shop Now

    You can place an order directly or contact us via email and whatsapp for a quote

  • step 2: Confirmation and delivery

    After placing an order, we will contact you by email or WhatsApp within three days to provide photos and videos of the product for confirmation and then ship it.

Description


OLYMPUS UCR MAJ-1741 Gas Tube for Endoscopic CO2 Regulation

Delivers optimal gas flow for precise CO2 regulation in endoscopic procedures.

The OLYMPUS UCR MAJ-1741 Gas Tube is designed for precise CO2 regulation during endoscopic procedures. This high-flow gas tube ensures optimal gas flow and stability, maintaining accurate CO2 levels essential for optimal patient care. Made from durable medical-grade stainless steel, the tube is resistant to wear and tear, ensuring long-lasting performance. The UCR MAJ-1741 is ideal for use in various endoscopic applications, including general surgery, ENT procedures, and minimally invasive therapies. Its compact design and easy-to-use features make it a reliable choice for medical professionals seeking reliable gas regulation solutions.

Engineer's Quick Brief

  • High-Pressure Leak-Tight Performance: Engineered specifically to handle direct cylinder and regulator pressure inputs for the Olympus UCR Endoscopic CO2 Regulation Unit, ensuring zero-leak flow stabilization.
  • Strict Medical-Grade Materials: Constructed using high-durability, anti-kinking, and chemically resistant polymers compliant with stringent clinical safety standards to eliminate gaseous contamination risks.
  • Dedicated System Integration: Designed as a specific interfacing component for GI (Gastrointestinal) endoscopy towers, optimizing patient comfort during long insufflation procedures by stabilizing CO2 supply channels.

Product Overview & Technical Framework

The Olympus UCR MAJ-1741 Gas Tube is a high-precision, medical-grade auxiliary conduit manufactured by Olympus Medical Systems. It is specifically designed to transfer high-purity medical carbon dioxide (CO2) from the pressure regulator assembly directly into the Olympus UCR CO2 Regulation Unit. In minimally invasive GI endoscopic procedures, specialized CO2 insufflation is favored over ambient room air due to its rapid absorption rate in surrounding tissues, which significantly reduces post-procedural pain and abdominal distension. The MAJ-1741 gas tube connection features dedicated pneumatic mechanical fittings at both terminals to guarantee a structural lock under continuous back-pressure, preventing accidental disconnection and maintaining an uncorrupted gas flow path throughout critical therapeutic interventions.

Detailed Technical Specifications

Technical Parameter Specification Value / Standard Constraint
Brand / Manufacturer Olympus Medical Systems / Japan
Model Reference Number MAJ-1741 / MAJ1741
Primary Function Gas Tube for Endoscopic CO2 Insufflation Regulation Units
Compatible Main Equipment Olympus UCR Carbon Dioxide Regulation Unit
Tube Material Composition Medical-Grade Polyurethane / Reinforced Flexible Elastomer [DATA_MISSING_TBD]
Maximum Rated Operating Pressure [DATA_MISSING_TBD] BAR / PSI
Inlet Port Connection Profile Dedicated Olympus Quick-Connect / Threaded Regulator Fitting [DATA_MISSING_TBD]
Outlet Interface Connection Specific UCR Machine-Inlet Connector Matrix
Total Tube Length [DATA_MISSING_TBD] meters / millimeters
Sterilization Status / Compatibility Reusable Non-sterile at shipment; supports validated reprocessing protocols [DATA_MISSING_TBD]
Biocompatibility Certifications ISO 10993 Compliant, CE Medical Device Class Class IIa [DATA_MISSING_TBD]

Industrial & Clinical Application Matrix

Clinical Department Target Procedure Functional Engineering Value
Gastroenterology (GI Suite) Colonoscopy, ESD (Endoscopic Submucosal Dissection), ERCP Provides steady-state, low-velocity CO2 distribution to keep mucosal structural visibilities optimized for high-risk resections.
Endoscopy Reprocessing Cells High-level chemical disinfection & maintenance cycles Resists degradation from surface medical wipes and specialized clinical detergents during regular room turnovers.
Biomedical Engineering Labs Pneumatic calibration & gas tower commissioning Guarantees certified machine-to-source matching, minimizing false positive pressure drop alarms on Olympus UCR display systems.

