Siemens 6SL3352-6TE35-0AA3 SINAMICS S120 Line Module
Siemens · SINAMICS S120 · Active / Smart Line Module · In stock
The 6SL3352-6TE35-0AA3 is a Siemens SINAMICS S120 chassis-format line module from the 6SL3352 family, used as the line-side rectifier that feeds the common DC bus of a multi-axis S120 drive system. It belongs to the same SINAMICS S120 / S150 / G150 power-module family we keep alongside Allen-Bradley PowerFlex, Mitsubishi MR-J, Yaskawa Sigma-7, and Schneider Altivar drive spares, so it fits a multi-brand cabinet where S120 drives share a backplane with PLCs from Omron, Panasonic FP, Fanuc, or KEYENCE vision systems.
The "6TE" position in the MLFB (Machine-Readable Product Designation) identifies an active / smart line-side converter block, while "35" indicates the current frame size. The exact kW rating and whether the unit is a Basic Line Module (BLM), Smart Line Module (SLM) or Active Line Module (ALM) should be confirmed from the nameplate on the front bezel before substitution. For multi-axis machines such as printing presses, packaging lines, paper machines, extruders, machine tools, cranes and large elevators, this module typically sits at the head of a SINAMICS S120 line-up as the regenerative or non-regenerative DC-bus supply. Sourcing from KOEED lets you keep one BOM supplier for the whole cabinet — send the full part list to Moritta@KOEED.COM and we will quote availability and price within 24 hours.
1. Key Technical Specifications
| Brand |
Siemens |
| Series |
SINAMICS S120 (6SL3352 chassis-format line module) |
| Part Number (MLFB) |
6SL3352-6TE35-0AA3 |
| Module Type |
Active / Smart Line Module (ALM / SLM) — please confirm from nameplate |
| Frame Size |
Size 35 (within 6SL3352 family) — kW class typically 10–30 kW at 400 V |
| Line Supply Voltage |
3-phase 380–480 V AC, 50/60 Hz (typical SINAMICS S120 line-module range) |
| DC Bus Output |
Common DC bus 510–720 V DC for downstream S120 Motor Modules |
| Cooling Method |
Internal forced air cooling (built-in fan) |
| Control / Communication |
DRIVE-CLiQ port to CU320-2 or SINUMERIK controller, status LEDs on front |
| Typical Application |
DC-bus supply for multi-axis SINAMICS S120 drive line-ups in machine tools, packaging, paper, printing, extruders, cranes and elevators |
| Stock Status |
In stock — quote within 24 hours at Moritta@KOEED.COM
|
Note: power class (kW), ALM vs SLM firmware and connector layout must be cross-checked against the unit’s nameplate. Send a clear front-panel photo to Moritta@KOEED.COM and we will confirm the exact variant before shipping.
2. Application Scenarios — Where It Fits
A SINAMICS S120 line module is the single point of common-DC-bus conversion in a cabinet, so it shows up wherever a machine has several coordinated axes drawing from one shared DC link. Typical installations include:
- Printing and converting machines — multi-motor webs with dancer and tension control, often paired with a SINAMICS S120 Motor Module per axis
- Packaging lines — form-fill-seal, labelling, palletising and wrapper sections, typically integrated with an Allen-Bradley ControlLogix or Omron NJ/NX PLC for line coordination
- Paper machines and corrugators — sectional drives where regenerative energy from the unwinder must be returned to the line, which is exactly why an Active or Smart Line Module is preferred over a passive diode rectifier
- Plastics extruders and rubber calendering — screw + haul-off + winder, often controlled by Siemens SIMATIC S7-1500 or Mitsubishi iQ-R
- Machine tools — lathes, milling centres and grinders using SINUMERIK 840D sl with multiple S120 axes on a common DC bus
- Cranes, hoists and elevators — vertical-motion applications where regenerative braking energy from the lowering motion is fed back through the line module
- Test stands and laboratory drive rigs — any multi-motor dynamometer or e-machine test bed that benefits from a shared DC bus
Because KOEED also stocks Fanuc spindle amplifiers, Yaskawa Sigma-7 and Schneider Lexium servo spares, mixed-brand cabinets can be quoted in a single BOM — see the full brand index for what we cover side-by-side with Siemens.
3. Integration & Wiring Notes
Wiring a SINAMICS S120 line module is straightforward if the cabinet layout follows the Siemens SINAMICS S120 manual, but a few points are commonly missed on retrofits and on cross-brand cabinets:
-
Line-side power wiring: 3-phase 380–480 V AC L1/L2/L3 to the input terminal block of the line module. The PE conductor must be bonded to the cabinet ground bar with the shortest possible pigtail; high-leakage line modules require a reinforced PE per the manual.
-
DC bus link: the DC link bars (DC+ / DC−) on top of the module are the common bus to every downstream Motor Module. Verify bus-bar gauge and tightening torque when retrofitting older cabinets, especially when adding a third-party drive into the same DC link.
