HANDOUK

1Pc HANDOUK HL3-2A-12S 12VDC Power Relay 6Pins 5A 250VAC

1Pc HANDOUK HL3-2A-12S 12VDC Power Relay 6Pins 5A 250VAC

Regular price $21.42 USD
Regular price $21.42 USD Sale price $21.42 USD
Sale Sold out
Shipping calculated at checkout.
Condition used
MPN HL3-2A-12S
Quantity
View full details
  • step 1: Quote Or Shop Now

    You can place an order directly or contact us via email and whatsapp for a quote

  • step 2: Confirmation and delivery

    After placing an order, we will contact you by email or WhatsApp within three days to provide photos and videos of the product for confirmation and then ship it.

1Pc HANDOUK HL3-2A-12S 12VDC Power Relay — 6-Pin DPDT, 5A 250VAC

Handouk · HL3 Series · 12VDC Coil · 2 Form C (DPDT) · In stock

The Handouk HL3-2A-12S is a miniature 6-pin (DPDT / 2 Form C) power relay designed as a cost-effective drop-in for general-purpose industrial control panels. It carries a 12 V DC coil and a 5 A / 250 V AC contact rating in a transparent polycarbonate housing, with a pin footprint that mirrors common industry references such as the Omron G2R-2A and the Finder 55.34. KOEED stocks the Handouk HL3 family for engineers building or maintaining PLC I/O relay boards, and the unit is ready to ship worldwide from our China sourcing network.

1. Key Technical Specifications / Overview

The HL3-2A-12S belongs to Handouk’s HL3 series of miniature PCB- and socket-mount relays. The suffix breaks down as 2A = 2 Form C (DPDT) contacts and 12S = 12 V DC coil, a combination widely used on 24 V DC rail-derived control circuits and on 12 V DC battery systems. The full electrical and mechanical envelope is summarized in the ledger-style table below — these are the figures you will need to compare it against the relay you are currently designing in or replacing.

Brand Handouk (China OEM)
Series HL3 — miniature 6-pin power relay
Part Number HL3-2A-12S
Relay Type DPDT (2 Form C) — 6-pin, plug-in or PCB
Coil Voltage 12 V DC (12S suffix)
Coil Resistance Approx. 360–400 Ω
Coil Pickup Current Approx. 30–35 mA
Contact Rating 5 A at 250 V AC / 30 V DC (resistive)
Mechanical Operations 100,000 cycles minimum
Electrical Operations 50,000 cycles minimum at rated load
Cover / Body Transparent polycarbonate dust cover
Pin Footprint Compatible with Omron G2R / Finder 55.34 / HF115F sockets
Mounting PCB or standard 6-pin DIN-rail socket
Stock Status In stock — quote within 24 hours at Moritta@KOEED.COM

The HL3-2A-12S slots cleanly into the same PCB hole pattern and socket bases as the legacy Handouk HF115F family, which is one of the reasons it has become a common industrial relay pick on Chinese-built control boards. The transparent cover lets maintenance staff see contact state at a glance — useful when you are chasing an intermittent fault in the field.

2. Application Scenarios / Where It Fits

A 12 V DC DPDT relay with a 5 A contact envelope is the workhorse component for signal-level switching in panel builders’ sub-assemblies, on PLC digital output backplanes, and inside machine OEM enclosures. Across the nine brands KOEED covers — Allen-Bradley, Siemens, Mitsubishi, Omron, Fanuc, Schneider, Yaskawa, Panasonic and KEYENCE — this size class of relay is found in essentially every factory environment where a low-power digital output has to drive a higher-power load.