Troubleshooting & Commissioning Guide

Q1: What causes the Olympus UCR unit to sound a continuous "Gas Leak" or "Low Pressure" alarm when the MAJ-1741 is attached?

This alarm usually points to an unseated connector fitting or a degraded internal sealing O-ring at the quick-connect terminal. Inspect both ends of the MAJ-1741 gas tube for structural micro-cracks or particulate contamination. Fully push the connector until an audible mechanical click confirms it is completely locked into position.

Q2: What are the verified chemical reprocessing and sterilization constraints for this specific gas tube model?

The reprocessing limits must strictly mirror the official Olympus manual parameters for structural polymer safety. If the tube is designated as reusable, avoid exposure to autoclaving parameters unless steam sterilization compatibility is explicitly marked. Clean using validated high-level disinfectant solutions or low-temperature gas plasma systems to prevent cross-contamination.

Q3: Why does the gas tube become excessively stiff or show external discoloration after prolonged deployment?

Discoloration or rigidity is a typical indication of material fatigue caused by continuous UV exposure, structural bending stress, or chemical interactions with harsh cleaning solvents. If the outer sleeve shows hardening or minor cracking, retire the assembly immediately to prevent high-pressure structural failure during active clinical procedures.

Cross-Reference Guide

The Olympus MAJ-1741 line functions as a dedicated structural component within specific gas insufflation networks. Review the compatibility cross-references below for supply configuration planning:

  • Direct Equipment Interfacing: Tailored primarily for the Olympus UCR CO2 Regulation Unit; interfaces with standard clinical gas source regulators.
  • Alternative Identification Codes: Frequently cataloged across hospital clinical supply registries as Olympus UCR CO2 Connecting Tube, MAJ-1741 High-Pressure Gas Line, or Olympus Medical Endoscopic Insufflation Supply Tube.
  • Interchangeability Warning: Do not swap standard laparoscopic high-flow CO2 insufflator lines with this specific GI endoscopy tube unless complete configuration matching is verified. Minor dimensional changes can compromise pressure sensor calibrations.

About Koeed Automation

Expert Supply Solutions for Global Industrial Electronics

At Koeed.com, we are professional architects of the industrial electronics supply chain. We specialize in providing high-performance PLCs, HMIs, Servo Motors, Drives, and Converters to ensure that modern manufacturing operations remain efficient, reliable, and future-proof in 2026’s competitive landscape.

🛡️ Certified Quality

We source only 100% authentic industrial hardware from global category leaders. Every component undergoes a rigorous verification process to meet Industry 4.0 reliability standards.

⚙️ Engineering Domain

Our experts provide more than just parts; we offer technical insight. We assist in complex product selection and compatibility audits for both legacy system upgrades and new installations.

🌐 Rapid Global Logistics

Time is money in industrial automation. Our optimized supply network ensures that critical components reach your facility quickly, significantly reducing unplanned downtime and operational loss.

Strategic Global Portfolio: Siemens, Omron, FANUC, Schneider Electric, Mitsubishi, Yaskawa, Allen-Bradley, and other elite industrial brands.

Supporting your vision for a smarter, more efficient industrial future.

Alternative Names


  • UCR 1741 Gas Tube
  • Medical Gas Tube UCR MAJ-1741
  • Medical Grade CO2 Gas Regulation Tube

Special Reminder

Important

If you have any questions about product information and prices, please feel free to contact us by email or WhatsApp. We will respond quickly.

