Pro-face PFXPP170BA10N00N00 — PS5000 Series 15" Modular HMI / Panel PC
Pro-face (Schneider Electric) · PS5000 Series · 15" XGA Touch Panel · No OS
The PFXPP170BA10N00N00 is a modular 15-inch industrial operator panel from the
Pro-face / Schneider Electric
PS5000 family (now branded under Aveva Wonderware). It pairs a fanless XGA TFT display with analog resistive
touch, a black aluminum bezel, and front-side IP65 / IP66 / NEMA 4X protection — built for shop-floor
HMIs in factory automation
and process control. The unit ships without an operating system, giving system integrators
the freedom to load Windows, Linux, or a custom Pro-face runtime once the SSD / HDD and DC power module are
installed. KOEED sources PS5000 series spares for legacy line upgrades and active production cells alike.
Key Technical Specifications / Overview
| Brand |
Pro-face (Schneider Electric / Aveva Wonderware)
|
| Series |
PS5000 modular industrial panel PC
|
| Part Number |
PFXPP170BA10N00N00
|
| Module Type |
Modular industrial HMI / panel PC, 15" display module (no CPU box attached)
|
| Display |
15" XGA TFT, 1024 × 768, LED backlight
|
| Touch |
Analog resistive, single-touch
|
| Bezel |
Black anodized aluminum
|
| Front Protection |
IP65 / IP66 / NEMA 4X (indoor)
|
| Cooling |
Fanless passive cooling
|
| Operating System |
None pre-installed (customer / integrator loads Windows or Linux)
|
| Modular Options |
DC power supply, HDD / SSD storage, serial (RS-232 / RS-485), Ethernet expansion modules
|
| Typical Application |
SCADA / MES line HMI, recipe management, data collection on discrete and process lines
|
| Stock Status |
In stock — quote within 24 hours at Moritta@KOEED.COM
|
Engineering note: the "No OS" designation in the suffix is intentional — it lets one panel SKU serve
plants standardizing on Windows IoT, legacy Windows 7, or a stripped Linux build. Specifiers looking for a
drop-in replacement should review the modular options list before ordering.
Application Scenarios / Where It Fits
The PS5000 15" modular panel is a workhorse in factory automation
and discrete / process lines. The 15" XGA canvas, resistive touch, and NEMA 4X front make it ideal for
gloved operators on shop floors that still expect multi-vendor PLC connectivity. Typical placements include:
- Line-side HMI for SCADA / MES on packaging, bottling, and material handling cells
- Recipe and parameter management on food & beverage, pharmaceutical, and cosmetic batching skids
- Cell-level operator terminals for Allen-Bradley ControlLogix / CompactLogix cells
- Operator panels paired with Siemens SIMATIC S7-300 / S7-1500 PLCs via Modbus TCP or PROFINET gateways
- Machine-builder reference terminals for Mitsubishi MELSEC iQ-R and GOT-integration machines
- Vision-aided inspection cells alongside KEYENCE CV-5000 / XG-8000 cameras where the panel runs both HMI and inspection dashboards
- CNC and robotics cells with Fanuc 0i / 30i controllers and Yaskawa MP controllers
- Energy and water utilities using Schneider Modicon M340 / M580 in SCADA front-ends
- Compact OEM skids that pair with Omron CJ2 / CP1H and Panasonic FP7 controllers
Because the panel ships without an OS, integrators can standardize on a single image across
Allen-Bradley,
Siemens,
Mitsubishi,
Omron,
Fanuc,
Schneider,
Yaskawa,
Panasonic, and
KEYENCE
lines — reducing the SKU count a multi-plant maintenance team must keep on the shelf.
Integration & Wiring Notes
The PS5000 base display module exposes a single modular I/O bus to the rear expansion bay. Power, storage,
and field-bus interfaces are not built in — you add them as field-replaceable modules. Keep the following
wiring rules in mind for a clean install:
-
DC power module: feed a regulated 24 VDC source on a dedicated breaker; size conductors for
inrush at panel start-up and bond chassis ground at the panel stud, not at the cabinet door.
-
Ethernet: use shielded Cat 5e / Cat 6 to the LAN port; for Modbus TCP to
Allen-Bradley and
Schneider controllers,
segment the HMI VLAN from the plant floor to keep SCADA polling predictable.
