MKS 103450010 Pirani Vacuum Gauge — Thermal-Conductivity Pressure Sensor
MKS Instruments · Pirani / HPS® Series · Vacuum Sensor · Worldwide Shipping
The MKS 103450010 is a Pirani-type thermal-conductivity vacuum pressure sensor used to
monitor rough and medium vacuum in process tools, load locks, transfer chambers, R&D vacuum systems
and analytical instruments. It is widely deployed in semiconductor fabs, photovoltaic lines, vacuum
metallurgy, freeze-drying and mass-spectrometer inlets where reliable low-pressure feedback is critical
to Allen-Bradley ControlLogix,
Siemens SIMATIC S7 and
Mitsubishi MELSEC
process controllers.
KOEED sources genuine MKS / HPS® Pirani transducers and ships them worldwide with full documentation.
Send your instruments list to
Moritta@KOEED.COM
for a 24-hour quote.
1. Key Technical Specifications & Overview
A Pirani gauge works on the thermal-conductivity principle: a heated filament loses heat to the surrounding
gas at a rate that depends on pressure. As pressure falls, fewer gas molecules carry heat away, the
filament temperature rises, and the change in resistance is correlated to absolute pressure. This makes
the 103450010 the standard workhorse for the 10−4 mbar to 103 mbar range.
| Brand |
MKS Instruments (USA) / HPS® product line |
| Part Number |
103450010 |
| Sensor Type |
Pirani vacuum gauge (thermal-conductivity) |
| Measurement Range |
10−4 mbar to 103 mbar (typical Pirani span) |
| Measurement Principle |
Heated filament — resistance varies with gas thermal conductivity |
| Vacuum Flange |
NW25 / KF25 (industry-standard Pirani mounting) |
| Compatible Controllers |
MKS PDR-2000, Granville-Phillips 275 / 376 / 390, MKS 901P, 937B |
| Output Signal |
Analog pressure output to controller; controller exposes 0–10 V or RS-232 / RS-485 to host PLC |
| Typical Industries |
Semiconductor, photovoltaic, vacuum metallurgy, R&D, analytical instruments |
| Stock Status |
In stock — quote within 24 hours at
Moritta@KOEED.COM
|
2. Application Scenarios — Where It Fits
The MKS 103450010 is specified wherever a process step needs a clean, repeatable low-pressure reference
signal. In production environments, that signal is fed into a plant-level
Allen-Bradley,
Omron or
Schneider Modicon
controller for interlock logic, recipe control, and historian logging. Typical deployments include:
- Semiconductor fab load locks and transfer chambers on
Siemens SIMATIC /
Mitsubishi MELSEC
platforms
- Photovoltaic and thin-film deposition tools interlocked with
Fanuc handlers and
Yaskawa servo
axes
- Vacuum oven, vacuum furnace and brazing furnaces with recipe control on
Panasonic FP or
KEYENCE PLCs
- Freeze dryers, mass-spectrometer inlets, leak detectors and analytical instrument front-ends
- Coating, sputtering and PVD / PECVD process tools where vacuum ramps are part of the recipe
- Hard-to-find replacement in legacy MKS / HPS® Pirani installations where the OEM sensor is EOL
3. Integration & Wiring Notes
The 103450010 is the sensor head only — it must be paired with a compatible MKS controller
(PDR-2000, 901P, 937B, or a Granville-Phillips 275 / 376 / 390) that supplies the bridge excitation,
linearization and analog output. The notes below cover the integration decisions that most often cause
commissioning delays.
-
Sensor cable: use the OEM MKS shielded cable assembly, not a generic twisted pair.
Cable length contributes to the bridge balance and to noise pickup on a heated filament.
-
Controller pairing: confirm the controller firmware / setpoint table recognizes the
103450010 P/N; legacy PDR-2000 units often need a sensor-type jumper or EPROM update.
-
Analog output to PLC: the controller typically exposes 0–10 V or 4–20 mA.
Wire to an analog input module and convert with the
PLC Analog Calculator
to engineering units (mbar / Pa).
-
Digital output: newer MKS controllers support RS-232 / RS-485 setpoint queries;
map readings into the PLC scan via Modbus RTU when exposed.
-
Ground and shielding: bond the sensor body to chamber ground at one point only;
route the signal cable away from VFD-driven servo drives (Fanuc, Yaskawa) to avoid coupled noise.
-
Vacuum-side cleanliness: Pirani filaments are sensitive to pump oil, photoresist
outgassing and process deposits. Mount vertically with the port down where possible and budget for
periodic filament replacement in high-cycle processes.
For sensor / controller diagnostics, see the
PLC Error Code Database
and the
AI Diagnostic Tool
for 24/7 help interpreting a noisy or stuck Pirani reading.
4. Installation & Commissioning Tips
A clean installation dramatically extends Pirani service life. The MKS 103450010 uses a standard NW25 /
KF25 flange, so it mates with most European-style vacuum piping found in semiconductor, R&D and
analytical tools. Treat the filament as a consumable — it is replaceable on the MKS platform, not
on the tool side.
- Vent the chamber to atmospheric pressure before opening the KF clamp; venting under partial vacuum
can suck particulates back into the sensor.
- Use a fresh centering ring (FKM / Viton® or Kalrez® for aggressive chemistries) and a new
clamp; do not re-use a nicked ring on a high-vacuum seal.
- After pump-down, run the controller’s automatic zero / atmosphere adjustment sequence with the
gauge isolated from the chamber at full vacuum and at dry N2 atmosphere, respectively.
- Log a baseline reading at atmosphere and at crossover to the next-stage gauge (e.g. cold cathode or
Baratron®) so the recipe engineer has a known-good reference curve.
- Validate the analog input wiring end-to-end with a hand-held calibrator before energizing the
chamber heaters — many “vacuum drift” tickets in
factory automation
are actually analog-input scaling errors in the PLC.
- Add the gauge to the preventive-maintenance schedule and keep a spare 103450010 on the shelf if
downtime is expensive.
5. Procurement, Warranty & Lead Time
MKS 103450010 Pirani gauges ship in original MKS / HPS® packaging with traceable lot numbers and
factory calibration certificates. KOEED is an independent multi-brand industrial-automation distributor
(not an OEM subsidiary) — we source genuine MKS sensors through our
China sourcing
network and re-test on receipt.
-
RFQ turnaround: most quotes return within 24 hours on business days — email
Moritta@KOEED.COM
with the part number, quantity and destination country.
-
BOM quotation: send a full instrument list (vacuum gauges, controllers, PLCs, servo
drives) and we quote the lot — useful for fabs running mixed-brand lines.
-
Lead time: typically 3–7 business days for in-stock items, longer for factory
drops. Express options on request.
-
Shipping: DHL, FedEx, UPS or air freight worldwide (per the product page title
convention) — see the
Shipping Policy.
-
Warranty: 12-month limited warranty against manufacturing defects; warranty does
not cover filament burnout from contamination or operation outside the rated pressure range.
-
Hard-to-find / EOL: if the 103450010 is end-of-life at the OEM, ask us — the
real-time sales
records show what we have shipped recently, and the
AI Diagnostic Tool
can suggest a drop-in alternative.
For related controllers and accessories, see the
MKS Instruments and
vacuum sensor
collections, and follow our
Daily PLC News
for end-of-life notices on MKS / HPS® P/Ns.
Need this Pirani gauge or a full vacuum-instrument BOM?
Send your part list to Moritta@KOEED.COM and get availability + price within 24 hours.