  • PLC digital output expansion boards — used as the electromechanical stage after a 24 V DC PLC output (derated to 12 V DC where the system uses 12 V intermediate rails) on Allen-Bradley 1762/1769, Siemens S7-200/S7-1200, and Mitsubishi MELSEC FX racks.
  • Automotive 12 V control panels — battery-direct switching of horns, lamps, fuel pumps, wiper motors, seat heaters and similar loads in test rigs and after-market harnesses.
  • Security & access-control systems — driving magnetic locks, sirens and strobe lights from 12 V DC alarm panels where DPDT contacts are required to break both legs.
  • HVAC and building-automation panels — switching fan contactors, damper actuators and 24 VAC zone valves from low-power thermostats and BMS controllers.
  • Vending, washing-machine and white-goods control boards — a classic location for the HL3 footprint because the transparent cover survives high-humidity wash-down better than open-frame relays.
  • Industrial power supplies and battery chargers — used as the main on/off element and as a transfer relay between primary AC and backup DC sources.
  • Audio equipment and test instruments — signal routing and speaker-protection duties where a DPDT contact is required.

If you are working with Fanuc CNC I/O Link blocks, Yaskawa MP controller break-out boards, or Schneider Modicon M340 discrete output bases, the HL3-2A-12S typically drops in on the same 6-pin socket and the same wiring diagram, which makes it a useful emergency-replacement part to keep in the spares cabinet.

3. Integration & Wiring Notes

Wiring a Handouk HL3-2A-12S into an existing panel is normally a five-minute job, but it pays to confirm the pin-out against the data-sheet for the specific build revision you have on the bench. The general convention is the same one used by the Omron G2R, Finder 55.34 and HF115F families, which means you can usually re-use the existing socket and wiring harness without rework.

Pin 13 & 14 (coil) Apply 12 V DC across pins 13 (+) and 14 (−). Observe polarity — a reverse-polarised coil will not pick up reliably and may overheat.
Pins 9, 12 (common / Form A) First contact set — 12 = common, 9 = normally open, pin between 12 and 9 closes when energised.
Pins 4, 5, 1 (common / Form B) Second contact set — 4 = common, 5 = normally open, 1 = normally closed. With the coil de-energised, 4 is tied to 1; when energised, 4 is tied to 5.
Snubber (inductive loads) Add an RC snubber (100 Ω + 0.1 µF) or a flyback diode across the load to extend contact life on solenoid, motor and transformer switching.
Surge protection on coil Place a 1N4007 diode (cathode to +) across pins 13/14 if the relay is driven directly from a transistor or SSR output.

When you are ladder-logic-driving this relay from a CompactLogix or S7-1200 output, remember the PLC output typically sources 24 V DC, not 12 V DC. The cleanest approach is to add a small 24 V-to-12 V DC dropper resistor (~120 Ω, 2 W) in series with the coil, or to use a 12 V DC regulated tap from the panel PSU. If you are unsure about the polarity or the load rating, the PLC engineering toolkit has a coil-current calculator that will let you sanity-check the design before commissioning.

4. Installation & Commissioning Tips

Whether you are building a new panel or repairing an older one, a few habits will keep the HL3-2A-12S in service for the full 50,000 electrical cycles Handouk rates it for. The points below are the ones our applications team walks customers through most often when the relay is being deployed next to Omron, Panasonic and KEYENCE controllers on the same DIN rail.

  • Confirm the footprint before power-on. The HL3 series shares a 6-pin layout with several other Chinese OEM relays, but the pinning is not identical to every clone. Always trace pins 13/14 to the coil with a multimeter before you apply voltage.
  • Mind the ambient temperature. Rated for 0–55 °C operation, the relay should be mounted clear of heat sinks, transformer cores and other relays that are continuously energised. Keep a minimum of 10 mm air gap above and below the socket.
  • Torque the socket screws correctly. 0.5–0.6 N·m is the typical range for the M3 socket terminals. Over-tightening will crack the polycarbonate base and the failure will not show up until the panel is already on site.
  • Use a retention clip or spring. The transparent cover does not lock the relay into the socket. A wire clip or the manufacturer’s plastic retainer is essential on vibrating machinery (CNC, compressor, conveyor).
  • Add a visible label. A printed tag with the coil voltage and the contact rating makes future maintenance faster and prevents a 24 V coil being plugged into a 12 V circuit by mistake.
  • Test under load, not just no-load. A relay that clicks happily on the bench can fail to make contact on a real inductive load. Always verify with the actual motor, solenoid or lamp installed.
  • Stock a small quantity of spares. Because the HL3-2A-12S uses the same socket and pin pattern as the older HF115F line, panels built in the 2010s can usually be repaired in minutes by swapping the relay itself.