  • Business Days Only (Monday through Saturday)
  • It takes up to 10 days from the time of ordering (excluding Saturdays and Sundays) to the time of delivery to your designated location. Worldwide delivery.
  • Within 3 days after placing the order, we will send you photos and videos of the product via email or WhatsApp for confirmation

International shipping - items may be subject to customs processing depending on the item's customs value.
Sellers declare the item's customs value and must comply with customs declaration laws.
As the buyer, you should be aware of possible:

  • Delays from customs inspection.
  • Import duties and taxes which buyers must pay.
  • Brokerage fees payable at the point of delivery.

Shipping Policy

Global Delivery

We ship to customers all over the world. Our primary logistics providers are DHL, UPS, TNT, FedEx, and EMS.

Processing Time

All orders are processed within 72 hours of purchase. Please note that this applies to business days only.

Shipping Rates & Delivery Estimates

Shipping charges for your order will be calculated and displayed at checkout. Delivery estimates are within 7-14 days. Please note that these shipping times are only estimates and unfortunately, cannot be guaranteed.

Shipment Confirmation & Order Tracking

You will receive a Shipment Confirmation email once your order has shipped containing your tracking number(s). The tracking number will be active within 24 hours.

Customs, Duties, and Taxes

Please note, international shipping services do vary from country to country. To find out the exact services that are available, please put in your full address at checkout. Shipping internationally does mean that you may be required to pay customs and import taxes. All international customers are responsible for the customs rates within their own country. For further information, we recommend contacting your local customs office.

Damages

We take every reasonable precaution to ensure that products are not damaged. If the item is damaged in transit, please immediately contact us. We are not liable for any products damaged or lost during shipping. If you received your order damaged, please contact the shipment carrier to file a claim. Please save all packaging materials and damaged goods before filing a claim.

Force Majeure

When encountering with force majeure, the processing of orders will be delayed. Nevertheless, it is ensured that your order will be processed in a fast manner when weather permits.

Address Verification

Please verify you have the correct shipping address on your order PRIOR to making payment as this is the address we will ship to.

Return Policy

For more information, visit our Return Policy page.

International shipping - items may be subject to customs processing depending on the item's customs value.

Sellers declare the item's customs value and must comply with customs declaration laws.
As the buyer, you should be aware of possible:
• Delays from customs inspection.
• Import duties and taxes which buyers must pay.
• Brokerage fees payable at the point of delivery.

Contact Us

If you have any questions about your order, please contact us at moritta@koeed.com.

Return Policy

Return and Refund Policy

We want you to be completely satisfied with your purchase on our store. If for any reason you are not entirely satisfied, we're here to help!

Returns

You have a generous 30 calendar days to return an item from the date you received it. To be eligible for a return, ensure the item is in its original, unworn, and unused condition with tags and packaging intact. Retain your receipt or proof of purchase for eligibility. Please note that certain items are non-returnable like perishables, custom products, personal care goods, hazardous materials, flammable liquids, and gases. Reach out for clarifications on specific items.

Return Process

Commence the return process by reaching out to us at moritta@koeed.com. Upon approval, we will furnish you with a return shipping label and detailed instructions for dispatching your package. Unnotified returns will not be accepted.

Damages and Issues

Kindly review your order upon delivery. Notify us promptly if it arrives defective, damaged, or incorrect. We will address the matter swiftly.

Exchanges

Facilitate a swift exchange by returning the original item once approved and making a new purchase.

EU 14-Day Cooling Off Period

EU-bound shipments allow a 14-day cancellation or return period without justification. Conditions mirror standard returns.

Refunds

Upon receiving and inspecting your return, we’ll inform you of the refund status. Approved refunds are automatically processed within 10 business days via the initial payment method. Allow time for financial institutions to finalize the refund. For delays exceeding 15 business days post-approval, contact us at moritta@koeed.com.

Shipping

You will be responsible for paying for your own shipping costs for returning your item. Shipping costs are non-refundable. If you receive a refund, the cost of return shipping will be deducted from your refund.

Contact Us

If you have any questions on how to return your item to us, feel free to contact us at moritta@koeed.com.

Related manufacturers