-
RS-232 / RS-485 modules: required for older
Mitsubishi MELSEC-A,
Omron CP1, and
Panasonic FP7 PLCs
that lack a native Ethernet port — match baud rate, parity, and stop bits on both ends.
-
Storage: install an industrial-grade SSD (preferred) or HDD module before commissioning;
the panel will not boot to a runtime without a bootable image.
-
Touch calibration: resistive touch is sensitive to bezel torque — re-tighten the
mounting clamps evenly to avoid a skewed calibration after the panel is mounted in the cutout.
-
Chassis & grounding: use star-ground topology back to a single panel ground bar; the
aluminum bezel and rear heatsink must be bonded to the cabinet ground stud, never relied on as the only
return path.
Pre-integration checklist: confirm the OS image is licensed for the panel SKU, that any OPC UA / Modbus
security certificates are pre-staged, and that the PLC tag database is exported before the panel is
powered up the first time. The
PLC Hex to Float Converter
is handy for sanity-checking Modbus register scaling during the bench test.
Installation & Commissioning Tips
-
Cutout & bezel torque: the PS5000 15" display follows the standard Pro-face 396 × 277 mm
cutout. Insert the panel with all four corner clamps hand-tight, then torque evenly in a criss-cross pattern to
keep the resistive touch sensor flat against the bezel.
-
Panel cooling: the fanless design relies on the aluminum chassis for heat dissipation.
Maintain at least 50 mm clearance on top, bottom, and rear for convection, especially inside sealed cabinets.
-
First-boot image load: install the OS image on the SSD module before final mounting when
possible; the rear expansion bay is much easier to access on the bench than inside the cabinet.
-
Touch calibration sequence: run a five-point resistive touch calibration at the first
power-up, then again after the panel reaches operating temperature, then once more 24 hours after installation
to compensate for any bezel settling.
-
Field-bus commissioning: for Modbus TCP tie-ins to
Yaskawa MP controllers
or Fanuc CNC boards,
validate register maps with the
Modbus CRC Calculator
before live polling — a single swapped byte order can take down an entire HMI session.
-
Backup & restore: image the SSD once the project is signed off; keep a checksum
record on the maintenance server. Most PS5000 field failures are software or storage related, not display
hardware.
-
Spare module strategy: plants running
Siemens,
Allen-Bradley, and
KEYENCE lines from the
same cabinet typically stock one spare DC power module, one spare SSD module, and one spare Ethernet module
per cell — those three parts clear the majority of unplanned downtime events.
-
Obsolescence handling: when the PS5000 is EOL on a long-running line, the modular
architecture simplifies migration to a newer PS5000 or PS6000 display module while keeping the
back-of-panel wiring and field I/O intact. See the
AI Diagnostic Tool for
nameplate-based cross-reference help.
Procurement, Warranty & Lead Time
KOEED supplies the PFXPP170BA10N00N00 and the full PS5000 modular accessory set (DC power modules, SSD / HDD
modules, serial expansion, Ethernet expansion) as new surplus, factory-sealed, or tested-refurbished stock.
Pricing is quote-based — send your BOM, project name, and target delivery window to
Moritta@KOEED.COM
and the team will respond within 24 hours on business days. Worldwide shipping is via DHL or FedEx
with full tracking and export documentation; most orders ship from the Shenzhen / Hong Kong sourcing base
within 3–5 business days after payment clears.
All units pass a pre-shipment function test (display, touch, communication ports, expansion bay) and ship
with a 90-day warranty against functional defects. Extended 12-month coverage is available on
request for refurbished units. Lead times depend on configuration: display-only stock typically clears in
3–5 business days, while built-up panel PCs (panel + power + storage + OS image) require 7–10
business days for the staging and burn-in cycle.
Need this panel or a full BOM?
Send your part list to Moritta@KOEED.COM and get availability + price within 24 hours.
Request a Quote →
Questions before you order? Email
Moritta@KOEED.COM
with your project name, target delivery window, and the full panel / module BOM. Engineers at KOEED will
confirm availability, lead time, and the matching DC power, storage, and field-bus modules for a
drop-in install.