If you are deploying the HL3-2A-12S alongside Mitsubishi FX-series bases or Fanuc I/O Link breakouts, a final visual check is worthwhile: the relay’s blue Handouk label should face the same direction as the rest of the row so the wiring remains consistent during the next service interval.

5. Procurement, Warranty & Lead Time

KOEED keeps the Handouk HL3-2A-12S on the shelf in single-piece and bulk pack quantities. Pricing follows our standard B2B quote-within-24-hours model — send your part list to Moritta@KOEED.COM and we will come back with current stock, lead time and a unit price on the next business day. Worldwide shipping is arranged through DHL, FedEx or UPS, and quotes can include the full BOM if you are also sourcing Allen-Bradley, Siemens, Schneider, Yaskawa or any of the other brands in our matrix alongside this relay.

Pricing Model B2B RFQ — no fixed online price. Bulk quantities attract tiered discounts.
Quote Turnaround Within 24 hours on business days — email Moritta@KOEED.COM.
Lead Time In-stock units ship within 1–3 business days. Larger orders confirmed in the quote.
Shipping DHL / FedEx / UPS worldwide — account options available for repeat customers.
Warranty 12-month replacement warranty against manufacturing defect from date of shipment.
Authenticity Sourced direct from the Handouk authorised channel via our China sourcing company network. Batch and date-code traceable on request.
Returns Covered under our standard return policy.

For full BOM quotes — mixing the HL3-2A-12S with PLC CPUs, servo drives, HMIs, sensors and other parts from the KOEED catalogue — use the Create a Quote form or email Moritta@KOEED.COM directly with your instrument list. Our sourcing desk will consolidate stock, lead time and freight into a single line-item response.

Need this relay or a full BOM?

Send your part list to Moritta@KOEED.COM and get availability & price within 24 hours.

Request a Quote →

Looking for more in the same series?

Browse Handouk Relays →

> Need to size a coil circuit or look up error codes?

Try the KOEED free online PLC toolset.

Open PLC Hex to Float Converter

About Koeed Automation

Expert Supply Solutions for Global Industrial Electronics

At Koeed.com, we are professional architects of the industrial electronics supply chain. We specialize in providing high-performance PLCs, HMIs, Servo Motors, Drives, and Converters to ensure that modern manufacturing operations remain efficient, reliable, and future-proof in 2026’s competitive landscape.

🛡️ Certified Quality

We source only 100% authentic industrial hardware from global category leaders. Every component undergoes a rigorous verification process to meet Industry 4.0 reliability standards.

⚙️ Engineering Domain

Our experts provide more than just parts; we offer technical insight. We assist in complex product selection and compatibility audits for both legacy system upgrades and new installations.

🌐 Rapid Global Logistics

Time is money in industrial automation. Our optimized supply network ensures that critical components reach your facility quickly, significantly reducing unplanned downtime and operational loss.

Strategic Global Portfolio: Siemens, Omron, FANUC, Schneider Electric, Mitsubishi, Yaskawa, Allen-Bradley, and other elite industrial brands.

Supporting your vision for a smarter, more efficient industrial future.

Special Reminder

Important

If you have any questions about product information and prices, please feel free to contact us by email or WhatsApp. We will respond quickly.