-
DRIVE-CLiQ topology: connect the line module’s DRIVE-CLiQ port to the CU320-2 control unit (or a SINUMERIK NCU) with the supplied cable. The line module must be addressed first in the automatic topology, before any Motor Module.
-
Braking / regeneration: for ALM variants, no external braking resistor is required; for SLM and BLM variants, a Brake Module + resistor may be required if the system cannot absorb regenerated energy. Confirm the topology on the nameplate before ordering.
-
24 V control power: SINAMICS S120 chassis modules require a separate 24 V DC supply for the control electronics; do not back-feed from the DC bus, and keep the 24 V return isolated from cabinet ground at a single point.
-
EMC and line filter: for CE conformity, fit the recommended Siemens line filter upstream of the line module, and use shielded motor cables on every Motor Module downstream.
-
Cross-brand PLC integration: if the line-up is commanded by an Allen-Bradley, Mitsubishi, Omron, Panasonic, Fanuc, Schneider or Yaskawa PLC, use PROFINET, EtherNet/IP, EtherCAT or Modbus TCP as required by the higher-level controller — the SINAMICS S120 control unit supports all four.
4. Installation & Commissioning Tips
-
Mounting clearance: leave at least 100 mm above and below the module for airflow. The internal fan draws air bottom-to-top; blocking the inlet is the single most common cause of F30002 / F30003 overtemperature faults in the field.
-
Torque and bus-bar preparation: clean the DC-bus mating surfaces with a non-abrasive pad and apply the contact aid specified by Siemens before joining the bus bars. Loose bus connections cause voltage spikes that can knock the line module into F30001 / F30007 on first power-up.
-
First-time commissioning with STARTER / Startdrive: load the SINAMICS S120 firmware that matches the CU320-2 firmware, then run an "automatic configuration" so the line module is detected and addressed before the Motor Modules. A mis-ordered topology is the typical reason the line module is reported as "missing" in the project tree.
-
Nameplate verification before power-on: compare the MLFB, hardware revision and rated current printed on the front bezel with the BOM. Mixing a 400 V line module into a 690 V cabinet is a destructive mistake — confirm the input class before energising.
-
Spare-staging for legacy machines: older S120 chassis line modules are increasingly hard to source through authorised channels. KOEED keeps the 6SL3352 family and the wider 6SN11xx / 6SL3xxx SIMODRIVE / SINAMICS range in active stock for service engineers, and our AI Diagnostic Tool can identify the correct line module from a nameplate photo if the original paperwork is missing.
-
Engineering notes for multi-axis retrofit: when replacing a faulted line module in a working cabinet, record the firmware version of the existing CU320-2 and the active topology XML before removing the old unit — importing the same topology into the new module avoids a full recommissioning cycle.
5. Procurement, Warranty & Lead Time
KOEED holds 6SL3352-6TE35-0AA3 in active stock and ships worldwide from our Shenzhen / Hong Kong dual-base operation. Pricing follows the B2B RFQ model — we do not publish a fixed unit price, and we do not run promotional discounts. To receive an accurate quote, please send the following to Moritta@KOEED.COM:
- The exact MLFB (6SL3352-6TE35-0AA3) plus any cross-references already on the BOM
- A clear nameplate photo so we can confirm the kW class, ALM vs SLM and the connector / firmware variant
- Quantity, target destination country and required delivery window
- The rest of the cabinet BOM if you would like a single combined quote — we routinely ship a SINAMICS S120 line module together with SINAMICS S120 Motor Modules, SIMATIC S7-1500 CPUs, SIMATIC HMI panels and the matching Siemens Sirius contactors
Every 6SL3352-6TE35-0AA3 we ship is inspected, function-tested on a SINAMICS S120 test rig and packaged in anti-static + foam-lined cartons. Standard warranty terms are stated in the order confirmation; extended 12-month and 24-month warranty options are available for mission-critical spares. Worldwide shipping is dispatched via DHL / FedEx / UPS with full export documentation. Quote turnaround is 24 hours on business days, and the same Moritta@KOEED.COM inbox is monitored 7 days a week for urgent breakdown cases. If the unit is no longer available in your region, our AI Diagnostic Tool can suggest functionally equivalent SINAMICS S120 line modules or cross-brand alternatives from Allen-Bradley PowerFlex, Yaskawa, Mitsubishi, Schneider, Fanuc, Omron, Panasonic or KEYENCE when Siemens stock is constrained. Browse the full Siemens drive and PLC catalogue or send a multi-line BOM through the Create a Quote form.
Need a Siemens 6SL3352-6TE35-0AA3 or a full S120 BOM?
Send your part list to Moritta@KOEED.COM and get availability + price within 24 hours.
Request a Quote →
> Not sure if this is the right line module?
Send a nameplate photo to our AI Diagnostic Tool and we will identify the exact MLFB and kW class.
Open the AI Diagnostic Tool