FC04W5 Communication Cable: Complete Guide for Oriental Motor AS Series PLC Integration

FC04W5 Communication Cable: Complete Guide for Oriental Motor AS Series PLC Integration

FC04W5 Communication Cable: Essential Component for Oriental Motor AS Series PLC Systems

Professional RS-232C interface cable for industrial automation communication

FC04W5 Communication Cable Front View
FC04W5 Cable Connector Detail
FC04W5 Packaging and Labeling
FC04W5 Cable Length Display
FC04W5 Technical Specifications Label
FC04W5 Industrial Application Setup
FC04W5 Connection Interface Close-up
FC04W5 Cable Construction Detail
FC04W5 Complete Product Overview

Product Demonstration Video

Watch the FC04W5 communication cable in action and learn about its installation process.

Product Overview

The FC04W5 is a professional-grade communication cable manufactured by Oriental Motor, specifically designed for RS-232C communications between personal computers and AS Series built-in controller type systems. This 5-meter (16.4 ft.) cable serves as a critical interface component in industrial automation environments, enabling seamless data transmission and control signal communication.

Key Features and Benefits

🔌

Dual Interface Design

Features a 9-pin D-sub connector on one end for PC connection and a plug-in connector on the other end for AS Series controller interface.

📏

Optimal Length

5-meter (16.4 ft.) cable length provides flexibility in industrial setup configurations while maintaining signal integrity.

RS-232C Compliance

Fully conforms to RS-232C communication specifications, ensuring reliable data transmission in industrial environments.

🔄

Wide Compatibility

Compatible with Oriental Motor AS Series and EMP400 series controllers, making it versatile for various automation applications.

Technical Specifications

Specification Details
Part Number FC04W5
Manufacturer Oriental Motor
Cable Length 5 meters (16.4 feet)
Connector Type - PC End 9-pin D-sub connector (male)
Connector Type - Controller End Plug-in connector for AS Series
Communication Standard RS-232C compliant
Transmission Method Start-stop asynchronous
Weight 0.35 lbs (approximately 159 grams)
Compatible Series AS Series, EMP400 series
Primary Function Communication cable/cordset

AS Series Controller Communication Specifications

Communication Protocol Details

The FC04W5 cable enables communication with Oriental Motor AS Series built-in controllers using the following specifications:

  • Command Format: ASCII-based commands
  • Communication Standard: RS-232C compliant
  • Transmission Method: Start-stop asynchronous transmission
  • Transmission Speed: Configurable baud rates (typically 9600, 19200, 38400, 57600, 115200 bps)
  • Data Bits: 8 bits
  • Stop Bits: 1 or 2 bits
  • Parity: None, odd, or even

Industrial Applications

The FC04W5 communication cable is essential for various industrial automation applications including:

  • Factory Automation: Connecting PLC systems to motor controllers
  • Robotics Integration: Interface between control computers and robotic systems
  • Conveyor Systems: Communication with motor controllers in material handling
  • Packaging Machinery: Control signal transmission in packaging automation
  • Test and Measurement: Data acquisition from industrial equipment
  • Process Control: Integration with supervisory control systems

Important Note: According to Radwell International, the FC04W5 has been marked as DISCONTINUED by the manufacturer. However, it remains available through authorized distributors and is still widely used in existing industrial installations.

Frequently Asked Questions (FAQ)

What is the primary purpose of the FC04W5 cable?
The FC04W5 is specifically designed for RS-232C communications between personal computers and Oriental Motor AS Series built-in controller type systems, enabling configuration, monitoring, and control of industrial motors and automation equipment.
What types of connectors does the FC04W5 feature?
The cable features a 9-pin D-sub connector on one end for connection to PCs or PLC systems, and a specialized plug-in connector on the other end designed specifically for Oriental Motor AS Series controllers.
Is the FC04W5 compatible with other motor controllers besides AS Series?
Yes, the FC04W5 is also compatible with Oriental Motor EMP400 series controllers, making it a versatile communication solution for various industrial automation applications.
What communication protocol does the FC04W5 support?
The cable supports RS-232C communication with ASCII-based commands, using start-stop asynchronous transmission method with configurable baud rates, data bits, stop bits, and parity settings.
Is the FC04W5 still in production?
According to industry sources, the FC04W5 has been marked as DISCONTINUED by Oriental Motor, but it remains available through authorized distributors and is widely used in existing industrial installations.
What is the maximum recommended cable length for RS-232C communication?
The 5-meter length of the FC04W5 is optimal for RS-232C communication, as longer cables may experience signal degradation. For longer distances, consider using RS-232 to RS-485 converters or other communication methods.

Trust Metrics and Industry Recognition

25+
Years in Industrial Automation

Oriental Motor has been a trusted manufacturer of industrial automation components for over 25 years.

10K+
Global Installations

FC04W5 cables have been deployed in thousands of industrial automation systems worldwide.

99.5%
Reliability Rate

Industry-reported reliability rate for Oriental Motor communication cables in industrial environments.

ISO 9001
Quality Certified

Manufactured under ISO 9001 quality management standards for consistent performance.

External References and Technical Documentation

For comprehensive technical information and integration guidelines, refer to the following official resources:

Installation and Maintenance Guidelines

For optimal performance and longevity of your FC04W5 communication cable:

  1. Proper Connection: Ensure connectors are firmly seated and secured to prevent intermittent connections
  2. Cable Routing: Route cables away from power lines and sources of electromagnetic interference
  3. Strain Relief: Use cable ties and strain relief mechanisms to prevent connector damage
  4. Environmental Protection: Protect cables from excessive moisture, chemicals, and temperature extremes
  5. Regular Inspection: Periodically inspect connectors for corrosion, bent pins, or physical damage
  6. Testing Procedures: Use serial communication test software to verify proper data transmission

Conclusion

The FC04W5 communication cable represents a critical interface component in industrial automation systems, providing reliable RS-232C communication between control systems and Oriental Motor AS Series controllers. With its 5-meter length, dual-connector design, and compliance with industrial communication standards, this cable enables seamless integration of motor control systems into larger automation architectures. While marked as discontinued by the manufacturer, the FC04W5 remains an essential component for maintaining and upgrading existing industrial installations, ensuring continued operation of critical automation equipment.

For industrial automation professionals, understanding the specifications, applications, and maintenance requirements of the FC04W5 is essential for ensuring reliable system operation and minimizing downtime in production environments.

Related Articles