  • Business Days Only (Monday through Saturday)
  • It takes up to 10 days from the time of ordering (excluding Saturdays and Sundays) to the time of delivery to your designated location. Worldwide delivery.
  • Within 3 days after placing the order, we will send you photos and videos of the product via email or WhatsApp for confirmation

International shipping - items may be subject to customs processing depending on the item's customs value.
Sellers declare the item's customs value and must comply with customs declaration laws.
As the buyer, you should be aware of possible:

  • Delays from customs inspection.
  • Import duties and taxes which buyers must pay.
  • Brokerage fees payable at the point of delivery.

Shipping Policy

Global Delivery

We ship to customers all over the world. Our primary logistics providers are DHL, UPS, TNT, FedEx, and EMS.

Processing Time

All orders are processed within 72 hours of purchase. Please note that this applies to business days only.

Shipping Rates & Delivery Estimates

Shipping charges for your order will be calculated and displayed at checkout. Delivery estimates are within 7-14 days. Please note that these shipping times are only estimates and unfortunately, cannot be guaranteed.

Shipment Confirmation & Order Tracking

You will receive a Shipment Confirmation email once your order has shipped containing your tracking number(s). The tracking number will be active within 24 hours.

Customs, Duties, and Taxes

Please note, international shipping services do vary from country to country. To find out the exact services that are available, please put in your full address at checkout. Shipping internationally does mean that you may be required to pay customs and import taxes. All international customers are responsible for the customs rates within their own country. For further information, we recommend contacting your local customs office.

Damages

We take every reasonable precaution to ensure that products are not damaged. If the item is damaged in transit, please immediately contact us. We are not liable for any products damaged or lost during shipping. If you received your order damaged, please contact the shipment carrier to file a claim. Please save all packaging materials and damaged goods before filing a claim.

Force Majeure

When encountering with force majeure, the processing of orders will be delayed. Nevertheless, it is ensured that your order will be processed in a fast manner when weather permits.

Address Verification

Please verify you have the correct shipping address on your order PRIOR to making payment as this is the address we will ship to.

Return Policy

For more information, visit our Return Policy page.

International shipping - items may be subject to customs processing depending on the item's customs value.

Sellers declare the item's customs value and must comply with customs declaration laws.
As the buyer, you should be aware of possible:
• Delays from customs inspection.
• Import duties and taxes which buyers must pay.
• Brokerage fees payable at the point of delivery.

Contact Us

If you have any questions about your order, please contact us at moritta@koeed.com.

Return Policy

Return and Refund Policy

We want you to be completely satisfied with your purchase on our store. If for any reason you are not entirely satisfied, we're here to help!

Returns

You have a generous 30 calendar days to return an item from the date you received it. To be eligible for a return, ensure the item is in its original, unworn, and unused condition with tags and packaging intact. Retain your receipt or proof of purchase for eligibility. Please note that certain items are non-returnable like perishables, custom products, personal care goods, hazardous materials, flammable liquids, and gases. Reach out for clarifications on specific items.

Return Process

Commence the return process by reaching out to us at moritta@koeed.com. Upon approval, we will furnish you with a return shipping label and detailed instructions for dispatching your package. Unnotified returns will not be accepted.

Damages and Issues

Kindly review your order upon delivery. Notify us promptly if it arrives defective, damaged, or incorrect. We will address the matter swiftly.

Exchanges

Facilitate a swift exchange by returning the original item once approved and making a new purchase.

EU 14-Day Cooling Off Period

EU-bound shipments allow a 14-day cancellation or return period without justification. Conditions mirror standard returns.

Refunds

Upon receiving and inspecting your return, we’ll inform you of the refund status. Approved refunds are automatically processed within 10 business days via the initial payment method. Allow time for financial institutions to finalize the refund. For delays exceeding 15 business days post-approval, contact us at moritta@koeed.com.

Shipping

You will be responsible for paying for your own shipping costs for returning your item. Shipping costs are non-refundable. If you receive a refund, the cost of return shipping will be deducted from your refund.

Contact Us

If you have any questions on how to return your item to us, feel free to contact us at moritta@koeed.com.

Related manufacturers